Uncooled two-microbolometer stack for long wavelength infrared detection

被引:9
作者
Abdullah, Amjed [1 ]
Koppula, Akshay [1 ]
Alkorjia, Omar [1 ]
Almasri, Mahmoud [1 ]
机构
[1] Univ Missouri Columbia, Elect & Comp Engn Dept, Columbia, MO 65211 USA
关键词
THIN-FILMS; 1/F NOISE; MICROBOLOMETERS; SENSOR; MULTICOLOR; BOLOMETER; ABSORBERS; DESIGN; CAMERA;
D O I
10.1038/s41598-023-30328-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We have investigated an uncooled infrared (IR) detector utilizing a dual level architecture. This was achieved by combining two-microbolometer stack in the vertical direction to achieve high IR absorption over two distinct spectral windows across the long wavelength infrared region (LWIR). In addition, we have studied amorphous silicon germanium oxide (SixGeyO1-x-y) as an IR sensitive material, and metasurface to control IR absorption/reflection in interaction with standard Fabry-Perot cavity. The bottom microbolometer uses a metasurface to selectively absorbs a portion of the spectrum and reflects radiation outside this window range. At the same time, the top microbolometer uses a conventional Fabry-Perot resonant cavity to absorb a different portion of the spectrum and transmit any unabsorbed radiation outside this window. This device can be used to measure the absolute temperature of an object by comparing the relative signals in the two spectral bands. The spectral responsivity and detectivity, and thermal response time were > 10(5) V/W, > 10(8) cm Hz(1/2)/W, and 1.13 ms to filtered blackbody infrared radiation between (2-16) mu m. The microbolometer voltage noise power spectral density was reduced by annealing the microbolometers in vacuum at 300 degrees C.
引用
收藏
页数:12
相关论文
共 67 条
[31]  
Jung J.-Y., 2015, IEEE Photonics J, V7, P1
[32]  
Keskin S., 2012, SPIE P, V83531, P461
[33]   Infrared imager employing 160x120 pixel uncooled bolometer array [J].
Kruse, P ;
Dodson, R ;
Anderson, S ;
Kantor, L ;
Knipfer, M ;
McManus, T .
INFRARED TECHNOLOGY AND APPLICATIONS XXIV, PTS 1-2, 1998, 3436 :572-577
[34]  
Kruse P.W., 1997, SEMICONDUCT SEMIMET, V47, P17, DOI DOI 10.1016/S0080-8784(08)62688-5
[35]   Two-color thermal detector with thermal chopping for infrared focal-plane arrays [J].
Leonov, VN ;
Butler, DP .
APPLIED OPTICS, 2001, 40 (16) :2601-2610
[36]   Overview of DRS uncooled VOx infrared detector development [J].
Li, Chuan ;
Han, C. J. ;
Skidmore, George .
OPTICAL ENGINEERING, 2011, 50 (06)
[37]  
Liu T., 2016, SPIE P, V98191, P5
[38]   Multispectral imaging MWIR sensor for determination of spectral target signatures [J].
Ljungberg, P ;
Kihlen, RG ;
Lundqvist, SH ;
Potet, P ;
Berrebi, S .
INFRARED TECHNOLOGY AND APPLICATIONS XXIII, PTS 1 AND 2, 1997, 3061 :823-832
[39]   Low frequency noise in hydrogenated p-type amorphous silicon thin films [J].
Lopes, V. C. ;
Syllaios, A. J. ;
Littler, C. L. .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 2017, 459 :176-183
[40]  
Mizrahi U., 2010, SPIE P, V76600, P285