Electrochemical sensing of methotrexate in the presence of folic acid using PAMAM dendrimer-functionalized multiwalled carbon nanotube-modified electrode

被引:4
作者
Nejad, Fariba Garkani [1 ]
Beitollahi, Hadi [2 ]
Sheikhshoaie, Iran [1 ]
机构
[1] Shahid Bahonar Univ Kerman, Fac Sci, Dept Chem, Kerman, Iran
[2] Grad Univ Adv Technol, Inst Sci & High Technol & Environm Sci, Environm Dept, Kerman, Iran
关键词
VOLTAMMETRIC DETERMINATION; PASTE ELECTRODE; GRAPHENE OXIDE; LIQUID; SENSOR; BLOOD; CHROMATOGRAPHY; NANOCOMPOSITE; ACETAMINOPHEN; POLYMERS;
D O I
10.1039/d2ay02093a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This works presents a novel electrochemical sensor based on the third-generation poly(amidoamine) dendrimer (G3 PAMAM)-functionalized multiwalled carbon nanotube (MWCNT)-modified screen-printed graphite electrode (SPGE) for the simple and sensitive detection of methotrexate (MTX). The carboxylated MWCNTs were covalently functionalized with amino groups of G3 PAMAM and characterized using different techniques. The sensing ability of the designed nanosensor (MWCNTs-PAMAM/SPGE) was tested using differential pulse voltammetry (DPV), chronoamperometry (CHA), linear sweep voltammetry (LSV), and cyclic voltammetry (CV). To investigate the electrocatalytic activity of PAMAM-functionalized MWCNTs, a comparative electrochemical analysis was carried out and it was determined that PAMAM-functionalized MWCNT-modified SPGE showed good electrocatalytic performance for MTX oxidation compared to the unmodified SPGE. The MWCNT-PAMAM/SPGE lead to a reduced overpotential of MTX oxidation of about 300 mV and enhanced current of about 9 & mu;A of the unmodified SPGE. Experiments were performed for the quantitative determination of MTX using the DPV technique. The response peak current linearly related against MTX concentration in the ranges from 0.01 to 110.0 & mu;M and a limit of detection (LOD) equal to 0.003 & mu;M. Also, MWCNT-PAMAM/SPGE exhibits good catalytic ability toward MTX determination in the presence of folic acid (FA), and the separation of their oxidation peaks (peak potential difference = 320 mV) simultaneously detected the above compounds. To prove the applicability of the MWCNT-PAMAM/SPGE sensor, the concentrations of MTX and FA in pharmaceutical products and biological samples were determined. The calculated recoveries were close to 100%, which indicates that the method might be assumed to be accurate.
引用
收藏
页码:3196 / 3205
页数:10
相关论文
共 86 条
[1]   Simultaneous Extraction and Preconcentration of Benzene, Toluene, Ethylbenzene and Xylenes from Aqueous Solutions Using Magnetite-Graphene Oxide Composites [J].
Abadi, Mohammad Ameri Akhtiar ;
Masrournia, Mahboubeh ;
Abedi, Mohamad Reza .
CHEMICAL METHODOLOGIES, 2021, 5 (01) :11-20
[2]   HIGH-DOSE METHOTREXATE - A CRITICAL REAPPRAISAL [J].
ACKLAND, SP ;
SCHILSKY, RL .
JOURNAL OF CLINICAL ONCOLOGY, 1987, 5 (12) :2017-2031
[3]   Simultaneous determination of doxorubicin and dasatinib as two breast anticancer drugs uses an amplified sensor with ionic liquid and ZnO nanoparticle [J].
Alavi-Tabari, Seyed A. R. ;
Khalilzadeh, Mohammad A. ;
Karimi-Maleh, Hassan .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 811 :84-88
[4]   Electrical Conductivity, Thermal Behavior, and Seebeck Coefficient of Conductive Films for Printed Thermoelectric Energy Harvesting Systems [J].
Ankireddy, Krishnamraju ;
Menon, Akanksha K. ;
Iezzi, Brian ;
Yee, Shannon K. ;
Losego, Mark D. ;
Jur, Jesse S. .
JOURNAL OF ELECTRONIC MATERIALS, 2016, 45 (11) :5561-5569
[5]   Design and Construction of a Novel and an Efficient Potentiometric Sensor for Determination of Sodium Ion in Urban Water Samples [J].
Ariavand, Shiva ;
Ebrahimi, Mahmoud ;
Foladi, Ebrahim .
CHEMICAL METHODOLOGIES, 2022, 6 (11) :886-904
[6]   Glassy carbon electrode modified with 3D graphene-carbon nanotube network for sensitive electrochemical determination of methotrexate [J].
Asadian, Elham ;
Shahrokhian, Saeed ;
Zad, Azam Iraji ;
Ghorbani-Bidkorbeh, Fatemeh .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 239 :617-627
[7]  
Azar Negar Taghavi Pourian, 2013, HACETTEPE JOURNAL OF BIOLOGY AND CHEMISTRY, V41, P289
[8]   Simultaneous determination of low levels of methotrexate and cyclophosphamide in human urine by micro liquid chromatography/electrospray ionization tandem mass spectrometry [J].
Barbieri, A ;
Sabatini, L ;
Indiveri, P ;
Bonfiglioli, R ;
Lodi, V ;
Violante, FS .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (12) :1889-1893
[9]  
Bard A.J., 1980, Electrochemical methods: fundamentals and applications, V2
[10]   Screen-printed electrodes for environmental monitoring of heavy metal ions: a review [J].
Barton, John ;
Gonzalez Garcia, Maria Begona ;
Hernandez Santos, David ;
Fanjul-Bolado, Pablo ;
Ribotti, Alberto ;
McCaul, Margaret ;
Diamond, Dermot ;
Magni, Paolo .
MICROCHIMICA ACTA, 2016, 183 (02) :503-517