Environmentally Resilient Microfluidic Point-of-Care Immunoassay Enables Rapid Diagnosis of Talaromycosis

被引:1
作者
Kinnamon, David S. [1 ]
Heggestad, Jacob T. [1 ]
Liu, Jason [1 ]
Nguyen, Thu [2 ]
Ly, Vo [3 ,4 ]
Hucknall, Angus M. [1 ]
Fontes, Cassio M. [1 ]
Britton, Rhett J. [1 ]
Cai, Jian-Piao [5 ]
Chan, Jasper Fuk-Woo [5 ,6 ]
Yuen, Kwok-Yung [5 ,6 ]
Le, Thuy [2 ]
Chilkoti, Ashutosh [1 ]
机构
[1] Duke Univ, Pratt Sch Engn, Dept Biomed Engn, Durham, NC 27708 USA
[2] Duke Univ, Sch Med, Div Infect Dis & Int Hlth, Durham, NC 27708 USA
[3] Hosp Trop Dis, Ho Chi Minh City 73009, Vietnam
[4] Univ Med & Pharm Ho Chi Minh City, Ho Chi Minh City 72714, Vietnam
[5] Univ Hong Kong, Li Ka Shing Fac Med, Carol Yu Ctr Infect, Sch Clin Med,Dept Microbiol,State Key Lab Emerging, Hong Kong, Peoples R China
[6] Hainan Med Univ, Hainan Med Univ Univ Hong Kong Joint Lab Trop Infe, Haikou 571101, Hainan, Peoples R China
关键词
microfluidics; biosensor; infectious disease; immunoassay; point-of-care test; diagnostics; SPECIFICITY; SENSITIVITY; BRUSHES; ASSAY; SERUM;
D O I
10.1021/acssensors.3c00209
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Point-of-care tests (POCTs) are increasingly being used in field settings, particularly outdoors. The performance of current POCTs-most commonly the lateral flow immunoassay-can be adversely affected by ambient temperature and humidity. We developed a self-contained immunoassay platform-the D4 POCT-that can be conducted at the POC by integrating all reagents in a capillary-driven passive microfluidic cassette that minimizes user intervention. The assay can be imaged and analyzed on a portable fluorescence reader-the D4Scope-and provide quantitative outputs. Here, we systematically investigated the resilience of our D4 POCT to varied temperature and humidity and to physiologically diverse human whole blood samples that span a wide range of physiological hematocrit (30-65%). For all conditions, we showed that the platform maintained high sensitivity (0.05-0.41 ng/mL limits of detection). The platform also demonstrated good accuracy in reporting true analyte concentration across environmental extremes when compared to the manually operated format of the same test to detect a model analyte-ovalbumin. Additionally, we engineered an improved version of the microfluidic cassette that improved the ease-of-use of the device and shortened the time-to-result. We implemented this new cassette to create a rapid diagnostic test to detect talaromycosis infection in patients with advanced HIV disease at the POC, demonstrating comparable sensitivity and specificity to the laboratory test for the disease.
引用
收藏
页码:2228 / 2236
页数:9
相关论文
共 32 条
  • [11] Effects of Talaromyces marneffei infection on mortality of HIV/AIDS patients in southern China: a retrospective cohort study
    Jiang, J.
    Meng, S.
    Huang, S.
    Ruan, Y.
    Lu, X.
    Li, J. Z.
    Wu, N.
    Huang, J.
    Xie, Z.
    Liang, B.
    Deng, J.
    Zhou, B.
    Chen, X.
    Ning, C.
    Liao, Y.
    Wei, W.
    Lai, J.
    Ye, L.
    Wu, F.
    Liang, H.
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2019, 25 (02) : 233 - 241
  • [12] Joh DY, 2021, NPJ BREAST CANCER, V7, DOI [10.1038/s41523-021-00335-4, 10.1038/s41523-021-00290-0]
  • [13] Inkjet-printed point-of-care immunoassay on a nanoscale polymer brush enables subpicomolar detection of analytes in blood
    Joh, Daniel Y.
    Hucknall, Angus M.
    Wei, Qingshan
    Mason, Kelly A.
    Lund, Margaret L.
    Fontes, Cassio M.
    Hill, Ryan T.
    Blair, Rebecca
    Zimmers, Zackary
    Achar, Rohan K.
    Tseng, Derek
    Gordan, Raluca
    Freemark, Michael
    Ozcan, Aydogan
    Chilkoti, Ashutosh
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2017, 114 (34) : E7054 - E7062
  • [14] Poly(oligo(ethylene glycol) methyl ether methacrylate) Brushes on High-K Metal Oxide Dielectric Surfaces for Bioelectrical Environments
    Joh, Daniel Y.
    McGuire, Felicia
    Abedini-Nassab, Roozbeh
    Andrews, Joseph B.
    Achar, Rohan K.
    Zimmers, Zackary
    Mozhdehi, Darush
    Blair, Rebecca
    Albarghouthi, Faris
    Oles, William
    Richter, Jacob
    Fontes, Cassio M.
    Hucknall, Angus M.
    Yellen, Benjamin B.
    Franklin, Aaron D.
    Chilkoti, Ashutosh
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (06) : 5522 - 5529
  • [15] Clinical and laboratory characteristics of penicilliosis marneffei among patients with and without HIV infection in Northern Thailand: a retrospective study
    Kawila, Rathakarn
    Chaiwarith, Romanee
    Supparatpinyo, Khuanchai
    [J]. BMC INFECTIOUS DISEASES, 2013, 13
  • [16] KILSHAW PJ, 1986, CLIN EXP IMMUNOL, V66, P481
  • [17] Fungal infections in HIV/AIDS
    Limper, Andrew H.
    Adenis, Antoine
    Le, Thuy
    Harrison, Thomas S.
    [J]. LANCET INFECTIOUS DISEASES, 2017, 17 (11) : E334 - E343
  • [18] IMPROVED ELISA CONDITIONS FOR DETECTION OF PLANT-VIRUSES
    MCLAUGHLIN, MR
    BARNETT, OW
    BURROWS, PM
    BAUM, RH
    [J]. JOURNAL OF VIROLOGICAL METHODS, 1981, 3 (01) : 13 - 25
  • [19] Millipore Sigma, ELISA PROC
  • [20] Capillary microfluidics in microchannels: from microfluidic networks to capillaric circuits
    Olanrewaju, Ayokunle
    Beaugrand, Maiwenn
    Yafia, Mohamed
    Juncker, David
    [J]. LAB ON A CHIP, 2018, 18 (16) : 2323 - 2347