A Comprehensive Method for Online Switch Fault Diagnosis and Capacitor Condition Monitoring of Three-Level T-Type Inverters

被引:10
作者
Zhang, Weiwei [1 ]
He, Yigang [1 ]
Wang, Xiao [1 ]
Chen, Jianfei [1 ]
机构
[1] Wuhan Univ, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
Condition monitoring (CM); fault diagnosis (FD); open-circuit (OC) fault; parameter estimate; three-level T-type (3L-T) inverter; OPEN-CIRCUIT FAULT; DC-LINK CAPACITORS; VOLTAGE-SOURCE CONVERTERS; RELIABILITY; DESIGN;
D O I
10.1109/TPEL.2023.3262758
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Capacitors and semiconductor power devices are the most fragile components in power electronic systems. Hence, designing a comprehensive method for online switch fault diagnosis (FD) and capacitor condition monitoring (CM) is conducive to guaranteeing the reliability of the three-level T-type (3L-T) inverter in an all-around way. First, based on modeling the 3L-T inverter on the dc link and ac side, the inherent harmonic components of the dc link under normal and open-circuit fault conditions are analyzed. Furthermore, the capacitor current reconstruction method is designed. Subsequently, a comprehensive FD and CM framework is proposed, which consists of signal injection, extra hardware, 3L-T model, FD, and CM submodules. In FD, the detection variable, which is the function of output current and its changing rate, is designed, and the fault location is carried out based on the phase current residual and the sum of the neutral-point voltage residual. The capacitance estimation method is introduced based on the input current reconstruction technology and recursive least squares algorithm using the inherent or injected ac component on the dc link. Finally, experimental results demonstrate that the proposed comprehensive method merits high estimation accuracy, fast dynamic response, and better FD performance under various conditions.
引用
收藏
页码:10183 / 10195
页数:13
相关论文
共 47 条
[1]   Method to diagnose open-circuit faults in active power switches and clamp-diodes of three-level neutral-point clamped inverters [J].
Abadi, Mohsen Bandar ;
Santos Mendes, Andre Manuel ;
Angelo Cruz, Sergio Manuel .
IET ELECTRIC POWER APPLICATIONS, 2016, 10 (07) :623-632
[2]  
Abadi MB, 2012, 2012 XXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), P1893, DOI 10.1109/ICElMach.2012.6350140
[3]   Quasi-Online Technique for Health Monitoring of Capacitor in Single-Phase Solar Inverter [J].
Agarwal, Nikunj ;
Ahmad, Md Waseem ;
Anand, Sandeep .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (06) :5283-5291
[4]   Current Residual Vector-Based Open-Switch Fault Diagnosis of Inverters in PMSM Drive Systems [J].
An, Qun-Tao ;
Sun, Li ;
Sun, Li-Zhi .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (05) :2814-2827
[5]   Fault Detection for IGBT Using Adaptive Thresholds During the Turn-on Transient [J].
Antonio Rodriguez-Blanco, Marco ;
Vazquez-Perez, Amsi ;
Hernandez-Gonzalez, Leobardo ;
Golikov, Victor ;
Aguayo-Alquicira, Jesus ;
May-Alarcon, Manuel .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (03) :1975-1983
[6]   Passive and Online DC Bus Status Monitoring for Back-to-Back Converters Applied to Doubly Fed Induction Machines [J].
Blanco, Cristian ;
Suarez, Andres ;
Gomez-Aleixandre, Carlos ;
Pelaez, Irene ;
Garcia, Pablo .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (04) :4697-4707
[7]   Condition Monitoring of Metallized Polypropylene Film Capacitors in Railway Power Trains [J].
Buiatti, Gustavo Malagoni ;
Martin-Ramos, Juan A. ;
Amaral, Acacio M. R. ;
Dworakowski, Piotr ;
Marques Cardoso, Antonio J. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (10) :3796-3805
[8]   Voltage Difference Residual-Based Open-Circuit Fault Diagnosis Approach for Three-Level Converters in Electric Traction Systems [J].
Chao, Yang ;
Gui, Weihua ;
Chen, Zhiwen ;
Zhang, Jingrong ;
Peng, Tao ;
Yang, Chunhua ;
Karimi, Hamid Reza ;
Ding, Steven X. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (03) :3012-3028
[9]   Open-Circuit Fault Diagnosis Method in NPC Rectifiers Using Fault-Assumed Strategy [J].
Chen, Mingyun ;
He, Yigang .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (11) :13668-13683
[10]   A Novel Diagnostic Technique for Open-Circuited Faults of Inverters Based on Output Line-to-Line Voltage Model [J].
Cheng Shu ;
Chen Ya-Ting ;
Yu Tian-Jian ;
Wu Xun .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (07) :4412-4421