Relapse and failure rates between CAD/CAM and conventional fixed retainers: a 2-year follow-up of a randomized controlled clinical trial

被引:4
|
作者
Tran, Giau [1 ]
Rucker, Ryan [1 ]
Foley, Patrick [1 ]
Bankhead, Brent [1 ]
Adel, Samar M. [1 ,2 ]
Kim, Ki Beom [1 ]
机构
[1] St Louis Univ, Dept Orthodont, 3320 Rutger St, St Louis, MO 63104 USA
[2] Alexandria Univ, Fac Dent, Dept Orthodont, Alexandria 21526, Egypt
关键词
CAD/CAM; digital orthodontics; fixed retainers; relapse; ORTHODONTIC RETAINERS; SINGLE-CENTER; RETENTION; PERIOD; STABILITY;
D O I
10.1093/ejo/cjad079
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Retention has been always considered a major challenge in orthodontics. Recently computer-aided design/computer-aided manufacturing (CAD/CAM) fixed retainers (FRs) have been introduced as a marked development in retainer technology, offering potential advantages.Objective: The objective of this study was to compare the differences in relapse and failure rates in patients treated with FRs using CAD/CAM technology, lab-based technique, and chairside method.Trial design: A double-blinded, prospective, randomized controlled clinical trial was conducted over a 2-year period at a single centre.Methods: Participants: Initially, 81 patients were recruited, but only 43 patients who came back for a 2-year retention were included in the study.Interventions: These patients were divided into three groups: CAD/CAM group with multistranded Stainless Steel wires (CAD/CAM, n = 14), lab group with the same multistranded wires (lab, n = 15), and a chairside group with Stainless Steel Ortho-FlexTech wires (chairside, n = 14).Outcomes: Inter-canine width (ICW) and Little's irregularity index were digitally measured from scans at the orthodontic debonding (T1), 6-month retention (T2), 1-year retention (T3), and 2-year retention (T4) visits. All forms of failure were documented and analyzed.Randomization: Participants were randomly assigned to the three groups using online randomization software (randomization.com) by a statistician who was not involved in the study.Blinding: Patients were blinded in terms of the FR group to which they were each randomly assigned. The principal investigator was blinded upon data analysis since patients' records were coded to minimize observer and measurement bias.Results: Initially 81 patients were assessed for eligibility. Seventy-five patients were randomly allocated into the three study groups. After 2-year follow-up, 43 patients came back for the follow-up and were analyzed. The CAD/CAM group showed significantly less reduction in ICW compared to the chairside group at all time intervals (P < .05) and compared to the lab group at 6 months (P = .038). In terms of LII, the CAD/CAM group exhibited significantly less change than the chairside and lab groups at all time intervals (P < .05). The CAD/CAM group had the lowest failure rate (21.4%), followed by chairside group (28.6%) and then lab group (33.3%), however the differences were insignificant. No harms were observed in the current study.Conclusion: Within 2 years of fixed retention, CAD/CAM FRs showed significantly less relapse than lab-based and chairside FRs. However, there was no significant difference in failure rates among the groups.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Stability, survival, patient satisfaction, and cost-minimization of CAD/CAM versus conventional multistranded fixed retainers in orthodontic patients: a 2-year follow-up of a two-centre randomized controlled trial
    Pullisaar, Helen
    Cattaneo, Paolo M.
    Gera, Arwa
    Sankiewicz, Monika
    Bilinska, Malgorzata
    Vandevska-Radunovic, Vaska
    Cornelis, Marie A.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2024, 46 (02)
  • [2] Stability, survival, and patient satisfaction with CAD/CAM versus conventional multistranded fixed retainers in orthodontic patients: a 6-month follow-up of a two-centre randomized controlled clinical trial
    Gera, Arwa
    Pullisaar, Helen
    Cattaneo, Paolo M.
    Gera, Shadi
    Vandevska-Radunovic, Vaska
    Cornelis, Marie A.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2023, 45 (01) : 58 - 67
  • [3] Comparative assessment of relapse and failure between CAD/CAM stainless steel and standard stainless steel fixed retainers in orthodontic retention patients: A randomized controlled trial
    Shim, Hun
    Foley, Patrick
    Bankhead, Brent
    Kim, Ki Beom
    ANGLE ORTHODONTIST, 2022, 92 (01) : 87 - 94
  • [4] Treating Prolonged Grief Disorder: A 2-Year Follow-Up of a Randomized Controlled Trial
    Bryant, Richard A.
    Kenny, Lucy
    Joscelyne, Amy
    Rawson, Natasha
    Maccallum, Fiona
    Cahill, Catherine
    Hopwood, Sally
    Nickerson, Angela
    JOURNAL OF CLINICAL PSYCHIATRY, 2017, 78 (09) : 1363 - 1368
  • [5] Stability of anterior crossbite correction: A randomized controlled trial with a 2-year follow-up
    Wiedel, Anna-Paulina
    Bondemark, Lars
    ANGLE ORTHODONTIST, 2015, 85 (02) : 189 - 195
  • [6] Comparing the effects of CAD/CAM nickel-titanium lingual retainers on teeth stability and periodontal health with conventional fixed and removable retainers: A randomized clinical trial
    Alrawas, Mohamad Basel
    Kashoura, Yaman
    Tosun, Ozgur
    Oz, Ulas
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2021, 24 (02) : 241 - 250
  • [7] Effects of fixed vs removable orthodontic retainers on stability and periodontal health: 4-year follow-up of a randomized controlled trial
    Al-Moghrabi, Dalya
    Johal, Ama
    O'Rourke, Niamh
    Donos, Nikolaos
    Pandis, Nikolaos
    Gonzales-Marin, Cecilia
    Fleming, Padhraig S.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2018, 154 (02) : 167 - +
  • [8] Prediction of Response to Treatment in a Randomized Clinical Trial of Couple Therapy: A 2-Year Follow-Up
    Baucom, Brian R.
    Atkins, David C.
    Simpson, Lorelei E.
    Christensen, Andrew
    JOURNAL OF CONSULTING AND CLINICAL PSYCHOLOGY, 2009, 77 (01) : 160 - 173
  • [9] Cardiovascular event rates in the MOSAIC trial: 2-year follow-up data
    Turnbull, C. D.
    Craig, S. E.
    Kohler, M.
    Nicoll, D.
    Stradling, J.
    THORAX, 2014, 69 (10) : 950 - 950
  • [10] Encode Protocol Versus Conventional Protocol for Single-Implant Restoration: A Prospective 2-Year Follow-Up Randomized Controlled Trial
    Abduo, Jaafar
    Lee, Choy Lin
    Sarfarazi, Golnaz
    Xue, Bradley
    Judge, Roy
    Darby, Ivan
    JOURNAL OF ORAL IMPLANTOLOGY, 2021, 47 (01) : 36 - 43