Applications of Volumetric Absorptive Microsampling Technique: A Systematic Critical Review

被引:16
作者
Dodeja, Prerna [1 ]
Giannoutsos, Spiros [2 ]
Caritis, Steve [3 ]
Venkataramanan, Raman [1 ,4 ,5 ,6 ]
机构
[1] Univ Pittsburgh, Sch Pharm, Dept Pharmaceut Sci, Pittsburgh, PA USA
[2] Univ Pittsburgh, Med Ctr Presbyterian, Dept Pathol, Div Clin Chem,Toxicol & Therapeut Drug Monitoring, Shadyside, PA USA
[3] Univ Pittsburgh, Magee Womens Hosp UPMC, Sch Med, Dept Obstet Gynecol & Reprod Sci, Pittsburgh, PA USA
[4] Univ Pittsburgh, Sch Med, Dept Pathol, Pittsburgh, PA USA
[5] Univ Pittsburgh, Starzl Transplant Inst, Pittsburgh, PA USA
[6] Univ Pittsburgh, Sch Pharm, Dept Pharmaceut Sci, Salk Hall,Room 7354, Pittsburgh, PA 15213 USA
关键词
volumetric absorptive microsampling; dried blood spots; microsampling; VAMS; TANDEM MASS-SPECTROMETRY; DRIED BLOOD SPOTS; WHOLE-BLOOD; LC-MS/MS; QUANTITATIVE BIOANALYSIS; CAPILLARY BLOOD; ANTIEPILEPTIC DRUGS; ALTERNATIVE TOOL; THIAMINE STATUS; HEMATOCRIT;
D O I
10.1097/FTD.0000000000001083
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background:Microsampling is a technique that utilizes a very small volume of biological matrix, typically less than 50 & mu;L, for quantitatively analyzing chemicals, drugs, and biologics. The use of filter paper for blotting blood samples, usually referred to "Dried Blood Spots", is an example of a microsampling approach, which has been established since the early 1960s. However, non-homogeneous sample spread, the influence of hematocrit, improper volume measurement, and environmental degradation are major bottlenecks to the widespread adoption of this technique in routine clinical sample analysis. Novel methods have overcome several of these issues; however, assays using these microsampling tools involve variable steps/approaches.Methods:A novel microsampling device called Volumetric Absorptive microsampling (VAMS), developed in 2014, appears to have resolved the sample inhomogeneity inherent to dried blood spots, with improved precision in the volume of sample collected for measuring drug concentration. A literature search was conducted to identify several analytical and pharmacokinetic studies that have used VAMS in recent years.Results:The key factors for proper experimental design and optimization of the extraction of drugs and metabolites of interest from the device were summarized. This review focuses on VAMS and elaborates on bioanalytical factors, method validation steps, and scope of this technique in clinical practice.Conclusions:The promising microsampling method VAMS is especially suited for conducting pharmacokinetic studies with very small volumes of blood, especially in special patient populations. Clinical validation of every VAMS assay must be conducted prior to the routine practical implementation of this method.
引用
收藏
页码:431 / 462
页数:32
相关论文
共 121 条
  • [1] Validation of methods for determining pediatric midazolam using wet whole blood and volumetric absorptive microsampling
    Abu-Rabie, Paul
    Neupane, Bikalpa
    Spooner, Neil
    Rudge, James
    Denniff, Philip
    Mulla, Hussain
    Pandya, Hitesh
    [J]. BIOANALYSIS, 2019, 11 (19) : 1737 - 1754
  • [2] Simultaneous LC-MS/MS quantification of oxycodone, tramadol and fentanyl and their metabolites (noroxycodone, oxymorphone, O- desmethyltramadol, N- desmethyltramadol, and norfentanyl) in human plasma and whole blood collected via venepuncture and volumetric absorptive micro sampling
    Al-Qurain, Aymen A.
    Williams, Desmond B.
    Mackenzie, Lorraine
    Roberts, Michael S.
    Wiese, Michael D.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 203
  • [3] Volumetric absorptive MicroSampling vs. other blood sampling materials in LC-MS-based protein analysis - preliminary investigations
    Andersen, Ida Kristine Lysgaard
    Rosting, Cecilie
    Gjelstad, Astrid
    Halvorsen, Trine Gronhaug
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 156 : 239 - 246
  • [4] Simultaneous determination of vancomycin and creatinine in plasma applied to volumetric absorptive microsampling devices using liquid chromatography-tandem mass spectrometry
    Andriguetti, Nadine B.
    Lisboa, Leticia L.
    Hahn, Siomara R.
    Pagnussat, Lidiane R.
    Antunes, Marina, V
    Linden, Rafael
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 165 : 315 - 324
  • [5] Giving patients choices: AstraZeneca's evolving approach to patient-centric sampling
    Bailey, Christopher
    Arfvidsson, Cecilia
    Woodford, Lynsey
    de Kock, Mine
    [J]. BIOANALYSIS, 2020, 12 (13) : 957 - 970
  • [6] Volumetric adsorptive microsampling-liquid chromatography tandem mass spectrometry assay for the simultaneous quantification of four antibiotics in human blood: Method development, validation and comparison with dried blood spot
    Barco, Sebastiano
    Castagnola, Elio
    Moscatelli, Andrea
    Rudge, James
    Tripodi, Gino
    Cangemi, Giuliana
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 145 : 704 - 710
  • [7] Capillary blood microsampling to determine serum biopharmaceutical concentration: Mitra® microsampler vs dried blood spot
    Bloem, Karien
    Schaap, Tiny
    Boshuizen, Ronald
    Kneepkens, Eva L.
    Wolbink, Gerrit J.
    de Vries, Annick
    Rispens, Theo
    [J]. BIOANALYSIS, 2018, 10 (11) : 815 - 823
  • [8] Determination of ultra-trace amounts of prosthesis-related metals in whole blood using volumetric absorptive micro-sampling and tandem ICP - Mass spectrometry
    Bolea-Fernandez, Eduardo
    Phan, Kim
    Balcaen, Lieve
    Resano, Martin
    Vanhaecke, Frank
    [J]. ANALYTICA CHIMICA ACTA, 2016, 941 : 1 - 9
  • [9] Capillary Blood Levels of Hydroxychloroquine and Methotrexate Are Stable for up to 5 Years When Collected on Volumetric Absorptive Microsamplers
    Brady, Kelley
    Alexander, Roberta Vezza
    Stimson, Deborah
    Rudolph, Mark
    Kammesheidt, Anja
    [J]. JOURNAL OF APPLIED LABORATORY MEDICINE, 2021, 6 (04) : 858 - 867
  • [10] Therapeutic drug monitoring of anti-epileptic drugs - a clinical verification of volumetric absorptive micro sampling
    Canisius, Thierry P. I. J. M.
    Soons, J. W. P. Hans
    Verschuure, Pauline
    Wammes-van der Heijden, Emmeke A.
    Rouhl, Rob P. W.
    Majoie, H. J. Marian
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (05) : 828 - 835