The pEGASUS-HPC stent system for stent-assisted coiling of cerebral aneurysms: a multicenter case series

被引:4
作者
Lobsien, Donald [1 ]
Holtmannspoetter, Markus [2 ]
Eff, Florian [2 ]
Berlis, Ansgar [3 ]
Maurer, Christoph Johannes [3 ]
Behme, Daniel [4 ]
Diamandis, Elie [4 ]
Gawlitza, Matthias [5 ]
Fiorella, David [6 ]
Princiotta, Ciro [7 ]
Cirillo, Luigi [7 ,8 ]
Dall'Olio, Massimo [7 ]
Keston, Peter [9 ]
Klisch, Joachim [1 ]
Nania, Alberto [9 ]
机构
[1] HELIOS Klinikum Erfurt, Clin Neuroradiol, D-99089 Erfurt, Germany
[2] Nuremberg Hosp Campus South, Intervent & Diagnost Neuroradiol, Nurnberg, Germany
[3] Univ Hosp Augsburg, Dept Diagnost & Intervent Radiol & Neuroradiol, Augsburg, Germany
[4] Univ Hosp Magdeburg, Dept Neuroradiol, Magdeburg, Germany
[5] Univ Hosp Leipzig, Inst Neuroradiol, Leipzig, Germany
[6] SUNY Stony Brook, Dept Neurosurg, Stony Brook, NY USA
[7] IRCCS Inst Neurol Sci Bologna, Neuroradiol Dept, Bologna, Italy
[8] Univ Bologna, Dept Expt Diagnost & Specialty Med, Bologna, Italy
[9] NHS Lothian, Dept Clin Neurosci, Edinburgh, Scotland
关键词
Aneurysm; Coil; Stent; INTRACRANIAL ANEURYSMS;
D O I
10.1136/jnis-2023-021074
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
BackgroundStent-assisted coiling (SAC) is a well-established method for treatment of wide-necked intracranial aneurysms. In this multicenter, retrospective case series we evaluated SAC with a new low-profile, laser-cut stent with an antithrombogenic hydrophilic polymer coating (pEGASUS-HPC) for the treatment of intracranial aneurysms.MethodsPatients treated with pEGASUS-HPC SAC for one or more intracranial aneurysms were retrospectively included. Clinical, imaging, and procedural parameters as well as clinical and imaging follow-up data were recorded.ResultsWe treated 53 aneurysms in 52 patients in six neurovascular centers between August 2021 and November 2022. Thirty-seven patients (69.8%) were female. Mean age was 57 (+/- 11.7) years. Twenty-nine patients were treated electively, 23 in the acute phase (22 with aneurysmal subarachnoid hemorrhage (SAH), and 1 with a partially thrombosed aneurysm causing ischemic events). One intraprocedural thromboembolic event and three postprocedural ischemic complications occurred in two (8.7 %) of the SAH patients and in one of the elective patients (3.45%). Overall aneurysm occlusion was Raymond Roy (RR) I in 36 (69.2%), RR II in 9, and RR III in 9 cases. Follow-up imaging was available for 23 patients after an average of 147.7 (+/- 59.6) days demonstrating RR I occlusion in 22 (95.5%) and RR II in 1 patient.ConclusionSAC with the pEGASUS-HPC stent system demonstrates rates of periprocedural safety and effectiveness that are comparable with previously reported series for stent-assisted coil embolization.
引用
收藏
页码:e152 / e158
页数:7
相关论文
共 18 条
[1]   Phenox HPC and Phenox flow modulation devices for the endovascular treatment of intracranial aneurysms: a systematic review and meta-analysis [J].
Bilgin, Cem ;
Senol, Yigit Can ;
Kobeissi, Hassan ;
Orscelik, Atakan ;
Ghozy, Sherief ;
Oliver, Alexander A. ;
Kadirvel, Ramanathan ;
Brinjikji, Waleed ;
Kallmes, David F. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024, 16 (07) :706-714
[2]   Stent-Assisted Coiling in the Treatment of Unruptured Intracranial Aneurysms: A Randomized Clinical Trial [J].
