Usefulness of silent magnetic resonance angiography for intracranial aneurysms treated with a flow re-direction endoluminal device

被引:2
|
作者
Suzuki, Tomoaki [1 ,3 ]
Hasegawa, Hitoshi [1 ]
Okamoto, Kouichirou [2 ]
Ando, Kazuhiro [1 ]
Shibuya, Kouhei [1 ]
Takahashi, Haruhiko [1 ]
Saito, Shoji [1 ]
Fujiwara, Hidemoto [1 ]
Oishi, Makoto [1 ]
Fujii, Yukihiko [1 ]
机构
[1] Niigata Univ, Brain Res Inst, Dept Neurosurg, Niigata, Japan
[2] Niigata Univ, Brain Res Inst, Dept Translat Res, Niigata, Japan
[3] Niigata Univ, Brain Res Inst, Dept Neurosurg, 1-757 Asahimachi Dori, Niigata 9518585, Japan
基金
日本学术振兴会;
关键词
Flow re-direction endoluminal device; intracranial aneurysm; silent magnetic resonance angiography; time-of-flight magnetic resonance angiography; ultra-short echo time magnetic resonance angiography; ASSISTED COIL EMBOLIZATION; ENCODING TIME REDUCTION; ENHANCED MR-ANGIOGRAPHY; FOLLOW-UP; RADIAL ACQUISITION; OF-FLIGHT; STENT; SCAN;
D O I
10.1177/15910199231174546
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Flow re-direction endoluminal device (FRED) is a novel dual-layer flow-diverting stent to treat cerebral aneurysms with high obliteration rates, however, it induces inevitable metal-related artifacts. We compared silent magnetic resonance angiography (MRA), a new MRA method using ultra-short time of echo and arterial spin-labeling, with conventional time-of-flight (TOF)-MRA for imaging aneurysms treated using FRED. Methods Between May 2020 and September 2022, 16 patients with unruptured internal carotid aneurysms treated using FRED simultaneously underwent silent MRA and TOF-MRA after treatment, with 36 follow-up sessions in total. Two observers independently graded the quality of intra-aneurysmal flow and stented parent arteries under both types of MRA from 1 (not visible) to 4 (nearly equal to digital subtraction angiography [DSA]), with reference to DSA images as a standard criterion. Results The mean scores for intra-aneurysmal flow and stented parent arteries were significantly better for silent MRA (3.93 +/- 0.21 and 3.82 +/- 0.32, respectively) than for TOF-MRA (2.08 +/- 0.99 and 1.92 +/- 0.79, respectively) (P < 0.01). Intermodality agreements for intra-aneurysmal flow and stented parent arteries were 0.87 and 0.90, respectively. Conclusion Silent MRA is superior to TOF-MRA for assessing patients treated with FRED, with potential as an alternative imaging modality to DSA.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Abnormal foreshortening of a Flow Re-Direction Endoluminal Device caused by in-stent thrombosis immediately after deployment br
    Otsuka, Takafumi
    Izumi, Takashi
    Nishihori, Masahiro
    Tsukada, Tetsuya
    Goto, Shunsaku
    Ikezawa, Mizuka
    Kato, Naoki
    Nakano, Mizuki
    Uda, Kenji
    Yokoyama, Kinya
    Araki, Yoshio
    Saito, Ryuta
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2022, 84 (04) : 884 - 889
  • [22] Limitations of magnetic resonance imaging and magnetic resonance angiography in the diagnosis of intracranial aneurysms
    Schwab, Kristin E.
    Gailloud, Philippe
    Wyse, Gerald
    Tamargo, Rafael J.
    NEUROSURGERY, 2008, 63 (01) : 29 - 34
  • [23] A single-centre experience and literature review of Flow Re-Directional Endoluminal Device (FRED) in endovascular treatment of intracranial aneurysms
    Gan, C. L.
    Yang, Z.
    Salahia, G.
    Halpin, S.
    Nair, S.
    CLINICAL RADIOLOGY, 2021, 76 (03) : 238.e1 - 238.e8
  • [24] Fenestrations accompanied by intracranial aneurysms assessed with magnetic resonance angiography
    Sun, Zhen-Kui
    Li, Mei
    Li, Ming-Hua
    Li, Yong-Dong
    Sun, Wen-Ping
    Thu, Yue-Qi
    NEUROLOGY INDIA, 2012, 60 (01) : 45 - 49
  • [25] CT Angiography in Occlusion Assessment of Intracranial Aneurysms Treated with the WEB Device
    Ozpeynirci, Yigit
    Braun, Michael
    Schmitz, Bernd
    JOURNAL OF NEUROIMAGING, 2019, 29 (04) : 481 - 486
  • [26] Assessing the Hemodynamics in Residual Cavities of Intracranial Aneurysm after Coil Embolization with Combined Computational Flow Dynamics and Silent Magnetic Resonance Angiography
    Suzuki, Tomoaki
    Genkai, Nobuyuki
    Nomura, Toshiharu
    Abe, Hiroshi
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2020, 29 (12)
  • [27] Intracranial Aneurysms Treated by Flow-Diverting Stents: Long-Term Follow-Up with Contrast-Enhanced Magnetic Resonance Angiography
    Maximilian Patzig
    Robert Forbrig
    Lorenz Ertl
    Hartmut Brückmann
    Gunther Fesl
    CardioVascular and Interventional Radiology, 2017, 40 : 1713 - 1722
  • [28] Intracranial Aneurysms Treated by Flow-Diverting Stents: Long-Term Follow-Up with Contrast-Enhanced Magnetic Resonance Angiography
    Patzig, Maximilian
    Forbrig, Robert
    Ertl, Lorenz
    Brueckmann, Hartmut
    Fesl, Gunther
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 40 (11) : 1713 - 1722
  • [29] Detection and Characterization of Intracranial Aneurysms: Magnetic Resonance Angiography Versus Digital Subtraction Angiography
    Shahzad, Rafia
    Younas, Farhana
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2011, 21 (06): : 325 - 329
  • [30] MAGNETIC-RESONANCE ANGIOGRAPHY OF INTRACRANIAL ANEURYSMS - COMPARISON WITH INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY
    SCHUIERER, G
    HUK, WJ
    LAUB, G
    NEURORADIOLOGY, 1992, 35 (01) : 50 - 54