Carbon dot/Co-MOF nanocoral mediated fluorescence-scattering ratiometric sensor for highly sensitive detection of alkaline phosphatase

被引:7
|
作者
Yao, Luxuan [1 ]
He, Shan [1 ]
Chen, Yiyu [1 ]
Lian, Huiting [1 ,3 ]
Liu, Bin [1 ,3 ,4 ]
Lai, Chengcai [2 ]
Wei, Xiaofeng [1 ,3 ,4 ]
机构
[1] Huaqiao Univ, Coll Mat Sci & Engn, Xiamen 361021, Peoples R China
[2] Beijing Inst Radiat Med, Dept Pharmaceut Sci, Beijing 100850, Peoples R China
[3] Huaqiao Univ, Key Lab Mol Designing & Green Convers, Xiamen 361021, Peoples R China
[4] Huaqiao Univ, Xiamen Key Lab Optoelect Mat & Adv Mfg, Xiamen 361021, Peoples R China
基金
中国国家自然科学基金;
关键词
Carbon dot; Metal organic framework; Second-order scattering; Fluorescence; Alkaline phosphatase; ASCORBIC-ACID; QUANTUM DOTS;
D O I
10.1016/j.talanta.2023.124863
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Abnormal expression of alkaline phosphatase (ALP) in serum has received considerable attention in health monitoring and disease diagnosis. However, conventional optical analysis based on a single signal must compromise background interference and limited sensitivity in trace analysis. As an alternative candidate, the ratiometric approach depends on the self-calibration of two independent signals in a single test to minimize interferences from the background for accurate identification. Here, a carbon dot/cobalt-metal organic framework nanocoral (CD/Co-MOF NC) mediated fluorescence-scattering ratiometric sensor has been developed for simple, stable, and highly sensitive detection of ALP. ALP-responsive phosphate production was used to coordinate cobalt ion and collapse the CD/Co-MOF NC, resulting in the recovery of fluorescence signal from dissociative CDs and the decrease of second-order scattering (SOS) signal from the cracked CD/Co-MOF NC. The ligand-substituted reaction and the optical ratiometric signal transduction provide a rapid and reliable chemical sensing mechanism. The ratiometric sensor effectively converted ALP into a ratio signal of fluorescencescattering dual emission throughout a wide linear concentration range of six orders of magnitude with a detection limit of 0.6 mU/L. In addition, self-calibration of fluorescence-scattering ratiometric method can reduce background interference and improve sensitivity in serum, approaching recoveries of ALP from 98.4% to 101.8%. Due to the above advantages, the CD/Co-MOF NC mediated fluorescence-scattering ratiometric sensor readily provides rapid and stable quantitative detection of ALP as a promising in vitro analytical method for clinical diagnostics.
引用
收藏
页数:7
相关论文
共 33 条
  • [21] Synergistic effect-mediated fluorescence switching of nitrogen-doped carbon dots for visual detection of alkaline phosphatase
    Ding, Shi Sen
    Li, Meng Xiao
    Xiang, Yu
    Tang, Jing
    Zhang, Qiang
    Huang, Min
    Zhao, Xiao Hui
    Wang, Jian
    Li, Chun Mei
    MICROCHEMICAL JOURNAL, 2022, 181
  • [22] A novel smartphone-mediated ratiometric fluorescence imprinting sensor based on boric acid-functionalized Eu-MOF for the detection of horseradish peroxidase
    Minghao Ma
    Wei Hu
    Shengdong Luo
    Fubin Pei
    Wu Lei
    Jiang Wang
    Zhaoyang Tong
    Bing Liu
    Bin Du
    Qingli Hao
    Xihui Mu
    Microchimica Acta, 2025, 192 (4)
  • [23] A Co-Doped Carbon Dot/Silver Nanoparticle Nanocomposite-Based Fluorescence Sensor for Metformin Hydrochloride Detection
    Thi-Hoa Le
    Kim, Ji-Hyeon
    Park, Sang-Joon
    NANOMATERIALS, 2022, 12 (08)
  • [24] A highly sensitive fluorescence probe for methyl parathion detection in vegetable and fruit samples based on N and S co-doped carbon dots
    Liu, Lingfei
    Qian, Minjie
    Sun, Huijuan
    Yang, Zhen-quan
    Xiao, Lixia
    Gong, Xiaojuan
    Hu, Qin
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2022, 107
  • [25] N, P Co-Doped Carbon Dots as Multifunctional Fluorescence Nano-Sensor for Sensitive and Selective Detection of Cr(VI) and Ascorbic Acid
    Tian, Yu-Lu
    Ji, Ya-Yun
    Zou, Xue
    Chen, Qiu-Meng
    Zhang, Sheng-Li
    Gong, Zheng-Jun
    JOURNAL OF ANALYSIS AND TESTING, 2022, 6 (03) : 335 - 345
  • [26] Hollow Cu/CoS2 Nanozyme with Defect-Induced Enzymatic Catalytic Sites and Binding Pockets for Highly Sensitive Fluorescence Detection of Alkaline Phosphatase
    Wang, Han
    Su, Ping
    Wei, Wenyu
    Song, Jiayi
    Yang, Yi
    SMALL, 2024, 20 (36)
  • [27] Highly selective and sensitive ratiometric detection of Hg2+ ions with NFS co-doped carbon dots: Real sample analysis, antibacterial properties, and cellular imaging applications
    Mohandoss, Sonaimuthu
    Velu, Kuppu Sakthi
    Wahab, Rizwan
    Ahmad, Naushad
    Palanisamy, Subramanian
    You, SangGuan
    Aslam, Mohammad
    Lee, Yong Rok
    Kim, Seong-Cheol
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2025, 326
  • [28] A turn-on fluorescent sensor for highly sensitive mercury(II) detection based on a carbon dot-labeled oligodeoxyribonucleotide and MnO2 nanosheets
    Li, Jingshuai
    Du, Bin
    Li, Yuewen
    Wang, Yaoguang
    Wu, Dan
    Wei, Qin
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (02) : 1228 - 1234
  • [29] A molecular imprinting-based turn-on Ratiometric fluorescence sensor for highly selective and sensitive detection of 2,4-dichlorophenoxyacetic acid (2,4-D)
    Wang, Xiaoyan
    Yu, Jialuo
    Wu, Xiaqing
    Fu, Junqing
    Kang, Qi
    Shen, Dazhong
    Li, Jinhua
    Chen, Lingxin
    BIOSENSORS & BIOELECTRONICS, 2016, 81 : 438 - 444
  • [30] A highly sensitive multifunctional Eu-MOF sensor with pentacarboxylate for fluorescence detecting acetone, Cu2+ and Cr2O72-, and electrochemical detection of TNP
    Gao, Loujun
    Jiao, Chunxia
    Chai, Hongmei
    Ren, Yixia
    Zhang, Gangqiang
    Yu, Hao
    Tang, Long
    JOURNAL OF SOLID STATE CHEMISTRY, 2020, 284