Intra-individual comparison of image quality of the coronary arteries between photon-counting detector and energy-integrating detector CT systems

被引:16
作者
Pinos, Daniel [1 ]
Griffith III, Joseph [1 ]
Emrich, Tilman [1 ,2 ,3 ]
Schoepf, U. Joseph [1 ,11 ]
O'Doherty, Jim [1 ,4 ]
Zsarnoczay, Emese [1 ,5 ]
Fink, Nicola [1 ,6 ]
Vecsey-Nagy, Milan [1 ,7 ]
Suranyi, Pal [1 ]
Tesche, Christian [1 ,8 ,9 ]
Aquino, Gilberto J. [1 ]
Varga-Szemes, Akos [1 ]
Brandt, Verena [1 ,10 ]
机构
[1] Med Univ South Carolina, Dept Radiol & Radiol Sci, Div Cardiovasc Imaging, 25 Courtenay Dr, Charleston, SC 29425 USA
[2] Univ Med Ctr Mainz, Dept Diagnost & Intervent Radiol, 1 Langenbeckstr, D-55131 Mainz, Germany
[3] German Ctr Cardiovasc Res DZHK, Partner Site Rhine Main, 1 Langenbeckstr, D-55131 Mainz, Germany
[4] Siemens Med Solut USA, 40 Liberty Blvd, Malvern, PA 19355 USA
[5] Semmelweis Univ, Med Imaging Ctr, Korany Sandor Utca 2, H-1083 Budapest, Hungary
[6] Ludwig Maximilians Univ Munchen, Univ Hosp Munich, Dept Radiol, 15 Marchioninistr, D-81377 Munich, Germany
[7] Semmelweis Univ, Med Imaging Ctr, MTA SE Cardiovasc Imaging Res Grp, 18 Hataror ut, H-1122 Budapest, Hungary
[8] Clin Augustinum Munich, Dept Cardiol, 16 Wolkerweg, D-81375 Munich, Germany
[9] Ludwig Maximilians Univ Munchen, Munich Univ Clin, Dept Cardiol, Lazarettstr 36, D-80636 Munich, Germany
[10] Robert Bosch Krankenhaus, Dept Cardiol & Angiol, Auerbachstr 110, D-70376 Stuttgart, Germany
[11] Med Univ South Carolina, Shley River Tower,25 Courtenay Dr, Charleston, SC 29425 USA
关键词
Photon-counting CT; CT angiography; Coronary arteries; Image quality; Computed tomography; Virtual monoenergetic imaging; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; PERFORMANCE; COMMITTEE;
D O I
10.1016/j.ejrad.2023.111008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To intra-individually compare the objective and subjective image quality of coronary computed tomography angiography (CCTA) between photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT).Method: Consecutive patients undergoing clinically indicated CCTA on an EID-CT system were prospectively enrolled for a research CCTA performed on a PCD-CT system within 30 days. Polychromatic images were reconstructed for both EIDand PCD-CT, while virtual monoenergetic images (VMI) were generated at 40, 45, 50, 55, 60 and 70 keV for PCD-CT. Two blinded readers calculated contrast-to-noise ratio (CNR) for each major coronary artery and rated image noise, vessel attenuation, vessel sharpness, and overall quality on a 1-5 Likert scale. Patients were then stratified by body mass index (BMI) [high (>30 kg/m2) vs low (<30 kg/m2)] for subgroup analysis.Results: A total of 20 patients (67.5 & PLUSMN; 9.0 years, 75% male) were included in the study. Compared with EID-CT, coronary artery CNR values from PCD-CT monoenergetic and polychromatic reconstructions were all significantly higher than CNR values from EID-CT, with incrementally greater differences in obese subjects (all p < 0.008). Subjective image noise and sharpness were also significantly higher for all VMI reconstructions compared to EID-CT (all p < 0.008). All subjective scores were significantly higher for 55, 60, and 70 keV PCD-CT than EIDCT values (all p < 0.05).Conclusions: The improved objective and subjective image quality of PCD-CT compared to EID-CT may provide better visualization of the coronary arteries for a wide array of patients, especially those with a high BMI.
