Biomechanical comparison of three different surgical methods in the surgical treatment of distal tibial metaphyseal fractures. An animal model study

被引:0
作者
Yildirim, Cem [1 ]
Muratoglu, Osman Gorkem [2 ]
Ordu, Samed [3 ]
Ceylan, Hasan [1 ]
Muslu, Duran Can [4 ]
Atlihan, Dogan [5 ]
机构
[1] Cam & Sakura City Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkiye
[2] Istinye Univ, Dept Orthoped & Traumatol, Istanbul, Turkiye
[3] Eskisehir Yunus Emre State Hosp, Dept Orthoped & Traumatol, Eskisehir, Turkiye
[4] Klinikum Dahme Spreewald Achenbach Krankenhaus, Dept Orthoped & Traumatol, Konigs Wusterhausen, Brandenburg, Germany
[5] Haseki Training & Res Hosp, Dept Orthoped & Traumatol, Istanbul, Turkiye
来源
ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY | 2023年 / 29卷 / 10期
关键词
External fixator; locked compression plate; minimal invasive plate osteosynthesis; open tibia fracture; supercutaneus plating; LOCKING COMPRESSION PLATE; DEFINITIVE EXTERNAL FIXATOR; INTERNAL-FIXATION; MANAGEMENT; REDUCTION; SHEEP;
D O I
10.14744/tjtes.2023.66304
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: The aim of this study is to investigate mechanical properties of minimally invasive plate osteosynthesis (MIPO), supracutaneousplating (SP), and unilateral external fixators (UEF) which can be performed for open tibial fractures.METHODS: An unstable diaphysial tibia fracture was created in 60 fresh sheep tibia specimens by performing an osteotomy at the middle of bones. Specimens were divided into 3 groups. Specimens underwent fracture fixation with a standard MIPO technique, implanting the plate 15 mm from the bone for SP group. Unilateral uniplanar external fixators were achieved for UEF group. First, thirty specimens (10 specimen for each group) were loaded vertically along the tibial axis to 1800 N. Second, other 30 preperated bones were used for cyclical loading to avoid metal fatigue. For dynamic tests, a 350 N force was applied for 10,000 cycles.RESULTS: In compression testing (vertical loading up to 1800 N) of the three fixation instruments; construct stiffness was highest in MIPO group when compared with SP and UEF groups. While the stiffness of the MIPO group was similar to SP group, it was statistically higher than UEF group (P=0.08 and P=0.002, respectively). SP group was significantly stiffer than UEF group (P=0.0021). The mean peak load was highest in SP group and lowest in UEF group. The peak load in SP group was similar to the MIPO group, it was statistically higher than the UEF group (P=0.743 and P=0.002, respectively).CONCLUSION: Based on the biomechanical properties from this in vitro animal model study, SP technique was biomechanically stronger than UEF and has similar biomechanical properties with MIPO in terms of axial loading.
引用
收藏
页码:1091 / 1097
页数:7
相关论文
共 27 条
[1]   Biomechanical testing of the locking compression plate: When does the distance between bone and implant significantly reduce construct stability? [J].
Ahmad, M. ;
Nanda, R. ;
Bajwa, A. S. ;
Candal-Couto, J. ;
Green, S. ;
Hui, A. C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (03) :358-364
[2]   Externalised locking compression plate as an alternative to the unilateral external fixator: a biomechanical comparative study of axial and torsional stiffness [J].
Ang, B. F. H. ;
Chen, J. Y. ;
Yew, A. K. S. ;
Chua, S. K. ;
Chou, S. M. ;
Chia, S. L. ;
Koh, J. S. B. ;
Howe, T. S. .
BONE & JOINT RESEARCH, 2017, 6 (04) :216-223
[3]  
CHAO EYS, 1989, CLIN ORTHOP RELAT R, P24
[4]  
CHAPMAN MW, 1979, CLIN ORTHOP RELAT R, P120
[5]   The dynamic locking screw (DLS) can increase interfragmentary motion on the near cortex of locked plating constructs by reducing the axial stiffness [J].
Doebele, Stefan ;
Horn, Carsten ;
Eichhorn, Stefan ;
Buchholtz, Arne ;
Lenich, Andreas ;
Burgkart, Rainer ;
Nuessler, Andreas K. ;
Lucke, Martin ;
Andermatt, Daniel ;
Koch, Rudolf ;
Stoeckle, Ulrich .
LANGENBECKS ARCHIVES OF SURGERY, 2010, 395 (04) :421-428
[6]   Staged management of high-energy proximal tibia fractures (OTA types 41) - The results of a prospective, standardized protocol [J].
Egol, KA ;
Tejwani, NC ;
Capla, EL ;
Wolinsky, PL ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (07) :448-455
[7]   Locked Plating of Distal Femur Fractures Leads to Inconsistent and Asymmetric Callus Formation [J].
Lujan, Trevor J. ;
Henderson, Chris E. ;
Madey, Steven M. ;
Fitzpatrick, Dan C. ;
Marsh, J. Lawrence ;
Bottlang, Michael .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (03) :156-162
[8]   Locked plating as an external fixator in treating tibial fractures A PRISMA-compliant systematic review [J].
Luo, Peng ;
Xu, Ding ;
Wu, Jia ;
Chen, Yi-Heng .
MEDICINE, 2017, 96 (49)
[9]   Metaphyseal locking plate as an external fixator for open tibial fracture: Clinical outcomes and biomechanical assessment [J].
Ma, Ching-Hou ;
Wu, Chin-Hsien ;
Jiang, Jiun-Ru ;
Tu, Yuan-Kun ;
Lin, Ting-Sheng .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (02) :501-505
[10]   Metaphyseal locking plate as a definitive external fixator for treating open tibial fractures-Clinical outcome and a finite element study [J].
Ma, Ching-Hou ;
Wu, Chin-Hsien ;
Tu, Yuan-Kun ;
Lin, Ting-Sheng .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (08) :1097-1101