Ophthalmic artery stenosis on three-dimensional rotational angiography: Interrater agreement, prevalence, and risk factors

被引:0
|
作者
Diprose, William K. [1 ,2 ,4 ,6 ]
Wang, Michael T. M. [3 ,4 ]
Reidy, Joseph [1 ]
Ma, Alice [1 ,2 ]
Brodie, James [3 ,5 ]
Steinfort, Brendan [1 ,2 ]
机构
[1] Royal North Shore Hosp, Dept Neurosurg, St Leonards, NSW, Australia
[2] Westmead Hosp, Dept Neurosurg, Westmead, NSW, Australia
[3] Univ Auckland, New Zealand Natl Eye Ctr, Dept Ophthalmol, Auckland, New Zealand
[4] Univ Auckland, Fac Med & Hlth Sci, Dept Med, Auckland, New Zealand
[5] Norfolk & Norwich Univ Hosp NHS Fdn Trust, Dept Ophthalmol, Norwich, England
[6] Univ Auckland, Fac Med & Hlth Sci, Dept Med, Private Bag 92019, Auckland 1142, New Zealand
关键词
Ophthalmic artery; age-related macular degeneration; three-dimensional rotational angiography; AMAUROSIS FUGAX; ATHEROSCLEROSIS; SIMULATION; SMOKING;
D O I
10.1177/15910199241233020
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background There is emerging interest in ophthalmic artery (OA) stenosis angioplasty for the treatment of age-related macular degeneration. Three-dimensional rotational angiography (3DRA) could be used during conventional angiography to determine the presence and severity of OA stenosis. In patients who had undergone 3DRA of the internal carotid artery, we aimed to assess the interrater agreement, prevalence, and risk factors for OA stenosis.Methods Consecutive patients from two centers who had undergone conventional angiography with 3DRA of the internal carotid arteries were enrolled in this study. 3DRAs were independently double read for the presence of OA stenosis, as defined as narrowing of the proximal OA of at least 50% when compared to the more distal "normal" OA. Interrater agreement for the evaluation of OA stenosis was assessed with the Cohen's kappa coefficient. Univariate and multivariable logistic regression were used to identify potential predictors of OA stenosis.Results Three hundred and two patients (97 men; mean +/- SD 57.6 +/- 13.4 years) were included in the analysis. Cohen's kappa coefficient (95% CI) was 0.877 (0.798-0.956). OA stenosis was present in 45 patients (14.9%). Multiple logistic regression demonstrated that female sex (odds ratio [OR] = 2.70, 95% confidence interval [CI] 1.18-6.09, p = 0.02) and smoking (OR = 2.11, 95% CI 1.10-4.06, p = 0.03) were significant risk factors for OA stenosis. Age, hypertension, diabetes, coronary artery disease, and subarachnoid hemorrhage were not associated with OA stenosis.Conclusion The evaluation of OA stenosis on 3DRA had excellent interrater agreement. OA stenosis was common and was associated with smoking and female sex.
引用
收藏
页数:5
相关论文
共 34 条
  • [1] Ruptured aneurysm of the ophthalmic artery trunk demonstrated by three-dimensional rotational angiography: Case report
    Yanaka, K
    Matsumaru, Y
    Kamezaki, T
    Nose, T
    NEUROSURGERY, 2002, 51 (04) : 1066 - 1069
  • [2] Three-dimensional rotational angiography guidance for aneurysm surgery
    Raabe, Andreas
    Beck, Juergen
    Rohde, Stefan
    Berkefeld, Joachim
    Seifert, Volker
    JOURNAL OF NEUROSURGERY, 2006, 105 (03) : 406 - 411
  • [3] Feasibility of a three-dimensional rotational angiography road map for individualized guidance of uterine artery catheterization
    Li, W. Q.
    Deng, X. S.
    Li, G. B.
    Kang, Y. G.
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2020, 47 (05) : 687 - 692
  • [4] Cutting balloon angioplasty for carotid artery in-stent stenosis supported by three-dimensional rotational angiography with automated vessel analysis software - Technical note
    Akiyama, Yasuhiko
    Moritake, Kouzo
    Miyazaki, Takeshi
    Kowari, Kentaro
    Sato, Hidetoshi
    Shimada, Toshio
    NEUROLOGIA MEDICO-CHIRURGICA, 2008, 48 (05) : 235 - 238
  • [5] Percutaneous pulmonary valve implantation guided by three-dimensional rotational angiography
    Krings, Gregor J.
    Driesen, Bart W.
    Warmerdam, Evangeline G.
    Molenschot, Mirella C.
    Sieswerda, Gert-Jan T.
    Doevendans, Pieter A.
    van Dijk, Arie P. J.
    Voskuil, M.
    INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE, 2024, 18
  • [6] Diagnostic Utility of Three-Dimensional Rotational Angiography in Congenital Cardiac Catheterization
    Aldoss, Osamah
    Fonseca, Brian M.
    Truong, Uyen T.
    Bracken, John
    Darst, Jeffrey R.
    Guo, Ruixin
    Jones, Tamekia L.
    Fagan, Thomas E.
    PEDIATRIC CARDIOLOGY, 2016, 37 (07) : 1211 - 1221
  • [7] Diagnostic Utility of Three-Dimensional Rotational Angiography in Congenital Cardiac Catheterization
    Osamah Aldoss
    Brian M. Fonseca
    Uyen T. Truong
    John Bracken
    Jeffrey R. Darst
    Ruixin Guo
    Tamekia L. Jones
    Thomas E. Fagan
    Pediatric Cardiology, 2016, 37 : 1211 - 1221
  • [8] The Three-Dimensional Computed Tomography Anatomic Features of Internal Carotid Artery-Ophthalmic Artery
    Xu, Bingqiang
    Liu, Huitong
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (05) : 1609 - 1611
  • [9] Intra-arterial haemodynamic changes during cerebral three-dimensional rotational angiography
    Peter Waldenberger
    Andreas Chemelli
    Ammar Mallouhi
    European Radiology, 2009, 19 : 503 - 508
  • [10] Three-dimensional rotational angiography utility in imaging and intervention in a case of pulmonary arteriovenous malformation
    Awasthy, Neeraj
    Gupta, Amol
    ANNALS OF PEDIATRIC CARDIOLOGY, 2021, 14 (04) : 533 - 535