Structured Cs3Cu2I5 scintillation screen based on oxidized silicon micropore array template for high-resolution X-ray imaging

被引:1
作者
Teng, Yunxue [1 ]
Gu, Mu [1 ]
Sun, Zhixiang [1 ]
Liu, Xiaolin [1 ]
Liu, Bo [1 ]
Zhang, Juannan [1 ]
Huang, Shiming [1 ]
Ni, Chen [1 ]
机构
[1] Tongji Univ, Sch Phys Sci & Engn, Shanghai Key Lab Special Artificial Microstruct Ma, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Structured scintillation screen; Oxidized silicon micropore array template; High-resolution X-ray imaging; PERFORMANCE; FABRICATION; THICKNESS; DETECTOR; GUIDES; GROWTH; LAYER; FILMS;
D O I
10.1016/j.jlumin.2023.120116
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Improving the spatial resolution of X-ray imaging is one of the main directions of scintillation screen research. Herein, a structured Cs3Cu2I5 scintillation screen based on oxidized silicon micropore array template was developed. A feasible method was explored to solve the problems such as the preparation of oxidized silicon micropore array template with micron-period structure and the compact filling of Cs3Cu2I5 scintillator into the template. The X-ray imaging resolution using the structured Cs3Cu2I5 scintillation screen reaches 113 lp/mm attributing to the light guide and optical isolation of the template pore walls. The results of detective quantum efficiency, the X-ray imaging photographs of a micro-resolution plate and a small zebrafish show that the image quality using the structured screen is excellent. Meanwhile, the developed Cs3Cu2I5 scintillation screen exhibits good radiation resistance, which can keep the light output basically unchanged when the radiation dose is up to 43.2 Gy. The screen also exhibits good luminescence stability compared to Cs3Cu2I5 itself due to the protection of the template. These indicate that the structured Cs3Cu2I5 scintillation screen has a good application prospect in high-resolution X-ray imaging.
引用
收藏
页数:8
相关论文
共 42 条
  • [1] Hydrothermal growth of vertically aligned ZnO nanorods as potential scintillator materials for radiation detectors
    Angub, Maria Cecilia M.
    Vergara, Christopher Jude T.
    Husay, Horace Andrew F.
    Salvador, Arnel A.
    Empizo, Melvin John F.
    Kawano, Keisuke
    Minami, Yuki
    Shimizu, Toshihiko
    Sarukura, Nobuhiko
    Somintac, Armando S.
    [J]. JOURNAL OF LUMINESCENCE, 2018, 203 : 427 - 435
  • [2] Performance of scintillating waveguides for CCD-based X-ray detectors
    Badel, X
    Norlin, B
    Kleimann, P
    Williams, L
    Moody, SJ
    Tyrrell, GC
    Fröjdh, C
    Linnros, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 3 - 8
  • [3] Metallized and oxidized silicon macropore arrays filled with a scintillator for CCD-based X-ray imaging detectors
    Badel, X
    Linnros, J
    Kleimann, P
    Norlin, B
    Koskiahde, E
    Valpas, K
    Nenonen, S
    Petersson, CS
    Fröjdh, C
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 1001 - 1005
  • [4] Improvement of an X-ray imaging detector based on a scintillating guides screen
    Badel, X
    Galeckas, A
    Linnros, J
    Kleimann, P
    Fröjdh, C
    Petersson, CS
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 487 (1-2) : 129 - 135
  • [5] Chaiphaksa W., 2014, Advanced Materials Research, V979, P285, DOI 10.4028/www.scientific.net/AMR.979.285
  • [6] Spatial resolution and light output of pixelated CsI(TI) scintillation screen based on oxidized silicon micropore array template
    Chen, H.
    Gu, M.
    Liu, X.
    Huang, S.
    Liu, B.
    Zhang, J.
    [J]. JOURNAL OF INSTRUMENTATION, 2018, 13
  • [7] Influence of silicon wall thickness on the performance of structured CsI(Tl) scintillation screen based on oxidized silicon micropore array template in X-ray imaging
    Chen, Hui
    Gu, Mu
    Sun, Zhixiang
    Liu, Xiaolin
    Liu, Bo
    Zhang, Juannan
    Huang, Shiming
    Ni, Chen
    [J]. OPTICS EXPRESS, 2019, 27 (10) : 14871 - 14880
  • [8] Simulated performances of pixelated CsI(Tl) scintillation screens with different micro-column shapes and array structures in X-ray imaging
    Chen, Hui
    Gu, Mu
    Liu, Xiaolin
    Zhang, Juannan
    Liu, Bo
    Huang, Shiming
    Ni, Chen
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [9] Influence of preparation process on the transparency of CsI microcolumns in the structured CsI scintillation screen based on oxidized silicon micropore array template
    Chen, Ken
    Gu, Mu
    Sun, Zhixiang
    Liu, Xiaolin
    Liu, Bo
    Huang, Shiming
    Zhang, Juannan
    Ni, Chen
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 991
  • [10] Zero-Dimensional Cs3Cu2I5Perovskite Single Crystal as Sensitive X-Ray and γ-Ray Scintillator
    Cheng, Shuangliang
    Beitlerova, Alena
    Kucerkova, Romana
    Nikl, Martin
    Ren, Guohao
    Wu, Yuntao
    [J]. PHYSICA STATUS SOLIDI-RAPID RESEARCH LETTERS, 2020, 14 (11):