Numerical investigation and design for the local buckling behaviour of high strength steel hexagonal hollow section stub columns under axial compression

被引:12
作者
Liu, Jun-zhi [1 ,3 ]
Fang, Han [2 ]
Guo, Jiachen [3 ]
Li, Shuai [3 ]
Chan, Tak-Ming [3 ,4 ]
机构
[1] Beijing Normal Univ, Sch Natl Safety & Emergency Management, Zhuhai, Peoples R China
[2] Univ Leeds, Sch Civil Engn, Leeds, England
[3] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China
[4] Hong Kong Polytech Univ, Chinese Natl Engn Res Ctr Steel Construct, Hong Kong Branch, Hong Kong, Peoples R China
关键词
High strength steel; Local buckling behaviour; Hexagonal hollow section stub columns; Numerical modelling; Design approaches; COLD-FORMED STEEL; BOX COLUMNS; PERFORMANCE; STRESS; TUBES;
D O I
10.1016/j.tws.2023.110717
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The local buckling behaviour of high strength steel (HSS) hexagonal hollow section (HexHS) stub columns encompassing three different fabrication routes under axial compression is numerically investigated in this study. Finite-element (FE) models were developed and validated against the experimental results. The validated FE models were subsequently employed to carry out parametric studies to expand structural performance data covering a wider range of geometries and cross-section slenderness as well as two different steel grades. The obtained results from FE models in line with the experimental data were used to evaluate the applicability of the existing design codes and the design approaches in literature to HSS HexHS under pure compression. The comparison indicates that the current slenderness yield limiting values in design codes cannot be simply extended to HSS HexHS stub columns. All the design codes exhibit a high degree of conservatism due to the lack of consideration for strain hardening whereas the Continuous Strength Method (CSM) was found to provide more accurate predictions than the Direct Strength Method (DSM). Modified design approaches are proposed to improve the accuracy of the strength predictions for HSS HexHS stub columns.
引用
收藏
页数:18
相关论文
共 70 条
[1]  
[Anonymous], 2007, EN 1993--1-12, Eurocode 3: Design of Steel structures-Part 1.12:-Design of steel structures-Part 1-12: Additional rules for the extension of EN 1993 up to steel grades S700
[2]  
[Anonymous], 2011, 4811 ASCESEI
[3]  
[Anonymous], 2005, EN 1993-1-1, DOI DOI 10.1017/CBO9781107415324.004
[4]  
[Anonymous], ABAQUS STANDARD VERS
[5]  
[Anonymous], 2020, PREN199311 CEN
[6]  
[Anonymous], 2006, EN 1993-1-5, Eurocode 3: Design of Steel Structures - Part 1-5: Plated Structural Elements
[7]  
[Anonymous], 2016, AISC 360 16
[8]  
[Anonymous], 2016, AS 4100-1998(R2016)
[9]  
[Anonymous], 2002, EN 1990
[10]  
Baddoo N., 2020, HIGH STRENGTH STEEL, V398