Carbon dot/Co-MOF nanocoral mediated fluorescence-scattering ratiometric sensor for highly sensitive detection of alkaline phosphatase

被引:7
|
作者
Yao, Luxuan [1 ]
He, Shan [1 ]
Chen, Yiyu [1 ]
Lian, Huiting [1 ,3 ]
Liu, Bin [1 ,3 ,4 ]
Lai, Chengcai [2 ]
Wei, Xiaofeng [1 ,3 ,4 ]
机构
[1] Huaqiao Univ, Coll Mat Sci & Engn, Xiamen 361021, Peoples R China
[2] Beijing Inst Radiat Med, Dept Pharmaceut Sci, Beijing 100850, Peoples R China
[3] Huaqiao Univ, Key Lab Mol Designing & Green Convers, Xiamen 361021, Peoples R China
[4] Huaqiao Univ, Xiamen Key Lab Optoelect Mat & Adv Mfg, Xiamen 361021, Peoples R China
基金
中国国家自然科学基金;
关键词
Carbon dot; Metal organic framework; Second-order scattering; Fluorescence; Alkaline phosphatase; ASCORBIC-ACID; QUANTUM DOTS;
D O I
10.1016/j.talanta.2023.124863
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Abnormal expression of alkaline phosphatase (ALP) in serum has received considerable attention in health monitoring and disease diagnosis. However, conventional optical analysis based on a single signal must compromise background interference and limited sensitivity in trace analysis. As an alternative candidate, the ratiometric approach depends on the self-calibration of two independent signals in a single test to minimize interferences from the background for accurate identification. Here, a carbon dot/cobalt-metal organic framework nanocoral (CD/Co-MOF NC) mediated fluorescence-scattering ratiometric sensor has been developed for simple, stable, and highly sensitive detection of ALP. ALP-responsive phosphate production was used to coordinate cobalt ion and collapse the CD/Co-MOF NC, resulting in the recovery of fluorescence signal from dissociative CDs and the decrease of second-order scattering (SOS) signal from the cracked CD/Co-MOF NC. The ligand-substituted reaction and the optical ratiometric signal transduction provide a rapid and reliable chemical sensing mechanism. The ratiometric sensor effectively converted ALP into a ratio signal of fluorescencescattering dual emission throughout a wide linear concentration range of six orders of magnitude with a detection limit of 0.6 mU/L. In addition, self-calibration of fluorescence-scattering ratiometric method can reduce background interference and improve sensitivity in serum, approaching recoveries of ALP from 98.4% to 101.8%. Due to the above advantages, the CD/Co-MOF NC mediated fluorescence-scattering ratiometric sensor readily provides rapid and stable quantitative detection of ALP as a promising in vitro analytical method for clinical diagnostics.
引用
收藏
页数:7
相关论文
共 33 条
  • [1] A ratiometric fluorescence-scattering sensor for rapid, sensitive and selective detection of doxycycline in animal foodstuffs
    Ding, Lu
    Cao, Yatian
    Li, Huihui
    Wang, Fuxiang
    Guo, Dong-Yu
    Yang, Weiting
    Pan, Qinhe
    FOOD CHEMISTRY, 2022, 373
  • [2] Physicochemically modulated fluorescence-scattering ratiometric sensor for selective and visual detection of levodopa
    Zhang, Jin Yuan
    Zhang, Ying
    Zou, Yu
    Xu, Ze Li Bo
    Zhang, Bo
    Ren, Wang
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 308
  • [3] Sensitive ratiometric fluorescence probe based on chitosan carbon dots and calcein for Alkaline phosphatase detection and bioimaging in cancer cells
    Mu, Xiaowei
    Jiang, Xue
    Zhang, Yu
    Liu, Xin
    Zhang, Siqi
    Wang, Wei
    Huang, Yibing
    Ma, Pinyi
    Song, Daqian
    ANALYTICA CHIMICA ACTA, 2021, 1188 (1188)
  • [4] A ratiometric lanthanide fluorescent probe for highly sensitive detection of alkaline phosphatase and arsenate
    Song, An-Min
    Tong, Yuan-Jun
    Liang, Ru-Ping
    Qiu, Jian-Ding
    MICROCHEMICAL JOURNAL, 2021, 164
  • [5] A ratiometric fluorescence sensor for highly selective and sensitive detection of mercuric ion
    Ma, Fang
    Sun, Mingtai
    Zhang, Kui
    Wang, Suhua
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 : 377 - 383
  • [6] Fluorescence-Scattering Dual-Signal Response of Carbon Dots@ZIF-90 for Phosphate Ratiometric Detection
    Wu, Zhihao
    Yang, Huan
    Pan, Shuang
    Liu, Hui
    Hu, Xiaoli
    ACS SENSORS, 2020, 5 (07): : 2211 - 2220
  • [7] Molecular imprinting ratiometric fluorescence sensor for highly selective and sensitive detection of phycocyanin
    Wang, Xiaoyan
    Yu, Jialuo
    Kang, Qi
    Shen, Dazhong
    Li, Jinhua
    Chen, Lingxin
    BIOSENSORS & BIOELECTRONICS, 2016, 77 : 624 - 630
  • [8] Hydrogel Optical Fiber Based Ratiometric Fluorescence Sensor for Highly Sensitive Ph Detection
    Zhao, Lishuai
    Li, Guoqiang
    Gan, Jiulin
    Yang, Zhongmin
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2021, 39 (20) : 6653 - 6659
  • [9] Nitrogen-doped Carbon Dots Mediated Fluorescent on-off Assay for Rapid and Highly Sensitive Pyrophosphate and Alkaline Phosphatase Detection
    Hu, Yalei
    Geng, Xin
    Zhang, Lin
    Huang, Zhongming
    Ge, Jia
    Li, Zhaohui
    SCIENTIFIC REPORTS, 2017, 7
  • [10] Controllable formation of polydopamine on carbon dots for ultrasensitive detection of alkaline phosphatase and ratiometric fluorescence immunoassay of benzocaine
    Lin, Shi-Qi
    Jia, Bao-Zhu
    Luo, Wei
    Wang, Hong
    Lei, Hong-Tao
    Zhang, Wen-Feng
    Xu, Zhen-Lin
    Luo, Lin
    FOOD CHEMISTRY, 2023, 426