Concurrent validity and reliability of a functional electromechanical dynamometer to assess isometric mid-thigh pull performance

被引:8
|
作者
Baena-Raya, Andres [1 ,2 ]
Diez-Fernandez, David M. [1 ,2 ]
Garcia-Ramos, Amador [3 ,4 ]
Soriano-Maldonado, Alberto [1 ,2 ]
Rodriguez-Perez, Manuel A. [1 ,2 ]
机构
[1] Univ Almeria, Fac Educ Sci, Dept Educ, Almeria, Spain
[2] Univ Almeria, CERNEP Res Ctr, SPORT Res Grp CTS 104, Almeria, Spain
[3] Univ Granada, Fac Sport Sci, Dept Phys Educ & Sport, Camino Alfacar 21, Granada 18071, Spain
[4] Univ Catolica Santisima Concepcion, Fac Educ, Dept Sports Sci & Phys Conditioning, Concepcion, Chile
关键词
Functional electromechanical dynamometer; peak force; rate of force development; strength; testing; reproducibility; FORCE-VELOCITY RELATIONSHIP; AGILITY PERFORMANCE; SPORTS-MEDICINE; STRENGTH; DIRECTION; POWER; POSITION; SPRINT; SPEED; SQUAT;
D O I
10.1177/17543371211030180
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The aim of this study was to examine the concurrent validity and reliability of a functional electromechanical dynamometer (FEMD) to assess the isometric mid-thigh pull (IMTP) kinetic variables: peak force (PF), rate of force development (RFD), and time-specific force values (50-, 100-, 150-, and 200-ms). Twenty-seven male collegiate athletes (age: 22.9 +/- 1.9 years; stature: 184.8 +/- 10.4 cm; body mass: 84.2 +/- 11.8 kg) performed four IMTP trials simultaneously on a force platform and the FEMD. The PF variables calculated from performance of the IMTP on both devices were reliable (CV < 3%; ICC > 0.90) and valid (bias < 13.9 N; random error < 52.1 N; r = 1.00), but they showed heteroscedasticity of the errors (R-2 > 0.23). The RFD (CV > 10.88%; ICC < 0.76) and initial force (CV > 8.81%; ICC < 0.76) variables did not reach an acceptable reliability for any device, but they showed strong associations between them (r range = 0.53-0.69). These results indicate that the FEMD is an acceptable alternative to assess athlete's maximal force production (i.e. PF), but the data collected with FEMD and force plates should not be used interchangeably.
引用
收藏
页码:197 / 204
页数:8
相关论文
共 47 条
  • [1] VALIDITY AND RELIABILITY OF A PORTABLE ISOMETRIC MID-THIGH CLEAN PULL
    James, Lachlan P.
    Roberts, Llion A.
    Haff, G. Gregory
    Kelly, Vincent G.
    Beckman, Emma M.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (05) : 1378 - 1386
  • [2] Relationships of isometric mid-thigh pull variables to weightlifting performance
    Beckham, G.
    Mizuguchi, S.
    Carter, C.
    Sato, K.
    Ramsey, M.
    Lamont, H.
    Hornsby, G.
    Haff, G.
    Stone, M.
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2013, 53 (05): : 573 - 581
  • [3] Validity and Reliability of a Load Cell Sensor-Based Device for Assessment of the Isometric Mid-Thigh Pull Test
    Montoro-Bombu, Raynier
    Gomes, Beatriz Branquinho
    Santos, Amandio
    Rama, Luis
    SENSORS, 2023, 23 (13)
  • [4] Effects of mental fatigue on isometric mid-thigh pull performance and muscle activities
    Yang, Hyung Suk
    Atkins, Lee T.
    James, C. Roger
    PLOS ONE, 2025, 20 (03):
  • [5] The Acute Effects of Whole Body Vibration on Isometric Mid-Thigh Pull Performance
    Hornsby, W. Guy
    South, Mark A.
    Stone, Jason D.
    Lamont, Hugh S.
    Haff, G. Gregory
    Stone, Michael H.
    VIBRATION, 2020, 3 (02): : 85 - 98
  • [6] Reliability, Variability and Minimal Detectable Change of the Isometric Mid-Thigh Pull in Adolescent Dancers
    Kolokythas, Nico
    Metsios, George S.
    Galloway, Shaun M.
    Allen, Nick
    Wyon, Matthew A.
    JOURNAL OF DANCE MEDICINE & SCIENCE, 2024, 28 (01): : 14 - 20
  • [7] Validity and intra-session reliability of a low-cost device for assessing isometric mid-thigh pull force
    Couto, Diego
    Cunha, Rafael
    Lage, Victor
    Rocha Jr, Valdinar
    Santos, Wanderson
    Ferreira Jr, Joao B.
    Tufano, James
    Vieira, Amilton
    HUMAN MOVEMENT, 2023, 24 (02) : 52 - 58
  • [8] The association between grip strength and isometric mid-thigh pull performance in elite footballers
    Rhodes, D.
    Jeffery, J.
    Carling, C.
    Alexander, J.
    SCIENCE & SPORTS, 2022, 37 (02)
  • [9] Test-retest reliability of a single isometric mid-thigh pull protocol to assess peak force and strength-endurance
    Grover, Zak
    McCormack, James
    Cooper, Jonathan
    Fisher, James P.
    PEERJ, 2024, 12
  • [10] Scoping Review of the Isometric Mid-Thigh Pull Performance Relationship to Dynamic Sport Performance Assessments
    Giles, Garrett
    Lutton, Greg
    Martin, Joel
    JOURNAL OF FUNCTIONAL MORPHOLOGY AND KINESIOLOGY, 2022, 7 (04)