One-year outcomes in patients undergoing very high-power short-duration ablation for atrial fibrillation

被引:10
|
作者
Solimene, Francesco [1 ]
Strisciuglio, Teresa [1 ,2 ]
Schillaci, Vincenzo [1 ]
Arestia, Alberto [1 ]
Shopova, Gergana [1 ]
Salito, Armando [1 ]
Bottaro, Giuseppe [1 ]
Marano, Giovanni [1 ]
Coltorti, Fernando [1 ]
Stabile, Giuseppe [1 ,3 ,4 ,5 ]
机构
[1] Clin Montevergine, Mercogliano, AV, Italy
[2] Univ Naples Federico II, Dept Adv Biomed Sci, Naples, NA, Italy
[3] Mediterranea Cardioctr, Naples, NA, Italy
[4] Clin San Michele, Maddaloni, CE, Italy
[5] Anthea Hosp, Bari, BA, Italy
关键词
Atrial fibrillation; Pulmonary vein isolation; Very high-power short-duration; Catheter ablation; Radiofrequency ablation; PULMONARY VEIN ISOLATION; RADIOFREQUENCY ABLATION;
D O I
10.1007/s10840-023-01520-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The very high-power short-duration (vHPSD) temperature-controlled ablation (vHPSD) improves the efficiency of pulmonary vein isolation (PVI) procedures.We evaluated the procedural and 12-months outcomes in atrial fibrillation (AF) patients undergoing PVI by means of vHPSD ablation. In patients with AF or atrial tachyarrythmia (AT) recurrence undergoing a redo procedure the durability of the PVI was investigated. Methods Consecutive paroxysmal/persistent AF patients undergoing PVI with the vHPSD ablation strategy (90 W, for 4 s) were enrolled. The rate of PVI, first-pass isolation, acute reconnection, and procedural complications were evaluated. Follow-up examinations and EKG were scheduled at 3,6, and 12 months. In case of AF/AT recurrence, patients underwent a redo procedure. Results Overall, 163 AF patients (29 persistent and 134 paroxysmal) were enrolled. The PVI was reached in 100% of patients (88% at the first pass). The rate of acute reconnection was 2%. The radiofrequency, fluoroscopy and procedural times were respectively 5.5 +/- 1 min, 9 +/- 1 min and 75 +/- 20 min. No death, tamponade nor steam pops occurred; however, 5 patients had vascular complications. The 12-months freedom from AF/AT recurrence was 86% in both paroxysmal and persistent patients. Overall, 9 patients underwent a redo procedure, and in 4 all veins were still isolated, whereas in 5 pulmonary vein reconnections were found. The PVI durability was 78%. No overt clinical complications were observed in the follow-up. Conclusions The vHPSD ablation represents an effective and safe ablation strategy to achieve PVI. The 12-months follow-up showed high freedom from AF/AT recurrence and a good safety profile.
引用
收藏
页码:1911 / 1917
页数:7
相关论文
共 50 条
  • [11] Safety and outcome of very if high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Kottmaier, Marc
    Popa, Miruna
    Bourier, Felix
    Reents, Tilko
    Cifuentes, Jairo
    Semmler, Verena
    Telishevska, Martha
    Otgonbayar, Ulamnemekh
    Koch-Buettner, Katharina
    Lennerz, Carsten
    Bartkowiak, Marcin
    Kornmayer, Marielouise
    Rousseva, Elena
    Brkic, Amir
    Grebmer, Christian
    Kolb, Christoph
    Hessling, Gabriele
    Deisenhofer, Isabel
    EUROPACE, 2020, 22 (03): : 388 - 393
  • [12] The evolution of high-power short-duration atrial fibrillation ablation: "The long slog"
    Winkle, Roger A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (02) : 342 - 344
  • [13] Incidence and predictors of stroke and silent cerebral embolism following very high-power short-duration atrial fibrillation ablation
    Boga, Marton
    Suhai, Ferenc Imre
    Orban, Gabor
    Sallo, Zoltan
    Nagy, Klaudia Vivien
    Szegedi, Levente
    Jokkel, Zsofia
    Csore, Judit
    Osztheimer, Istvan
    Perge, Peter
    Gupta, Dhiraj
    Merkely, Bela
    Geller, Laszlo
    Szegedi, Nandor
    EUROPACE, 2023, 25 (11):
  • [14] High-power short-duration ablation of atrial fibrillation: A contemporary review
    Naniwadekar, Aditi
    Dukkipati, Srinivas R.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (03): : 528 - 540
  • [15] Meta-analysis of high-power short-duration versus cryoballoon ablation for atrial fibrillation
    Lin, Limin
    Huang, Ying
    Huang, Qunying
    Yu, Fuling
    Mao, Yinjun
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (08): : 1013 - 1024
  • [16] Very high-power and short-duration radiofrequency ablation for atrial fibrillation in a Latin American low-volume private center
    Keegan, Roberto
    Garmendia, Francisco
    Gregorietti, Franco
    Urruti, Ricardo
    Onetto, Leonardo
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (6) : 1399 - 1406
  • [17] Meta-Analysis of Pulsed-Field Ablation Versus- High-Power Short-Duration Ablation for Atrial Fibrillation
    Xue, Jun
    Huang, Qunying
    Yu, Fuling
    Mao, Yinjun
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2025, : 180 - 191
  • [18] 50-W vs 40-W During High-Power Short-Duration Ablation for Paroxysmal Atrial Fibrillation
    Costea, Alexandru
    Diaz, Juan Carlos
    Osorio, Jose
    Matos, Carlos D.
    Hoyos, Carolina
    Goyal, Sandeep
    Te, Charles
    D'Souza, Benjamin
    Rastogi, Mohit
    Lopez-Cabanillas, Nestor
    Ibanez, Laura C.
    Thorne, Christopher
    Varley, Allyson L.
    Zei, Paul C.
    Sauer, William H.
    Romero, Jorge E.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2023, 9 (12) : 2573 - 2583
  • [19] High-power, short-duration ablation during Box isolation for atrial fibrillation
    Kumagai, Koichiro
    Toyama, Hideko
    JOURNAL OF ARRHYTHMIA, 2020, 36 (05) : 899 - 904
  • [20] Short and Long-Term Outcomes of Lesion Index-Guided High-Power Short-Duration Approach for Atrial Fibrillation Ablation
    Di Cori, Andrea
    Parollo, Matteo
    Gentile, Francesco
    Pistelli, Lorenzo
    Vitale, Carlo
    Della Volpe, Salvatore
    Santoro, Mario Giannotti
    Mazzocchetti, Lorenzo
    De Lucia, Raffaele
    Canu, Antonio
    Barletta, Valentina
    Grifoni, Gino
    Segreti, Luca
    Bongiorni, Maria Grazia
    Zucchelli, Giulio
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (15)