A Monte Carlo simulation model to determine the effective concrete materials for fast neutron shielding

被引:12
|
作者
Paul, Mannu Bardhan [1 ]
Ankan, Anirban Dutta [2 ,3 ]
Deb, Himadri [4 ]
Ahasan, M. Monjur [5 ]
机构
[1] Bangladesh Atom Energy Commiss, Inst Nucl Med Phys, Cyclotron Div, Dhaka, Bangladesh
[2] Chittagong Univ Engn & Technol, Dept CSE, Chittagong, Bangladesh
[3] Samsung R&D Inst Bangladesh Ltd, Wearable Experience Grp, Dhaka, Bangladesh
[4] Jahangirnagar Univ, Dept Phys, Savar Union, Bangladesh
[5] Bangladesh Atom Energy Commiss, Med Phys Div, Dhaka, Bangladesh
关键词
Monte Carlo simulation; Fast neutron; Shielding calculation; Concrete bunker; Cyclotron vault;
D O I
10.1016/j.radphyschem.2022.110476
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Concretes are popularly used as shielding materials in nuclear radiation facilities. Special concrete features are employed in the facilities where Fast neutrons, including corresponding `prompt gamma' rays, are prevalent. The conventional shielding calculations for fast neutrons are complicated and constrained with energy-limited formulas. In this research work, a concrete bunker model has been developed with a variety of compositions and densities. Eleven following appropriate composite materials were used in this case; G4_C (2.3), Ordinary (2.5), Barytes BA-a (3.5), Magnetite M-a (3.55), Ilmenite I-Ia (3.5), Limonite with Steel Punch LS-a (4.54), (80% G4_C+20%Fe+10%B) Mix-1 (2.9), (80%G4_C+20%B4C) Mix-2 (2.35), (80%G4_C+20%BaSO4) Mix-3 (2.74), Serpentine (3) and Serpentine (3.3). Depth-dose profiles for each concrete composition were investigated by Monte Carlo simulation, subjected against an 18.5 MeV neutron source. Shielding properties, like Relaxation lengths, Half Value Layers, and Tenth Value Layers have been deduced harnessing these data. The most efficient materials for shielding fast neutrons regarding half value layers found for the two physics lists, QGSP_BERT_HP and Shielding, successively are, 5.78 and 12.48 cm for Serpentine (3.3), 14.88 and 9.18 cm for Ilmenite I-Ia (3.5), 14.28 and 25.18 cm for Limonite with Steel Punch LS-a (4.54), and 13.58 and 13.48 cm for (80%G4_C+20% Fe+10%B) Mix-1 (2.9). This model could be used to determine the radiation shielding parameters made of any kind of materials and composites using different sources of radiation.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Monte-Carlo aided design of neutron shielding concretes
    Tefelski, D. B.
    Piotrowski, T.
    Blideanu, V.
    Polanski, A.
    Skubalski, J.
    BULLETIN OF THE POLISH ACADEMY OF SCIENCES-TECHNICAL SCIENCES, 2013, 61 (01) : 161 - 171
  • [22] REACTOR CAVITY FAST-NEUTRON STREAMING CALCULATION AND SHIELDING DESIGN BY MONTE-CARLO TECHNIQUES
    YANG, TL
    IOTTI, RC
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1975, 22 (NOV16): : 806 - 806
  • [23] Monte Carlo simulation of effect of neutron scattering on image information in 14 MeV fast neutron radiography
    Zhang Fa-Qiang
    Yang Jian-Lun
    Li Zheng-Hong
    Ying Chun-Tong
    Lu Guang-Jun
    ACTA PHYSICA SINICA, 2007, 56 (06) : 3577 - 3583
  • [24] Monte Carlo simulation of biological shielding parameters in PGNAA
    Yang, Jianbo
    Peng, Kexin
    Qiao, Yujie
    Zhang, Can
    Li, Rui
    Li, Zhe
    MICRO & NANO LETTERS, 2018, 13 (04): : 457 - 460
  • [25] Monte Carlo simulation of fast neutron-induced fission of 237Np
    Liu, Chang-Qi
    Wei, Zheng
    Han, Chao
    Huang, Chang
    Huang, Zhi-Wu
    Ma, Zhan-Wen
    Zhang, Shuang-Jiao
    Peng, Shao-Hua
    Li, Wei-Min
    Bai, Xiao-Hou
    Wang, Jun-Run
    Lu, Xiao-Long
    Zhang, Yu
    Xu, Da-Peng
    Su, Xiao-Dong
    Yao, Ze-En
    CHINESE PHYSICS C, 2019, 43 (06)
  • [26] Monte Carlo simulation of fast neutron-induced fission of 237Np
    刘昌奇
    韦峥
    韩超
    黄畅
    黄智武
    马占文
    张双佼
    彭少华
    李卫敏
    白晓厚
    王俊润
    卢小龙
    张宇
    徐大鹏
    苏小东
    姚泽恩
    Chinese Physics C, 2019, 43 (06) : 18 - 24
  • [27] Monte Carlo simulation of neutron thermalization in matter
    Peralta, L
    EUROPEAN JOURNAL OF PHYSICS, 2002, 23 (03) : 307 - 314
  • [28] Fast update algorithm for the quantum Monte Carlo simulation of the Hubbard model
    Nukala, Phani K. V. V.
    Maier, Thomas A.
    Summers, Michael S.
    Alvarez, Gonzalo
    Schulthess, Thomas C.
    PHYSICAL REVIEW B, 2009, 80 (19):
  • [29] Monte Carlo calculation of epithermal neutron resonance self-shielding factors in wires of different materials
    Gonçalves, IF
    Martinho, E
    Salgado, J
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (04) : 447 - 451
  • [30] Monte Carlo calculation of epithermal neutron resonance self-shielding factors in foils of different materials
    Gonçalves, IF
    Martinho, E
    Salgado, J
    APPLIED RADIATION AND ISOTOPES, 2002, 56 (06) : 945 - 951