Technical note: Evaluation of the acoustic radiation force imaging for predicting HIFU focus with in vitro and ex vivo experiments

被引:3
作者
Feng, Lian [1 ]
Shi, Xinwang [1 ]
Zhou, Fang [1 ]
Chen, Yanhua [1 ]
Zhou, Xiaowei [1 ,2 ]
机构
[1] Chongqing Med Univ, Coll Biomed Engn, State Key Lab Ultrasound Engn Med, Chongqing, Peoples R China
[2] Chongqing Med Univ, Coll Biomed Engn, State Key Lab Ultrasound Engn Med, Chongqing 400016, Peoples R China
关键词
acoustic radiation force imaging; high-intensity focused ultrasound; motion estimation; surgery planning; ULTRASOUND; DISPLACEMENTS; CARCINOMA; THERAPY; LIVER;
D O I
10.1002/mp.16565
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundHigh-intensity focused ultrasound (HIFU) is currently used for the treatment of various diseases, but it still lacks a reliable technique in the preoperative stage to accurately place its "energy blade" onto diseased targets. Acoustic radiation force imaging (ARFI) was recently introduced to tackle this issue, but its applicability and limitations were not clear. PurposeThe aim of this study was to evaluate the performance of ARFI method in prediction of HIFU focal location at the preoperative stage. MethodsA point spread function (PSF) localization method, which was borrowed from the ultrasound super resolution field, was used to validate the core autocorrelation-based motion estimation algorithm in the ARFI procedure. Accuracy of the ARFI method for estimating the HIFU focus were tested with in vitro and ex vivo experiments with a clinically equivalent HIFU system. Comparisons were made between the estimated focal locations and those of the damaged area after the testing objects were cut open. ResultsResults showed that the PSF localization was able to serve as a validating method for motion detection only when the tissue displacement was large. With the ARFI method, location of the HIFU focus could be accurately predicted by a 2D motion map preoperatively, and the axial spatial errors were less than 0.5 mm. However, the derived 2D motion maps can only be valuable when the acoustic stimulation in ARFI were strong enough, which was probably due to the fact that the HIFU focal locations were at large depths and the ultrasound imaging signal had low signal to noise ratio. ConclusionThe ARFI method was indeed an accurate technique for preoperatively predicting HIFU focus in vitro and ex vivo. If clinical applications were to be considered, particularly in deep tissues, efforts might need to be made to improve ability of the ultrasound motion estimation technique.
引用
收藏
页码:5449 / 5459
页数:11
相关论文
共 35 条
  • [1] [Anonymous], 2006, EAUEBU Update Series, DOI DOI 10.1016/J.EEUS.2006.01.002
  • [2] Thermal Therapy With a Fully Electronically Steerable HIFU Phased Array Using Ultrasound Guidance and Local Harmonic Motion Monitoring
    Aslani, Pegah
    Drost, Leah
    Huang, Yuexi
    Lucht, Benjamin B. C.
    Wong, Erin
    Czarnota, Gregory
    Yee, Caitlin
    Wan, Bo Angela
    Ganesh, Vithusha
    Gunaseelan, Samuel T.
    David, Elizabeth
    Chow, Edward
    Hynynen, Kullervo
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (07) : 1854 - 1862
  • [3] In Vivo Ultrasound Thermography in Presence of Temperature Heterogeneity and Natural Motions
    Bayat, Mahdi
    Ballard, John Robert
    Ebbini, Emad S.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (02) : 450 - 457
  • [4] Combined Ultrasonic Thermal Ablation with Interleaved ARFI Image Monitoring Using a Single Diagnostic Curvilinear Array: A Feasibility Study
    Bing, Kristin Frinkley
    Rouze, Ned C.
    Palmeri, Mark L.
    Rotemberg, Veronica M.
    Nightingale, Kathryn R.
    [J]. ULTRASONIC IMAGING, 2011, 33 (04) : 217 - 232
  • [5] Cafarelli A, 2018, IEEE ENG MED BIO, P5713, DOI 10.1109/EMBC.2018.8513591
  • [6] The status of high-intensity focused ultrasound in the treatment of localized prostate cancer and the impact of a combined resection
    Christian Chaussy
    Stefan Thüroff
    [J]. Current Urology Reports, 2003, 4 (3) : 248 - 252
  • [7] Harmonic Motion Imaging in Abdominal Tumor Detection and HIFU Ablation Monitoring: A Feasibility Study in a Transgenic Mouse Model of Pancreatic Cancer
    Chen, Hong
    Han, Yang
    Payen, Thomas
    Palermo, Carmine
    Oliver, Kenneth
    Konofagou, Elisa
    [J]. 2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 923 - 926
  • [8] In Vivo Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using Microbubbles
    Christensen-Jeffries, Kirsten
    Browning, Richard J.
    Tang, Meng-Xing
    Dunsby, Christopher
    Eckersley, Robert J.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) : 433 - 440
  • [9] Acoustic radiation force impulse imaging of thermally- and chemically-induced lesions in soft tissues: Preliminary ex vivo results
    Fahey, BJ
    Nightingale, KR
    Stutz, DL
    Trahey, GE
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (03) : 321 - 328
  • [10] MRI-guided Focused Ultrasound Ablation for Localized Intermediate-Risk Prostate Cancer: Early Results of a Phase II Trial
    Ghai, Sangeet
    Finelli, Antonio
    Corr, Kateri
    Chan, Rosanna
    Jokhu, Sarah
    Li, Xuan
    McCluskey, Stuart
    Konukhova, Anna
    Hlasny, Eugen
    van der Kwast, Theodorus H.
    Incze, Peter F.
    Zlotta, Alexandre R.
    Hamilton, Robert J.
    Haider, Masoom A.
    Kucharczyk, Walter
    Perlis, Nathan
    [J]. RADIOLOGY, 2021, 298 (03) : 695 - 703