Accelerated charging of PCM in coil heat exchangers via central return tube and inlet positioning: A 3D analysis

被引:6
作者
Ben Khedher, Nidhal [1 ,2 ]
Hosseinzadeh, Khashayar [3 ]
Abed, Azher M. [4 ]
Khosravi, Koorosh [5 ]
Mahdi, Jasim M. [6 ]
Sultan, Hakim S. [7 ]
Mohammed, Hayder I. [8 ]
Talebizadehsardari, Pouyan [9 ]
机构
[1] Univ Hail, Coll Engn, Dept Mech Engn, Hail, Saudi Arabia
[2] Univ Monastir, Lab Thermal & Energet Syst Studies LESTE, Natl Sch Engn Monastir, Monastir, Tunisia
[3] Babol Noshirvani Univ Technol, Dept Mech Engn, Babol, Iran
[4] Al Mustaqbal Univ, Air Conditioning & Refrigerat Tech Engn Dept, Babylon 51001, Iraq
[5] Rensselaer Polytech Inst, Dept Mech Aerosp & Nucl Engn, 110 8 th St, Troy, NY 12180 USA
[6] Univ Baghdad, Dept Energy Engn, Baghdad 10071, Iraq
[7] Univ Warith Al Anbiyaa, Coll Engn, Karbalaa 56001, Iraq
[8] Imam Jaafar Al Sadiq Univ, Dept Cooling & Air Conditioning Engn, Baghdad, Iraq
[9] Univ Nottingham, Power Elect Machines & Control PEMC Res Grp, Nottingham, England
关键词
Phase change materials; Coiled tube; Numerical simulation; Melting; Central return tube; THERMAL-ENERGY STORAGE; PHASE-CHANGE MATERIAL; TRIPLEX-TUBE; TRANSFER ENHANCEMENT; METAL FOAM; SYSTEM; PERFORMANCE; FINS; NANOPARTICLES; UNIT;
D O I
10.1016/j.icheatmasstransfer.2024.107275
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a 3D numerical analysis of the melting behaviour of a phase changing material (PCM) in a helix-shaped coil-tube heat exchanger, a critical component in latent heat storage (LHS) systems. The analysis explores the impact of the heat transfer fluid's flow route on the system's performance. Specifically, three unique designs of coiled-tube heat exchangers were assessed: a conventional central return tube with an inlet at the bottom, a central return tube with an inlet at the top, and a conventional coiled-tube. The key performance measures under investigation were the melting time of the PCM, average temperature, and average charge rate. Results revealed the central return tube configurations enhance initial melting rates and charging capacity compared to the conventional coil, with the top inlet design outperforming the bottom inlet by 16.5% in melting rate after 5000 s from the melting initiation. Meanwhile, the configuration with the central return tube at the top demonstrated incremental energy storage increases of 18.8%, 13.1% and 1.9% at operating time intervals of 1000, 5000 and 10,000, respectively, compared to the conventional system. These results underline the benefits of a central return tube with optimized inlet positioning in improving the melting effectiveness in LHS systems.
引用
收藏
页数:11
相关论文
共 51 条
  • [1] Numerical study of PCM solidification in a triplex tube heat exchanger with internal and external fins
    Al-Abidi, Abduljalil A.
    Mat, Sohif
    Sopian, K.
    Sulaiman, M. Y.
    Mohammad, Abdulrahman Th
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 61 : 684 - 695
  • [2] Internal and external fin heat transfer enhancement technique for latent heat thermal energy storage in triplex tube heat exchangers
    Al-Abidi, Abduljalil A.
    Mat, Sohif
    Sopian, K.
    Sulaiman, M. Y.
    Mohammad, Abdulrahman Th.
    [J]. APPLIED THERMAL ENGINEERING, 2013, 53 (01) : 147 - 156
  • [3] How Much Building Renewable Energy Is Enough? The Vertical City Weather Generator (VCWG v1.4.4)
    Aliabadi, Amir A.
    Moradi, Mohsen
    McLeod, Rachel M.
    Calder, David
    Dernovsek, Robert
    [J]. ATMOSPHERE, 2021, 12 (07)
  • [4] Numerical and experimental study of melting in a spherical shell
    Assis, E.
    Katsman, L.
    Ziskind, G.
    Letan, R.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (9-10) : 1790 - 1804
  • [5] The potential of arc-shaped fins for expedited solidification in triplex-tube latent heat storage: Parametric investigation
    Boujelbene, Mohamed
    Mahdi, Jasim M.
    Sultan, Hakim S.
    Homod, Raad Z.
    Yvaz, A.
    Chatroudi, Ilia Shojaeinasab
    Talebizadehsardari, Pouyan
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 82
  • [6] Numerical and experimental investigation on latent thermal energy storage system with spiral coil tube and paraffin/expanded graphite composite PCM
    Chen, Caixing
    Zhang, Hua
    Gao, Xuenong
    Xu, Tao
    Fang, Yutang
    Zhang, Zhengguo
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 126 : 889 - 897
  • [7] Coyle ED, 2014, Understanding the Global Energy Crisis
  • [8] Evaluation and optimization of thermal performance for a finned double tube latent heat thermal energy storage
    Deng, Shengxiang
    Nie, Changda
    Jiang, Haojie
    Ye, Wei-Biao
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 130 : 532 - 544
  • [9] Acceleration of melting process of phase change material using an innovative triplex-tube helical-coil storage unit: Three-dimensional numerical study
    Entezari, Soroush
    Taheri, Amin
    Khatibi, Meysam
    Niazmand, Hamid
    [J]. JOURNAL OF ENERGY STORAGE, 2021, 39
  • [10] Phase change in multi-tube heat exchangers
    Esapour, M.
    Hosseini, M. J.
    Ranjbar, A. A.
    Pahamli, Y.
    Bahrampoury, R.
    [J]. RENEWABLE ENERGY, 2016, 85 : 1017 - 1025