A label-free colorimetric 3D paper-based device for ochratoxin A detection using G-quadruplex/hemin DNAzyme with a smartphone readout

被引:10
|
作者
Zhang, Xiaobo [1 ,2 ,3 ]
Wang, Fengya [1 ,3 ]
Zhi, Hui [1 ]
Wan, Peng [4 ]
Feng, Liang [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Dept Instrumentat & Analyt Chem, CAS Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China
[2] Dalian Minzu Univ, Sch Life Sci, Key Lab Biotechnol & Bioresources Utilizat, Minist Educ, Dalian 116600, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Dalian Univ Technol, Instrumental Anal Ctr, Dalian 116024, Peoples R China
关键词
Colorimetric sensor; Ochratoxin A; Paper-based analytical device; G-quadruplex; DNAzyme; CATALYTIC-ACTIVITY; MYCOTOXINS; ASSAY; LEAD;
D O I
10.1016/j.talanta.2023.124603
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The colorimetric sensor usually depends on enzyme-mediated signal amplification to achieve trace analysis of ochratoxin A (OTA) residues in food samples. However, the enzyme labeling and manual addition of reagents steps increased assay time and operation complexity, restricting their application in point-of-care testing (POCT). Herein, we report a label-free colorimetric device integrating a 3D paper-based analytical device and a smart-phone as handheld readout for rapid and sensitive detection of OTA. Using vertical-flow design, the paper-based analytical device enables the specific recognition of target and self-assembly of G-quadruplex (G4)/hemin DNAzyme to be performed, then employs DNAzyme for transducing the OTA binding event signal into a colorimetric signal. The design of independent functional units, including biorecognition unit, self-assembly unit and colorimetric units, which can address crowding and disorder of biosensing interfaces and improve the recognition efficiency of aptamer (apta). In addition, we eliminated signal losses and nonuniform coloring by introducing carboxymethyl chitosan (CMCS) to obtain perfectly focused signals on colorimetric unit. On the basis of parameter optimization, the device exhibited a detection range of 0.1-500 ng/mL and a detection limit of 41.9 pg/mL for OTA. Importantly, good results were obtained in spiked real samples, indicating applicability and reliability of developed device.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Binding-induced and label-free colorimetric method for protein detection based on autonomous assembly of hemin/G-quadruplex DNAzyme amplification strategy
    Wu, Hao
    Zhang, Kai
    Liu, Yaling
    Wang, Hongyong
    Wu, Jun
    Zhu, Feifan
    Zou, Pei
    BIOSENSORS & BIOELECTRONICS, 2015, 64 : 572 - 578
  • [2] Label-free colorimetric detection platform based on catalytic hairpin self-assembly and G-quadruplex/hemin DNAzyme for comprehensive biomarker profiling
    Li, Changjiang
    Hu, Yuqiang
    Shi, Tianzi
    Dong, Kejun
    Wu, Tongbo
    TALANTA, 2024, 272
  • [3] G-quadruplex DNAzyme based molecular catalytic beacon for label-free colorimetric logic gates
    Zhu, Jinbo
    Li, Tao
    Zhang, Libing
    Dong, Shaojun
    Wang, Erkang
    BIOMATERIALS, 2011, 32 (30) : 7318 - 7324
  • [4] Label-free colorimetric detection of coralyne utilizing peroxidase-like split G-quadruplex DNAzyme
    Hou, Ting
    Li, Chunxiang
    Wang, Xiuzhong
    Zhao, Can
    Li, Feng
    ANALYTICAL METHODS, 2013, 5 (18) : 4671 - 4674
  • [5] Timing readout in paper device for quantitative point-of-use hemin/G-quadruplex DNAzyme-based bioassays
    Zhang, Yun
    Fan, Jinlong
    Nie, Jinfang
    Le, Shangwang
    Zhu, Wenyuan
    Gao, Dong
    Yang, Jiani
    Zhang, Songbai
    Li, Jianping
    BIOSENSORS & BIOELECTRONICS, 2015, 73 : 13 - 18
  • [6] Colorimetric detection of furin based on enhanced catalytic activity of G-quadruplex/hemin DNAzyme
    Shi, Liu
    Wang, Lin
    Yu, Xiaomeng
    Kuang, Deqi
    Huang, Yue
    Yang, Nana
    Yang, Jie
    Li, Genxi
    ANALYTICA CHIMICA ACTA, 2024, 1323
  • [7] Label Free Detection of Adenosine Based on Hemin/G-Quadruplex Peroxidase-Mimicking DNAzyme as Bioelectrocatalyst
    Li, Yu
    Li, Sen
    Xia, Ge-Qing
    Wang, Yuansheng
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (18) : 10541 - 10545
  • [8] Engineering DNA G-quadruplex assembly for label-free detection of Ochratoxin A in colorimetric and fluorescent dual modes
    He, Kaiyu
    Sun, Liping
    Wang, Liu
    Li, Wang
    Hu, Guixian
    Ji, Xiaofeng
    Zhang, Yiming
    Xu, Xiahong
    JOURNAL OF HAZARDOUS MATERIALS, 2022, 423
  • [9] Sensitive and label-free electrochemical lead ion biosensor based on a DNAzyme triggered G-quadruplex/hemin conformation
    Wang, LeLe
    Wen, Yanli
    Li, Lanying
    Yang, Xue
    Jia, Nengqin
    Li, Wen
    Meng, Jiaoran
    Duan, Manlei
    Sun, Xiaoguang
    Liu, Gang
    BIOSENSORS & BIOELECTRONICS, 2018, 115 : 91 - 96
  • [10] A label-free hemin/G-quadruplex DNAzyme biosensor developed on electrochemically modified electrodes for detection of a HBV DNA segment
    Shi, Lijuan
    Yu, Yanyan
    Chen, Zuanguang
    Zhang, Lin
    He, Sijing
    Shi, Qiujia
    Yang, Hongzhi
    RSC ADVANCES, 2015, 5 (15): : 11541 - 11548