Experimental and Numerical Investigation of Steel- and GFRP-Reinforced Concrete Beams Subject to Fire Exposure

被引:9
作者
Thongchom, Chanachai [1 ]
Bui, Linh Van Hong [2 ]
Poonpan, Natthanuch [1 ]
Phudtisarigorn, Natcha [1 ]
Nguyen, Phuoc Trong [3 ]
Keawsawasvong, Suraparb [1 ]
Mousa, Saeed [4 ]
机构
[1] Thammasat Univ, Fac Engn, Thammasat Sch Engn, Dept Civil Engn, Pathum Thani 12120, Thailand
[2] Tokyo City Univ, Adv Retrofit Technol Int Ctr, Adv Res Labs, 1-28-1 Tamazutsumi, Tokyo 1588557, Japan
[3] Ho Chi Minh City Open Univ, Fac Civil Engn, 97 Vo Van Tan,Dist 3, Ho Chi Minh City 700000, Vietnam
[4] Jazan Univ, Fac Engn, Jazan 706, Saudi Arabia
关键词
glass fiber-reinforced polymer; fire resistance; concrete beam; finite element; fire; RESISTANCE; STRENGTH; TEMPERATURE; PERFORMANCE; STIFFNESS; BARS;
D O I
10.3390/buildings13030609
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates the behavior of three concrete beams reinforced with steel and GFRP bars under fire exposure. The fire tests of three beams were conducted including one control steel-reinforced concrete (RC) beam and two GFRP-RC beams. The beams were exposed to fire according to the standard fire curve ISO 834 for 3 h. The investigation parameters included the reinforcement types (i.e., steel and GFRP bars) and diameter of GFRP bars. Based on the experimental results, during fire exposure, the deflection rate of the steel-RC beam was lower than the ones reinforced with GFRP bars. The critical temperatures measured at steel and GFRP bars in the steel-RC and GFRP-RC beams were 593 degrees C and 300-330 degrees C, respectively along with the fire durations of 83 and 33-36.4 min, respectively. The different GFRP bar sizes did not affect the fire resistance process. The steel-RC beam had greater fire resistance than the GFRP-RC beams. All test specimens had a fire resistance time lower than two hours. In addition, the 2D simplified finite element method (FEM) using commercial software ANSYS was performed to predict the thermal response of the beam section. Compared with experimental results, the FE model can reasonably predict the thermal responses of the beam sections.
引用
收藏
页数:19
相关论文
共 44 条
[1]  
Al-Thairy H., 2020, IOP C SERIES MAT SCI, VVolume 888, P012012
[2]   Performance of glass fiber reinforced polymer bars under elevated temperatures [J].
Alsayed, Saleh ;
Al-Salloum, Yousef ;
Almusallam, Tarek ;
El-Gamal, Sherif ;
Aqel, Mohammed .
COMPOSITES PART B-ENGINEERING, 2012, 43 (05) :2265-2271
[3]  
[Anonymous], 2016, 242559 TISI
[4]  
[Anonymous], 1999, 13407 ISO, P1
[5]  
[Anonymous], 2021, ASTMstandard D7205/D7205M: Standard test method for tensile properties of fiber reinforced polymer matrix composite bars
[6]  
[Anonymous], 2016, 202559 TISI
[7]  
[Anonymous], 2004, 199212 EN
[8]  
[Anonymous], 2022, A370 ASTM
[9]  
[Anonymous], 2008, E11908A ASTM
[10]  
[Anonymous], 2016, C39C39M16B ASTM