Nondestructive Tertiary Mill-Scale Thickness Measurement on Commercial Hot-Rolled Steel Strip: Terahertz Time-of-Flight Tomography

被引:1
作者
Zhai, Min [1 ,2 ]
Locquet, Alexandre [1 ,2 ]
Roquelet, Cyrielle [3 ]
Borean, Jean-Luc [3 ]
Meilland, Philip [3 ]
Citrin, David S. S. [1 ,2 ]
机构
[1] Georgia Tech Europe, Georgia Tech, CNRS IRL2958, 2 Rue Marconi, F-57070 Metz, France
[2] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[3] ArcelorMittal Maizieres Res SA, 5BP 7280, F-30320 Maizieres Les Metz, France
关键词
hot-rolled strips; mill scales; nondestructive testing; structural characterization; terahertz imaging; OXIDE-SCALE; SHEET STEEL; OXIDATION; DECONVOLUTION; REDUCTION; IRON;
D O I
10.1002/srin.202300124
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
Measuring mill-scale thickness in a nondestructive and noncontact fashion in a production environment remains a challenge, as knowledge of the thickness is central to processing of the steel strip. Terahertz time-of-flight tomography is demonstrated here to enable nondestructive and noncontact measurements of tertiary mill-scale thickness down to & AP;10 & mu;m on production hot-rolled steel, building on our recent work on thickness evaluation of laboratory-produced scale on steel coupons. X-ray diffraction (XRD) results show that the compositions of the mill-scale films manufactured under production conditions are slightly different from the laboratory-prepared steel coupons, resulting from the different compositions of phases present in the two types of samples. The mill-scale thickness is obtained after advanced signal processing of the raw data and shows good agreement with values obtained from destructive measurements. Compared to conventional techniques, such as scanning electron microscopy which is destructive, eddy current testing, which requires direct contact with the surface of samples investigated and is not suitable for large areas, or elevated temperatures, and acoustic inspection, whose spatial resolution is largely limited by its relatively long-wavelength, terahertz time-of-flight tomography may be implemented for in-line nondestructive thickness characterization and quality control of optically thin tertiary mill scale on steel products, even in a production environment.
引用
收藏
页数:10
相关论文
共 54 条
  • [1] Ali j., 2010, Sys Rev Pharm, V1, P17
  • [2] Characterization and Reduction Behavior of Mill Scale
    Bagatini, Mauricio Covcevich
    Zymla, Victor
    Osorio, Eduardo
    Faria Vilela, Antonio Cezar
    [J]. ISIJ INTERNATIONAL, 2011, 51 (07) : 1072 - 1079
  • [3] Online coating thickness measurement and depth profiling of zinc coated sheet steel by laser-induced breakdown spectroscopy
    Balzer, H
    Hoehne, M
    Sturm, V
    Noll, R
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (7-8) : 1172 - 1178
  • [4] STUDY OF MAGNETITE FILM FORMATION AT METAL-SCALE INTERFACE DURING COOLING OF STEEL PRODUCTS
    BAUD, J
    FERRIER, A
    MANENC, J
    [J]. OXIDATION OF METALS, 1978, 12 (04): : 331 - 342
  • [5] QUANTITATIVE PHASE-ANALYSIS USING THE RIETVELD METHOD
    BISH, DL
    HOWARD, SA
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1988, 21 (02) : 86 - 91
  • [6] Understanding the properties of oxide scales on hot rolled steel strip
    Bolt, PH
    [J]. STEEL RESEARCH INTERNATIONAL, 2004, 75 (06): : 399 - 404
  • [7] Nonuniform Manual Scanning for Rapid Microwave Nondestructive Evaluation Imaging
    Case, Joseph T.
    Ghasr, Mohammad Tayeb
    Zoughi, Reza
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (05) : 1250 - 1258
  • [8] THICKNESS MEASUREMENT OF THIN-FILMS BY X-RAY ABSORPTION
    CHAUDHURI, J
    SHAH, S
    [J]. JOURNAL OF APPLIED PHYSICS, 1991, 69 (01) : 499 - 501
  • [9] Examination of oxide scales of hot rolled steel products
    Chen, RY
    Yuen, WYD
    [J]. ISIJ INTERNATIONAL, 2005, 45 (01) : 52 - 59
  • [10] Review of the high-temperature oxidation of iron and carbon steels in air or oxygen
    Chen, RY
    Yuen, WYD
    [J]. OXIDATION OF METALS, 2003, 59 (5-6): : 433 - 468