Nowadays increasing energy demand and the current energy crisis in Europe highlighted the need for independent and cheap energy sources which can be produced at the place of use. A good example of this energy sources are the renewables, from which wind energy is one. Humanity is using wind energy since the beginning of the history, but electrical energy generation from the wind started at the end of the 19th Century. During the evolution of wind energy utilization, wind turbines are becoming more and more efficient. A special kind of these turbines are the non -conventional wind turbines which are aiming to be efficient in a special condition. One of these new turbine designs is the CO-DRWT (Counter -Rotating Dual Rotor Wind Turbine), where there are two rotors in one tower. During our research, we examined some layouts for a CO-DRWT. In these spatial arrangements, we were able to change the second rotor's axial and radial positions. Within two in axial and one diameter in the radial region, we were running CFD (Computational Fluid Dynamics) simulation to determine the interaction of the two turbines and for calculating the overall power coefficient (cp) for the two rotors. Meanwhile, in our analysis, we defined some spatial arrangements where the CO-DRWT's overall cp is less than the cp of a Single Rotor Wind Turbine (SRWT) from the same geometry. We also defined regions where the CO-DRWT's cp is higher than the SRWT's. With our geometry and with our simulation's boundary conditions we find the optimal place for operating a CO-DRWT is the R = 0D radial distance with A = 2.1D axial distance (where the D is the rotor's diameter) where the cp is 0.514, also the worst arrangement is the R = 0.35D with A = 1.25D where the cp = 0.354, while an SRWT's cp from the same geometry is 0.377. According to our simulations, the energy density and the power an optimized CO-DRWT are 1.363 times than an SRWT has.
引用
收藏
页码:203 / 222
页数:20
相关论文
共 26 条
  • [1] Alonso-Estebanez A., 2019, Recent Patents on Mechanical Engineering, V12, P158, DOI [10.2174/2212797612666190311154747, DOI 10.2174/2212797612666190311154747]
  • [2] A novel curtain design to enhance the aerodynamic performance of Invelox: A steady-RANS numerical simulation
    Anbarsooz, M.
    Amiri, M.
    Rashidi, I.
    [J]. ENERGY, 2019, 168 : 207 - 221
  • [3] [Anonymous], 2021, WIND TURBINES BIGGER
  • [4] Butler S, 2013, CONF CONTR FAULT-TOL, P389, DOI 10.1109/SysTol.2013.6693951
  • [5] ENERGY BALANCE OF A LOW ENERGY HOUSE
    Dziugaite-Tumeniene, Rasa
    Jankauskas, Vidmantas
    Motuziene, Violeta
    [J]. JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2012, 18 (03) : 369 - 377
  • [6] Efficient Axial Flow Turbine for Solar Chimney
    Elmagid, Walid M. A.
    Keppler, Istvan
    Molnar, Ildiko
    [J]. JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2020, 12 (03)
  • [7] Erturk E, 2018, INT J RENEW ENERGY R, V8, P1849
  • [8] Global Wind Energy Council, 2022, Global Wind Report 2022, P111
  • [9] Limits of the turbine efficiency for free fluid flow
    Gorban', AN
    Gorlov, AM
    Silantyev, VM
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2001, 123 (04): : 311 - 317
  • [10] COUNTER-ROTATING DUAL ROTOR WIND TURBINE LAYOUT OPTIMISATION
    Hetyei, Csaba
    Szlivka, Ferenc
    [J]. ACTA POLYTECHNICA, 2021, 61 (02) : 342 - 349