Usefulness of silent magnetic resonance angiography for intracranial aneurysms treated with a flow re-direction endoluminal device

被引:2
|
作者
Suzuki, Tomoaki [1 ,3 ]
Hasegawa, Hitoshi [1 ]
Okamoto, Kouichirou [2 ]
Ando, Kazuhiro [1 ]
Shibuya, Kouhei [1 ]
Takahashi, Haruhiko [1 ]
Saito, Shoji [1 ]
Fujiwara, Hidemoto [1 ]
Oishi, Makoto [1 ]
Fujii, Yukihiko [1 ]
机构
[1] Niigata Univ, Brain Res Inst, Dept Neurosurg, Niigata, Japan
[2] Niigata Univ, Brain Res Inst, Dept Translat Res, Niigata, Japan
[3] Niigata Univ, Brain Res Inst, Dept Neurosurg, 1-757 Asahimachi Dori, Niigata 9518585, Japan
基金
日本学术振兴会;
关键词
Flow re-direction endoluminal device; intracranial aneurysm; silent magnetic resonance angiography; time-of-flight magnetic resonance angiography; ultra-short echo time magnetic resonance angiography; ASSISTED COIL EMBOLIZATION; ENCODING TIME REDUCTION; ENHANCED MR-ANGIOGRAPHY; FOLLOW-UP; RADIAL ACQUISITION; OF-FLIGHT; STENT; SCAN;
D O I
10.1177/15910199231174546
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Flow re-direction endoluminal device (FRED) is a novel dual-layer flow-diverting stent to treat cerebral aneurysms with high obliteration rates, however, it induces inevitable metal-related artifacts. We compared silent magnetic resonance angiography (MRA), a new MRA method using ultra-short time of echo and arterial spin-labeling, with conventional time-of-flight (TOF)-MRA for imaging aneurysms treated using FRED. Methods Between May 2020 and September 2022, 16 patients with unruptured internal carotid aneurysms treated using FRED simultaneously underwent silent MRA and TOF-MRA after treatment, with 36 follow-up sessions in total. Two observers independently graded the quality of intra-aneurysmal flow and stented parent arteries under both types of MRA from 1 (not visible) to 4 (nearly equal to digital subtraction angiography [DSA]), with reference to DSA images as a standard criterion. Results The mean scores for intra-aneurysmal flow and stented parent arteries were significantly better for silent MRA (3.93 +/- 0.21 and 3.82 +/- 0.32, respectively) than for TOF-MRA (2.08 +/- 0.99 and 1.92 +/- 0.79, respectively) (P < 0.01). Intermodality agreements for intra-aneurysmal flow and stented parent arteries were 0.87 and 0.90, respectively. Conclusion Silent MRA is superior to TOF-MRA for assessing patients treated with FRED, with potential as an alternative imaging modality to DSA.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Diagnosis of Unruptured Intracranial Aneurysms Using Proton-Density Magnetic Resonance Angiography : A Comparison With High-Resolution Time-of-Flight Magnetic Resonance Angiography
    Suh, Pae Sun
    Jung, Seung Chai
    Moon, Hye Hyeon
    Roh, Yun Hwa
    Song, Yunsun
    Kim, Minjae
    Lee, Jungbok
    Choi, Keum Mi
    KOREAN JOURNAL OF RADIOLOGY, 2024, 25 (06) : 575 - 588
  • [42] Multicenter analysis of the incidence of in-stent stenosis following the deployment of flow-redirection endoluminal device in the treatment of intracranial aneurysms
    Gajjar, Avi A.
    Sioutas, Georgios S.
    Custozzo, Amanda
    Salem, Mohamed M.
    Field, Nicholas C.
    Shekhtman, Oleg
    Davis, Pierce
    Prabhala, Tarun
    Jankowitz, Brian T.
    Dalfino, John C.
    Boulos, Alan S.
    Burkhardt, Jan-Karl
    Paul, Alexandra R.
