Environmentally Resilient Microfluidic Point-of-Care Immunoassay Enables Rapid Diagnosis of Talaromycosis

被引:1
作者
Kinnamon, David S. [1 ]
Heggestad, Jacob T. [1 ]
Liu, Jason [1 ]
Nguyen, Thu [2 ]
Ly, Vo [3 ,4 ]
Hucknall, Angus M. [1 ]
Fontes, Cassio M. [1 ]
Britton, Rhett J. [1 ]
Cai, Jian-Piao [5 ]
Chan, Jasper Fuk-Woo [5 ,6 ]
Yuen, Kwok-Yung [5 ,6 ]
Le, Thuy [2 ]
Chilkoti, Ashutosh [1 ]
机构
[1] Duke Univ, Pratt Sch Engn, Dept Biomed Engn, Durham, NC 27708 USA
[2] Duke Univ, Sch Med, Div Infect Dis & Int Hlth, Durham, NC 27708 USA
[3] Hosp Trop Dis, Ho Chi Minh City 73009, Vietnam
[4] Univ Med & Pharm Ho Chi Minh City, Ho Chi Minh City 72714, Vietnam
[5] Univ Hong Kong, Li Ka Shing Fac Med, Carol Yu Ctr Infect, Sch Clin Med,Dept Microbiol,State Key Lab Emerging, Hong Kong, Peoples R China
[6] Hainan Med Univ, Hainan Med Univ Univ Hong Kong Joint Lab Trop Infe, Haikou 571101, Hainan, Peoples R China
关键词
microfluidics; biosensor; infectious disease; immunoassay; point-of-care test; diagnostics; SPECIFICITY; SENSITIVITY; BRUSHES; ASSAY; SERUM;
D O I
10.1021/acssensors.3c00209
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Point-of-care tests (POCTs) are increasingly being used in field settings, particularly outdoors. The performance of current POCTs-most commonly the lateral flow immunoassay-can be adversely affected by ambient temperature and humidity. We developed a self-contained immunoassay platform-the D4 POCT-that can be conducted at the POC by integrating all reagents in a capillary-driven passive microfluidic cassette that minimizes user intervention. The assay can be imaged and analyzed on a portable fluorescence reader-the D4Scope-and provide quantitative outputs. Here, we systematically investigated the resilience of our D4 POCT to varied temperature and humidity and to physiologically diverse human whole blood samples that span a wide range of physiological hematocrit (30-65%). For all conditions, we showed that the platform maintained high sensitivity (0.05-0.41 ng/mL limits of detection). The platform also demonstrated good accuracy in reporting true analyte concentration across environmental extremes when compared to the manually operated format of the same test to detect a model analyte-ovalbumin. Additionally, we engineered an improved version of the microfluidic cassette that improved the ease-of-use of the device and shortened the time-to-result. We implemented this new cassette to create a rapid diagnostic test to detect talaromycosis infection in patients with advanced HIV disease at the POC, demonstrating comparable sensitivity and specificity to the laboratory test for the disease.
引用
收藏
页码:2228 / 2236
页数:9
相关论文
共 32 条
  • [1] [Anonymous], 1990, CLIN METHODS HIST PH, V3rd
  • [2] MP1 encodes an abundant and highly antigenic cell wall mannoprotein in the pathogenic fungus Penicillium marneffei
    Cao, L
    Chan, CM
    Lee, C
    Wong, SSY
    Yuen, KY
    [J]. INFECTION AND IMMUNITY, 1998, 66 (03) : 966 - 973
  • [3] Surface hydration: Principles and applications toward low-fouling/nonfouling biomaterials
    Chen, Shenfu
    Li, Lingyan
    Zhao, Chao
    Zheng, Jie
    [J]. POLYMER, 2010, 51 (23) : 5283 - 5293
  • [4] Sensitive biomolecule detection in lateral flow assay with a portable temperature-humidity control device
    Choi, Jane Ru
    Hu, Jie
    Feng, Shangsheng
    Abas, Wan Abu Bakar Wan
    Pingguan-Murphy, Belinda
    Xu, Feng
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 79 : 98 - 107
  • [5] Ultrasensitive point-of-care immunoassay for secreted glycoprotein detects Ebola infection earlier than PCR
    Fontes, Cassio M.
