Prosthesis-Patient Mismatch after Aortic Valve Replacement with the Mosaic Ultra Bioprosthesis

被引:0
作者
Ntinopoulos, Vasileios [1 ]
Biefer, Hector Rodriguez Cetina [1 ]
Dushaj, Stak [1 ]
Rings, Laura [1 ]
Fleckenstein, Philine [1 ]
Dzemali, Omer [1 ,2 ]
Haeussler, Achim [1 ]
机构
[1] City Hosp Zurich, Dept Cardiac Surg, Zurich, Switzerland
[2] City Hosp Zurich, Dept Cardiac Surg, CH-8063 Zurich, Switzerland
关键词
aortic valve and root; heart valve surgery; outcomes; CLINICAL IMPACT; HEMODYNAMICS; PERFORMANCE; PERIMOUNT; SURVIVAL; POSITION;
D O I
10.1055/s-0043-1768033
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Several studies have reported high rates of prosthesis-patient mismatch (PPM) after aortic valve replacement (AVR) with the Mosaic prosthesis. This work assesses the incidence of PPM after AVR with a modified version of the Mosaic prosthesis, the Mosaic Ultra.Methods We performed a retrospective analysis of the data of 532 patients who underwent AVR with implantation of the Mosaic Ultra prosthesis in the period 2007-2016 in our institution. Patients were classified according to their indexed effective orifice area (EOAi) to severe (EOAi < 0.65 cm (2) /m (2) ), moderate (EOAi 0.65-0.85 cm (2) /m (2) ), and absent/mild PPM (EOAi > 0.85 cm (2) /m (2) ). In-hospital postoperative outcomes and the impact of PPM on mean transvalvular pressure gradient after stratification by prosthesis size were assessed.Results Overall, 3 (0.6%) patients had severe, 92 (17.3%) moderate, and 437 (82.1%) absent/mild PPM. There was a significant difference in PPM proportions (moderate/severe vs absent/mild PPM) across different prosthesis sizes overall ( p < 0.0001), observing gradually increasing rates of PPM with decreasing prosthesis sizes. Patients with moderate/severe PPM had higher mean transvalvular pressure gradients (19 [13-25] vs 13 [10-17] mm Hg, p < 0.0001) than patients with absent/mild PPM. There was a significant difference in mean transvalvular pressure gradient between the different aortic valve prosthesis sizes overall ( p < 0.0001), observing gradually increasing gradients with decreasing prosthesis sizes.Conclusion Patients undergoing AVR with the smaller sized (19, 21, and 23 mm) Mosaic Ultra aortic valve prostheses exhibit a higher risk for moderate/severe PPM and higher mean aortic transvalvular pressure gradients than patients receiving the larger sized (25, 27, and 29 mm) prostheses.
引用
收藏
页码:197 / 204
页数:8
相关论文
共 21 条
[1]   Long-term results of the Medtronic Mosaic porcine bioprosthesis in the aortic position [J].
Anselmi, Amedeo ;
Flecher, Erwan ;
Ruggieri, Vito Giovanni ;
Harmouche, Majid ;
Langanay, Thierry ;
Corbineau, Herve ;
Verhoye, Jean-Philippe ;
Leguerrier, Alain .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (06) :1884-1891
[2]   Echo/Doppler Evaluation of Hemodynamics After Aortic Valve Replacement Principles of Interrogation and Evaluation of High Gradients [J].
Bach, David S. .
JACC-CARDIOVASCULAR IMAGING, 2010, 3 (03) :296-304
[3]   Patient-prosthesis mismatch following aortic valve replacement [J].
Bilkhu, Rajdeep ;
Jahangiri, Marjan ;
Otto, Catherine M. .
HEART, 2019, 105 :S28-S33
[4]   Hemodynamic comparison of Bioprostheses for complete supra-annular position in patients with small aortic annulus [J].
Botzenhardt, F ;
Eichinger, WB ;
Bleiziffer, S ;
Guenzinger, R ;
Wagner, IM ;
Bauernschmitt, R ;
Lange, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (12) :2054-2060
[5]   Trifecta has lower gradient and less prosthesis-patient mismatch than Mosaic Ultra in the aortic position: A prospective randomized study [J].
Braathen, Bjorn ;
Husebye, Trygve ;
Lunde, Ida G. ;
Tonnessen, Theis .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 158 (04) :1032-1039
[6]  
Dalmau Maria Jose, 2007, Interact Cardiovasc Thorac Surg, V6, P345, DOI 10.1510/icvts.2006.144196
[7]   Comparison of early haemodynamics of 19-mm aortic valve bioprostheses in patients with a small aortic annulus [J].
Domoto, Satoru ;
Niinami, Hiroshi ;
Uwabe, Kazuhiko ;
Koike, Hiroyuki ;
Tabata, Mimiko ;
Morita, Kozo ;
Kambe, Masaru ;
Iguchi, Atsushi .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 22 (01) :19-25
[8]   Exercise hemodynamics of bovine versus porcine bioprostheses: A prospective randomized comparison of the Mosaic and Perimount aortic valves [J].
Eichinger, WB ;
Botzenhardt, F ;
Keithahn, A ;
Guenzinger, R ;
Bleiziffer, S ;
Wagner, I ;
Bauernschmitt, R ;
Lange, R .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 129 (05) :1056-1063
[9]   Mosaic valve international clinical trial: Early performance results [J].
Fradet, GJ ;
Bleese, N ;
Burgess, J ;
Cartier, PC .
ANNALS OF THORACIC SURGERY, 2001, 71 (05) :S273-S277
[10]   Late haemodynamic performance and survival after aortic valve replacement with the Mosaic bioprosthesis [J].
Glaser, Natalie ;
Franco-Cereceda, Anders ;
Sartipy, Ulrik .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 19 (05) :756-762