Retrofitting of post-heated RC columns using steel fiber reinforced self-compacting concrete jackets

被引:7
作者
Elsayed, Mahmoud [1 ]
Abou Elmaaty, Mohamed [1 ]
Mohamed, Reem [1 ]
机构
[1] Fayoum Univ, Fac Engn, Civil Engn Dept, Faiyum, Egypt
关键词
Retrofitting; Columns; Elevated temperatures; Steel fiber reinforced self-compacting concrete; BEAMS; POLYMER; STRENGTH; PERFORMANCE; FERROCEMENT; STIFFNESS; DUCTILITY; BEHAVIOR;
D O I
10.1016/j.conbuildmat.2023.132637
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This work aims to examine the effectiveness of using steel fiber-reinforced self-compacting concrete (SFRSCC) jackets in retrofitting RC columns subjected to high temperatures. In order to do that, eleven RC columns were cast and tested under axial loading. One column served as an unheated control column, and ten columns were heated to 400 degrees C and 600 degrees C for two hours. Subsequently, eight columns were retrofitted using SFRSCC jackets. The volume fraction of steel fibers and the thickness of the SFRSCC jackets were the main parameters considered for the retrofitting technique. According to the experimental findings, SFRSCC jackets can significantly enhance the structural performance of post-heated columns as evaluated by failure load, stiffness, and toughness. The percentage increase in the failure load, stiffness, and toughness of retrofitted post-heated columns is greatly impacted by the thickness of the SFRSCC jackets. The retrofitted columns with 25 mm and 50 mm SFRSCC jackets increased their failure load by 63.9% and 211.8%, respectively, relative to that of the heated control column at 600 degrees C. It is obvious that the failure load of the retrofitted columns was not significantly impacted by increasing the volume fraction of steel fiber in the SFRSCC jackets. Finally, a proposed design equation was suggested to predict the failure load of retrofitted post-heated columns with SFRSCC jackets.
引用
收藏
页数:10
相关论文
共 41 条
[1]   Experimental investigation of fire effects on ductility and stiffness of reinforced reactive powder concrete columns under axial compression [J].
Abdulraheem, Mustafa S. ;
Kadhum, Mohammed M. .
JOURNAL OF BUILDING ENGINEERING, 2018, 20 :750-761
[2]   Repairing post-heated L-shaped RC columns with advanced thin concrete jacketing [J].
Abo-Zaid, Laila ;
Hassan, Ahmed ;
Abdel-Hafez, L. M. .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 221 :573-585
[3]   Flexural behavior of RC beams strengthened with steel wire mesh and self-compacting concrete jacketing - experimental investigation and test results [J].
Abu Maraq, Mohamed A. ;
Tayeh, Bassam A. ;
Ziara, Mohamed M. ;
Alyousef, Rayed .
JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2021, 10 :1002-1019
[4]   Fiber reinforced polymer composites in bridge industry [J].
Ali, Hafiz Tauqeer ;
Akrami, Roya ;
Fotouhi, Sakineh ;
Bodaghi, Mahdi ;
Saeedifar, Milad ;
Yusuf, Mohammad ;
Fotouhi, Mohamad .
STRUCTURES, 2021, 30 :774-785
[5]  
American Concrete Institute (ACI), 2002, ACI 211.1-91
[6]  
[Anonymous], 2002, Specification and Guidelines for Self-Compacting Concrete, P32
[7]  
[Anonymous], 2019, 318 ACI, DOI DOI 10.14359/51716937
[8]  
[Anonymous], 2012, INT SCHOLAR RES NOTI
[9]  
[Anonymous], 2020, STANDARD SPECIFICATI
[10]  
ASTM, 2018, C39C39M18 ASTM