    Lipes, Barbara D.
    Liu, Jason
    Agans, Krystle N.
    Yan, Aiwei
    Shi, Patricia
    Cruz, Daniela F.
    Kelly, Garrett
    Luginbuhl, Kelli M.
    Joh, Daniel Y.
    Foster, Stephanie L.
    Heggestad, Jacob
    Hucknall, Angus
    Mikkelsen, Maiken H.
    Pieper, Carl F.
    Horstmeyer, Roarke W.
    Geisbert, Thomas W.
    Gunn, Michael D.
    Chilkoti, Ashutosh
    [J]. SCIENCE TRANSLATIONAL MEDICINE, 2021, 13 (588)
  • [6] Engineering the Surface Properties of a Zwitterionic Polymer Brush to Enable the Simple Fabrication of Inkjet-Printed Point-of-Care Immunoassays
    Fontes, Cassio M.
    Achar, Rohan K.
    Joh, Daniel Y.
    Ozer, Imran
    Bhattacharjee, Somnath
    Hucknall, Angus
    Chilkoti, Ashutosh
    [J]. LANGMUIR, 2019, 35 (05) : 1379 - 1390
  • [7] Development and evaluation of a real-time polymerase chain reaction assay for the rapid detection of Talaromyces marneffei MP1 gene in human plasma
    Ha Thuc Ai Hien
    Tran Tan Thanh
    Nguyen Thi Mai Thu
    Ashley Nguyen
    Nguyen Tat Thanh
    Nguyen Phu Huong Lan
    Simmons, Cameron
    Shikuma, Cecilia
    Nguyen Van Vinh Chau
    Thwaites, Guy
    Thuy Le
    [J]. MYCOSES, 2016, 59 (12) : 773 - 780
  • [8] Rapid test to assess the escape of SARS-CoV-2 variants of concern
    Heggestad, Jacob T.
    Britton, Rhett J.
    Kinnamon, David S.
    Wall, Simone A.
    Joh, Daniel Y.
    Hucknall, Angus M.
    Olson, Lyra B.
    Anderson, Jack G.
    Mazur, Anna
    Wolfe, Cameron R.
    Oguin, Thomas H.
    Sullenger, Bruce A.
    Burke, Thomas W.
    Kraft, Bryan D.
    Sempowski, Gregory D.
    Woods, Christopher W.
    Chilkoti, Ashutosh
    [J]. SCIENCE ADVANCES, 2021, 7 (49)
  • [9] Multiplexed, quantitative serological profiling of COVID-19 from blood by a point-of-care test
    Heggestad, Jacob T.
    Kinnamon, David S.
    Olson, Lyra B.
    Liu, Jason
    Kelly, Garrett
    Wall, Simone A.
    Oshabaheebwa, Solomon
    Quinn, Zachary
    Fontes, Cassio M.
    Joh, Daniel Y.
    Hucknall, Angus M.
    Pieper, Carl
    Anderson, Jack G.
    Naqvi, Ibtehaj A.
    Chen, Lingye
    Que, Loretta G.
    Oguin, Thomas, III
    Nair, Smita K.
    Sullenger, Bruce A.
    Woods, Christopher W.
    Burke, Thomas W.
    Sempowski, Gregory D.
    Kraft, Bryan D.
    Chilkoti, Ashutosh
    [J]. SCIENCE ADVANCES, 2021, 7 (26)
  • [10] Simple Fabrication of Antibody Microarrays on Nonfouling Polymer Brushes with Femtomolar Sensitivity for Protein Analytes in Serum and Blood
    Hucknall, Angus
    Kim, Dong-Hwan
    Rangarajan, Srinath
    Hill, Ryan T.
    Reichert, William M.
    Chilkoti, Ashutosh
    [J]. ADVANCED MATERIALS, 2009, 21 (19) : 1968 - 1971