Boisseau, W. ;
Darsaut, T. E. ;
Fahed, R. ;
Drake, B. ;
Lesiuk, H. ;
Rempel, J. L. ;
Gentric, J. -c. ;
Ognard, J. ;
Nico, L. ;
Iancu, D. ;
Roy, D. ;
Weill, A. ;
Chagnon, M. ;
Zehr, J. ;
Lavoie, P. ;
Nguyen, T. N. ;
Raymond, J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2023, 44 (04) :381-389
[3]   Safety of stent-assisted coiling for the treatment of wide-necked ruptured aneurysm: A systematic literature review and meta-analysis of prevalence [J].
Bsat, Shadi ;
Bsat, Ayman ;
Tamim, Hani ;
Chanbour, Hani ;
Alomari, Safwan Omar ;
El Houshiemy, Mohamad Nabih ;
Moussalem, Charbel ;
Omeis, Ibrahim .
INTERVENTIONAL NEURORADIOLOGY, 2020, 26 (05) :547-556
[4]   A Systematic Literature Review and Meta-Analysis of the Treatment of Ruptured Intracranial Aneurysms with Hydrophilic Polymer and Phosphorylcholine-Coated Flow Diverters Under Single Antiplatelet Therapy [J].
Gawlitza, Matthias ;
Klisch, Joachim ;
Kaiser, Daniel P. O. ;
Linn, Jennifer ;
Pierot, Laurent ;
Lobsien, Donald .
WORLD NEUROSURGERY, 2023, 170 :E791-E800
[5]   Use of a p64 MW Flow Diverter with Hydrophilic Polymer Coating (HPC) and Prasugrel Single Antiplatelet Therapy for the Treatment of Unruptured Anterior Circulation Aneurysms: Safety Data and Short-term Occlusion Rates [J].
Hellstern, V ;
Perez, M. Aguilar ;
Henkes, E. ;
Donauer, E. ;
Wendl, C. ;
Baezner, H. ;
Ganslandt, O. ;
Henkes, H. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 45 (09) :1364-1374
[6]   Anti-thrombogenic coatings for devices in neurointerventional surgery: Case report and review of the literature [J].
Henkes, Hans ;
Bhogal, Pervinder ;
Perez, Marta Aguilar ;
Lenz-Habijan, Tim ;
Bannewitz, Catrin ;
Peters, Marcus ;
Sengstock, Christina ;
Ganslandt, Oliver ;
Lylyk, Pedro ;
Monstadt, Hermann .
INTERVENTIONAL NEURORADIOLOGY, 2019, 25 (06) :619-627
[7]   Intravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery - Case report and review of the literature [J].
Higashida, RT ;
Smith, W ;
Gress, D ;
Urwin, R ;
Dowd, CF ;
Balousek, PA ;
Halbach, VV .
JOURNAL OF NEUROSURGERY, 1997, 87 (06) :944-949
[8]   Hydrophilic Stent Coating Inhibits Platelet Adhesion on Stent Surfaces: Initial Results In Vitro [J].
Lenz-Habijan, Tim ;
Bhogal, P. ;
Peters, Marcus ;
Bufe, Albrecht ;
Martinez Moreno, Rosa ;
Bannewitz, Catrin ;
Monstadt, Hermann ;
Henkes, Hans .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 41 (11) :1779-1785
[9]   Treatment of broad-based intracranial aneurysms with the LVIS EVO stent: a retrospective observational study at two centers with short- and medium-term follow-up [J].
Maurer, Christoph J. ;
Berlis, Ansgar ;
Maus, Volker ;
Behrens, Lars ;
Weber, Werner ;
Fischer, Sebastian .
SCIENTIFIC REPORTS, 2023, 13 (01)
[10]   Long-term results of wide-necked intracranial bifurcation aneurysms treated with stent-assisted coiling using low-profile acandis acclino stents [J].
Melber, Katharina ;
Boxberg, Frederik W. ;
Schlunz-Hendann, Martin ;
Brassel, Friedhelm ;
Grieb, Dominik F. J. .
INTERVENTIONAL NEURORADIOLOGY, 2022, :623-630