Speech production real-time MRI at 0.55 T

被引:4
作者
Lim, Yongwan [1 ]
Kumar, Prakash [1 ,2 ]
Nayak, Krishna S. [1 ]
机构
[1] Univ Southern Calif, Viterbi Sch Engn, Ming Hsieh Dept Elect & Comp Engn, Los Angeles, CA USA
[2] Univ Southern Calif, Viterbi Sch Engn, Ming Hsieh Dept Elect & Comp Engn, 3740 McClintock Ave,EEB 400, Los Angeles, CA 90089 USA
基金
美国国家科学基金会;
关键词
0.55; T; real-time MRI; speech production; spiral; susceptibility artifact; IMAGES; RECONSTRUCTION; FEASIBILITY; ACQUISITION; RESOLUTION; SYSTEM; FLASH;
D O I
10.1002/mrm.29843
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate speech-production real-time MRI (RT-MRI) using a contemporary 0.55T system, and to identify opportunities for improved performance compared with conventional field strengths.Methods: Experiments were performed on healthy adult volunteers using a 0.55T MRI system with high-performance gradients and a custom 8-channel upper airway coil. Imaging was performed using spiral-based balanced SSFP and gradient-recalled echo (GRE) pulse sequences using a temporal finite-difference constrained reconstruction. Speech-production RT-MRI was performed with three spiral readout durations (8.90, 5.58, and 3.48 ms) to determine trade-offs with respect to articulator contrast, blurring, banding artifacts, and overall image quality.Results: Both spiral GRE and bSSFP captured tongue boundary dynamics during rapid consonant-vowel syllables. Although bSSFP provided substantially higher SNR in all vocal tract articulators than GRE, it suffered from banding artifacts at TR > 10.9 ms. Spiral bSSFP with the shortest readout duration (3.48 ms, TR = 5.30 ms) had the best image quality, with a 1.54-times boost in SNR compared with an equivalent GRE sequence. Longer readout durations led to increased SNR efficiency and blurring in both bSSFP and GRE.Conclusion: High-performance 0.55T MRI systems can be used for speech-production RT-MRI. Spiral bSSFP can be used without suffering from banding artifacts in vocal tract articulators, provide better SNR efficiency, and have better image quality than what is typically achieved at 1.5 T or 3 T.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 50 条
[31]   Towards Speech Classification from Acoustic and Vocal Tract data in Real-time MRI [J].
Yue, Yaoyao ;
Proctor, Michael ;
Zhou, Luping ;
Gupta, Rijul ;
Piyadasa, Tharinda ;
Gully, Amelia ;
Ballard, Kirrie ;
Tin, Craig .
INTERSPEECH 2024, 2024, :1345-1349
[32]   Real-time speech MRI datasets with corresponding articulator ground-truth segmentations [J].
Ruthven, Matthieu ;
Peplinski, Agnieszka M. ;
Adams, David M. ;
King, Andrew P. ;
Miquel, Marc Eric .
SCIENTIFIC DATA, 2023, 10 (01)
[33]   Assessment of esophageal motility disorders by real-time MRI [J].
Biggemann, Lorenz ;
Uhlig, Johannes ;
Gliem, Nina ;
Al-Bourini, Omar ;
Wedi, Edris ;
Ellenrieder, Volker ;
Ghadimi, Michael ;
Uecker, Martin ;
Frahm, Jens ;
Lotz, Joachim ;
Hosseini, Ali Seif Amir ;
Streit, Ulrike .
EUROPEAN JOURNAL OF RADIOLOGY, 2020, 132
[34]   Aggregated Motion Estimation for Real-Time MRI Reconstruction [J].
Li, Housen ;
Haltmeier, Markus ;
Zhang, Shuo ;
Frahm, Jens ;
Munk, Axel .
MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) :1039-1048
[35]   Aliasing artifact reduction in spiral real-time MRI [J].
Tian, Ye ;
Lim, Yongwan ;
Zhao, Ziwei ;
Byrd, Dani ;
Narayanan, Shrikanth ;
Nayak, Krishna S. .
MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (02) :916-925
[36]   Real-time MRI of swallowing: intraoral pressure reduction supports larynx elevation [J].
Olthoff, Arno ;
Joseph, Arun A. ;
Weidenmueller, Matthias ;
Riley, Blake ;
Frahm, Jens .
NMR IN BIOMEDICINE, 2016, 29 (11) :1618-1623
[37]   Navigators for motion detection during real-time MRI-guided radiotherapy [J].
Stam, Mette K. ;
Crijns, Sjoerd P. M. ;
Zonnenberg, Bernard A. ;
Barendrecht, Maurits M. ;
van Vulpen, Marco ;
Lagendijk, Jan J. W. ;
Raaymakers, Bas W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (21) :6797-6805
[38]   Preprocessing for acoustic-to-articulatory inversion using real-time MRI movies of Japanese speech [J].
Oura, Anna ;
Kikuchi, Hideaki ;
Kobayashi, Tetsunori .
INTERSPEECH 2024, 2024, :1550-1554
[39]   Extraction of speech organ contours from ultrasound and real-time MRI data using DeepLabCut [J].
Sun, Jing ;
Kitamura, Tatsuya ;
Hayashi, Ryoko .
ACOUSTICAL SCIENCE AND TECHNOLOGY, 2025, 46 (04) :338-344
[40]   Real-Time Flow MRI of the Aorta at a Resolution of 40 msec [J].
Joseph, Arun ;
Kowallick, Johannes T. ;
Merboldt, Klaus-Dietmar ;
Voit, Dirk ;
Schaetz, Sebastian ;
Zhang, Shuo ;
Sohns, Jan M. ;
Lotz, Joachim ;
Frahm, Jens .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (01) :206-213