引用
收藏
页数:7
相关论文
共 28 条
[1]   SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: A report of the society of Cardiovascular Computed Tomography Guidelines Committee Endorsed by the North American Society for Cardiovascular Imaging (NASCI) [J].
Abbara, Suhny ;
Blanke, Philipp ;
Maroules, Christopher D. ;
Cheezum, Michael ;
Choi, Andrew D. ;
Han, B. Kelly ;
Marwan, Mohamed ;
Naoum, Chris ;
Norgaard, Bjarne L. ;
Rubinshtein, Ronen ;
Schoenhagen, Paul ;
Villines, Todd ;
Leipsic, Jonathon .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (06) :435-449
[2]   Coronary Computed Tomography Angiography From Clinical Uses to Emerging Technologies JACC State-of-the-Art Review [J].
Abdelrahman, Khaled M. ;
Chen, Marcus Y. ;
Dey, Amit K. ;
Virmani, Renu ;
Finn, Aloke V. ;
Khamis, Ramzi Y. ;
Choi, Andrew D. ;
Min, James K. ;
Williams, Michelle C. ;
Buckler, Andrew J. ;
Taylor, Charles A. ;
Rogers, Campbell ;
Samady, Habib ;
Antoniades, Charalambos ;
Shaw, Leslee J. ;
Budoff, Matthew J. ;
Hoffmann, Udo ;
Blankstein, Ron ;
Narula, Jagat ;
Mehta, Nehal N. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (10) :1226-1243
[3]   Selective laser trabeculoplasty vs micropulse laser trabeculoplasty in open-angle glaucoma [J].
Abramowitz, Benjamin ;
Chadha, Nisha ;
Kouchouk, Amr ;
Alhabshan, Rashed ;
Belyea, David A. ;
Lamba, Tania .
CLINICAL OPHTHALMOLOGY, 2018, 12 :1599-1604
[4]   Improved coronary artery contrast enhancement using noise-optimised virtual monoenergetic imaging from dual-source dual-energy computed tomography [J].
Arendt, Christophe T. ;
Czwikla, Rouben ;
Lenga, Lukas ;
Wichmann, Julian L. ;
Albrecht, Moritz H. ;
Booz, Christian ;
Martin, Simon S. ;
Leithner, Doris ;
Tischendorf, Patricia ;
Blandino, Alfredo ;
Vogl, Thomas J. ;
D'Angelo, Tommaso .
EUROPEAN JOURNAL OF RADIOLOGY, 2020, 122
[5]   Impact of CT Photon-Counting Virtual Monoenergetic Imaging on Visualization of Abdominal Arterial Vessels [J].
Dillinger, Daniel ;
Overhoff, Daniel ;
Booz, Christian ;
Kaatsch, Hanns L. ;
Piechotka, Joel ;
Hagen, Achim ;
Froelich, Matthias F. ;
Vogl, Thomas J. ;
Waldeck, Stephan .
DIAGNOSTICS, 2023, 13 (05)
[6]  
Euler A, 2022, INVEST RADIOL, V57, P115, DOI 10.1097
[7]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[8]   The Identification of Calcified Coronary Plaque Is Associated With Initiation and Continuation of Pharmacological and Lifestyle Preventive Therapies A Systematic Review and Meta-Analysis [J].
Gupta, Ankur ;
Lau, Emily ;
Varshney, Ravi ;
Hulten, Edward A. ;
Cheezum, Michael ;
Bittencourt, Marcio S. ;
Blaha, Michael J. ;
Wong, Nathan D. ;
Blumenthal, Roger S. ;
Budoff, Matthew J. ;
Umscheid, Craig A. ;
Nasir, Khurram ;
Blankstein, Ron .
JACC-CARDIOVASCULAR IMAGING, 2017, 10 (08) :833-842
[9]   Contrast-Enhanced Abdominal CT with Clinical Photon-Counting Detector CT: Assessment of Image Quality and Comparison with Energy-Integrating Detector CT [J].
Higashigaito, Kai ;
Euler, Andre ;
Eberhard, Matthias ;
Flohr, Thomas G. ;
Schmidt, Bernhard ;
Alkadhi, Hatem .
ACADEMIC RADIOLOGY, 2022, 29 (05) :689-697
[10]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183