Effect of Atomic-Layer-Deposited Hydroxyapatite Coating on Surface Thrombogenicity of Titanium

被引:3
作者
Abushahba, Faleh [1 ,2 ,3 ,4 ]
Areid, Nagat [1 ]
Kylmaeoja, Elina [5 ]
Holopainen, Jani [6 ]
Ritala, Mikko [6 ]
Hupa, Leena [7 ]
Tuukkanen, Juha [5 ]
Naerhi, Timo [1 ,8 ]
机构
[1] Univ Turku, Inst Dent, Dept Prosthet Dent & Stomatognath Physiol, Turku 20520, Finland
[2] Univ Turku, Dept Biomat Sci, Turku 20520, Finland
[3] Univ Turku, Inst Dent, Turku Clin Biomat Ctr, TCBC, Turku 20520, Finland
[4] Libyan Int Med Univ LIMU, Fac Dent, Dept Restorat Dent & Periodontol, 339P62Q, Benghazi, Libya
[5] Univ Oulu, Med Res Ctr, Dept Anat & Cell Biol, Inst Canc Res & Translat Med, FIN-90014 Oulu, Finland
[6] Univ Helsinki, Dept Chem, Helsinki 00014, Finland
[7] Abo Akad Univ, Johan Gadolin Proc Chem Ctr, Turku 20500, Finland
[8] Wellbeing Serv Cty Southwest Finland, Turku 20521, Finland
关键词
ALD; platelets adhesion; blood coagulation; hydroxyapatite coating; titanium; PLATELET INTERACTIONS; ADHESION; CELL; COAGULATION; INVITRO; ENERGY;
D O I
10.3390/coatings13101810
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study aimed to evaluate the surface characteristics of a nanocrystalline hydroxyapatite coating made through atomic layer deposition (ALD-HA) on titanium surfaces and to investigate its effect on blood coagulation and platelet adhesion. Grade 2 square titanium discs (0.7 cm, 1 mm thick) were used (n = 108). Half of the substrates (n = 54) were coated with ALD-HA, and the other half were used as the non-coated control. Surface free energy (SFE), contact angle (CA), surface roughness (Ra), and chemical composition were evaluated. Blood thrombogenic properties were assessed on ALD-HA and non-coated surfaces using the kinetic clotting time method. The platelets' adhesion and morphology were also evaluated. The ALD-HA-coated surfaces demonstrated significantly higher polar SFE (p < 0.001) and lower CA (p < 0.001) values compared to the non-coated surfaces. In addition, the surface roughness was significantly lower for the ALD-HA (p < 0.001) than for the non-coated surfaces. Platelets adhered to both surfaces; however, there was variability in platelet morphologies in different areas with higher platelet density on the ALD-HA surfaces. There was no significant difference in the overall absorbance values of the hemolyzed hemoglobin for both substrates, and the total clotting time was achieved at 60 min. It can be concluded that the ALD-HA coating of titanium can enhance surface wettability, increase surface free energy, and support blood coagulation and platelet adhesion.
引用
收藏
页数:12
相关论文
共 42 条
[1]   Blood and fibroblast responses to thermoset BisGMA-TEGDMA/glass fiber-reinforced composite implants in vitro [J].
Abdulmajeed, Aous A. ;
Walboomers, X. F. ;
Massera, Jonathan ;
Kokkari, Anne K. ;
Vallittu, Pekka K. ;
Narhi, Timo O. .
CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (07) :843-851
[2]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[3]   Atomic layer deposition on dental materials: Processing conditions and surface functionalization to improve physical, chemical, and clinical properties - A review [J].
Astaneh, Sarah Hashemi ;
Faverani, Leonardo P. ;
Sukotjo, Cortino ;
Takoudis, Christos G. .
ACTA BIOMATERIALIA, 2021, 121 :103-118
[4]   Adhesion and mechanical properties of nanocrystalline hydroxyapatite coating obtained by conversion of atomic layer-deposited calcium carbonate on titanium substrate [J].
Avila, Inari ;
Pantchev, Konstantin ;
Holopainen, Jani ;
Ritala, Mikko ;
Tuukkanen, Juha .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2018, 29 (08)
[5]   Engineering biocompatible implant surfaces Part I: Materials and surfaces [J].
Bauer, Sebastian ;
Schmuki, Patrik ;
von der Mark, Klaus ;
Park, Jung .
PROGRESS IN MATERIALS SCIENCE, 2013, 58 (03) :261-326
[6]  
BhavanChand Y., 2012, Int. J. Prosthodont. Restor. Dent, V2, P136
[7]   Enhanced bone apposition to a chemically modified SLA titanium surface [J].
Buser, D ;
Broggini, N ;
Wieland, M ;
Schenk, RK ;
Denzer, AJ ;
Cochran, DL ;
Hoffmann, B ;
Lussi, A ;
Steinemann, SG .
JOURNAL OF DENTAL RESEARCH, 2004, 83 (07) :529-533
[8]   A comparison of bone remodelling around hydroxyapatite-coated, porous-coated and grit-blasted hip replacements retrieved at post-mortem [J].
Coathup, MJ ;
Blunn, GW ;
Flynn, N ;
Williams, C ;
Thomas, NP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (01) :118-123
[9]  
Davies John E, 2003, J Dent Educ, V67, P932
[10]   CONTACT-ANGLE MEASUREMENTS ON HUMAN-ENAMEL - AN INVITRO STUDY OF INFLUENCE OF PELLICLE AND STORAGE PERIOD [J].
DEJONG, HP ;
VANPELT, AWJ ;
ARENDS, J .
JOURNAL OF DENTAL RESEARCH, 1982, 61 (01) :11-13