    Srinivasan, Visish M.
    INTERVENTIONAL NEURORADIOLOGY, 2025,
  • [43] Ultra-short Echo-time MR Angiography Combined with a Subtraction Method to Assess Intracranial Aneurysms Treated with a Flow-diverter Device
    Ayabe, Yusuke
    Hamamoto, Kohei
    Yoshino, Yoshikazu
    Ikeda, Yoshimasa
    Chiba, Emiko
    Yuzawa, Hironao
    Oyama-Manabe, Noriko
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2023, 22 (01) : 117 - 125
  • [44] The implications of magnetic resonance angiography artifacts caused by different types of intracranial flow diverters
    Halitcan, Batur
    Bige, Sayin
    Sinan, Balci
    Ilkay, Akmangit
    Ergun, Daglioglu
    Fatih, Alagoz
    Anil, Arat
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [45] 3-DIMENSIONAL DISPLAY OF THE ORIFICE OF INTRACRANIAL ANEURYSMS - A NEW POTENTIAL APPLICATION FOR MAGNETIC-RESONANCE ANGIOGRAPHY
    BONTOZOGLOU, N
    SPANOS, H
    LASJAUNIAS, P
    ZARIFIS, G
    NEURORADIOLOGY, 1994, 36 (05) : 346 - 349
  • [46] Comparison between pipeline embolization device (PED) versus flow redirection endoluminal device (FRED) for intracranial aneurysms: a comprehensive systematic review and meta-analysis
    Seyed Farzad Maroufi
    Mohammad Sadegh Fallahi
    Muhammad Waqas
    Othman Bin-Alamer
    Manisha Koneru
    Joanna M Roy
    Jane Khalife
    Hamza A. Shaikh
    Daniel A. Tonetti
    Neurosurgical Review, 48 (1)
  • [47] Compressed sensing time-of-flight magnetic resonance angiography with high spatial resolution for evaluating intracranial aneurysms: comparison with digital subtraction angiography
    Kim, Donghyun
    Heo, Young Jin
    Jeong, Hae Woong
    Baek, Jin Wook
    Shin, Gi Won
    Jin, Sung-Chul
    Baek, Hye Jin
    Ryu, Kyeong Hwa
    Kim, Kang Soo
    Kim, InSeong
    NEURORADIOLOGY JOURNAL, 2021, 34 (03) : 213 - 221
  • [48] Diagnostic Accuracy of Magnetic Resonance Angiography in Prediction of Intracranial Aneurysms in Post-Coiling Patients Taking Digital Subtraction Angiography as Gold Standard
    Bhatti, Shahzad Karim
    Amber, Ambreen
    Rashid, Umair
    Khalid, Abdullah
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2020, 14 (04): : 1027 - 1029
  • [49] Follow-Up Assessment of Intracranial Aneurysms Treated with Endovascular Coiling: Comparison of Compressed Sensing and Parallel Imaging Time-of-Flight Magnetic Resonance Angiography
    Vornetti, Gianfranco
    Bartiromo, Fiorina
    Toni, Francesco
    Dall'Olio, Massimo
    Cirillo, Mario
    Speier, Peter
    Princiotta, Ciro
    Schmidt, Michaela
    Tonon, Caterina
    Zaca, Domenico
    Lodi, Raffaele
    Cirillo, Luigi
    TOMOGRAPHY, 2022, 8 (03) : 1608 - 1617
  • [50] Non-enhanced magnetic resonance imaging of unruptured intracranial aneurysms at 7 Tesla: Comparison with digital subtraction angiography
    Wrede, Karsten H.
    Matsushige, Toshinori
    Goericke, Sophia L.
    Chen, Bixia
    Umutlu, Lale
    Quick, Harald H.
    Ladd, Mark E.
    Johst, Soeren
    Forsting, Michael
    Sure, Ulrich
    Schlamann, Marc
    EUROPEAN RADIOLOGY, 2017, 27 (01) : 354 - 364