Speech production real-time MRI at 0.55 T

被引:3
|
作者
Lim, Yongwan [1 ]
Kumar, Prakash [1 ,2 ]
Nayak, Krishna S. [1 ]
机构
[1] Univ Southern Calif, Viterbi Sch Engn, Ming Hsieh Dept Elect & Comp Engn, Los Angeles, CA USA
[2] Univ Southern Calif, Viterbi Sch Engn, Ming Hsieh Dept Elect & Comp Engn, 3740 McClintock Ave,EEB 400, Los Angeles, CA 90089 USA
基金
美国国家科学基金会;
关键词
0.55; T; real-time MRI; speech production; spiral; susceptibility artifact; IMAGES; RECONSTRUCTION; FEASIBILITY; ACQUISITION; RESOLUTION; SYSTEM; FLASH;
D O I
10.1002/mrm.29843
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate speech-production real-time MRI (RT-MRI) using a contemporary 0.55T system, and to identify opportunities for improved performance compared with conventional field strengths.Methods: Experiments were performed on healthy adult volunteers using a 0.55T MRI system with high-performance gradients and a custom 8-channel upper airway coil. Imaging was performed using spiral-based balanced SSFP and gradient-recalled echo (GRE) pulse sequences using a temporal finite-difference constrained reconstruction. Speech-production RT-MRI was performed with three spiral readout durations (8.90, 5.58, and 3.48 ms) to determine trade-offs with respect to articulator contrast, blurring, banding artifacts, and overall image quality.Results: Both spiral GRE and bSSFP captured tongue boundary dynamics during rapid consonant-vowel syllables. Although bSSFP provided substantially higher SNR in all vocal tract articulators than GRE, it suffered from banding artifacts at TR > 10.9 ms. Spiral bSSFP with the shortest readout duration (3.48 ms, TR = 5.30 ms) had the best image quality, with a 1.54-times boost in SNR compared with an equivalent GRE sequence. Longer readout durations led to increased SNR efficiency and blurring in both bSSFP and GRE.Conclusion: High-performance 0.55T MRI systems can be used for speech-production RT-MRI. Spiral bSSFP can be used without suffering from banding artifacts in vocal tract articulators, provide better SNR efficiency, and have better image quality than what is typically achieved at 1.5 T or 3 T.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 50 条
  • [1] Analysis of speech production real-time MRI
    Ramanarayanan, Vikram
    Tilsen, Sam
    Proctor, Michael
    Toger, Johannes
    Goldstein, Louis
    Nayak, Krishna S.
    Narayanan, Shrikanth
    COMPUTER SPEECH AND LANGUAGE, 2018, 52 : 1 - 22
  • [2] Real-time MRI of the moving wrist at 0.55 tesla
    Chaudhari, Abhijit J.
    Lim, Yongwan
    Cui, Sophia X.
    Bayne, Christopher O.
    Szabo, Robert M.
    Boutin, Robert D.
    Nayak, Krishna S.
    BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1151):
  • [3] Real-time MRI evaluation of speech production following glossectomy
    Mady, K
    Beer, A
    Sader, R
    Hoole, P
    ORAL ONCOLOGY, 2005, 1 (01) : 201 - 201
  • [4] Simultaneous multi-slice cardiac real-time MRI at 0.55T
    Yagiz, Ecrin
    Garg, Parveen
    Cen, Steven Y.
    Nayak, Krishna S.
    Tian, Ye
    MAGNETIC RESONANCE IN MEDICINE, 2024,
  • [5] Simultaneous multi-slice cardiac real-time MRI at 0.55T
    Yagiz, Ecrin
    Garg, Parveen
    Cen, Steven Y.
    Nayak, Krishna S.
    Tian, Ye
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (04) : 1723 - 1732
  • [6] Recommendations for real-time speech MRI
    Lingala, Sajan Goud
    Sutton, Brad P.
    Miquel, Marc E.
    Nayak, Krishna S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (01) : 28 - 44
  • [7] Real-time fetal brain and placental T2*mapping at 0.55T MRI
    Verdera, Jordina Aviles
    Silva, Sara Neves
    Payette, Kelly M.
    Tomi-Tricot, Raphael
    Hall, Megan
    Story, Lisa
    Malik, Shaihan J.
    Hajnal, Joseph V.
    Rutherford, Mary A.
    Hutter, Jana
    MAGNETIC RESONANCE IN MEDICINE, 2025,
  • [8] Improved 3D real-time MRI of speech production
    Zhao, Ziwei
    Lim, Yongwan
    Byrd, Dani
    Narayanan, Shrikanth
    Nayak, Krishna S.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (06) : 3182 - 3195
  • [9] Real-time MRI and articulatory coordination in speech
    Demolin, D
    Hassid, S
    Metens, T
    Soquet, A
    COMPTES RENDUS BIOLOGIES, 2002, 325 (04) : 547 - 556
  • [10] Intermittently tagged real-time MRI reveals internal tongue motion during speech production
    Chen, Weiyi
    Byrd, Dani
    Narayanan, Shrikanth
    Nayak, Krishna S.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (02) : 600 - 613