Impact of polishing system on surface roughness of different ceramic surfaces after various pretreatments and bracket debonding

被引:3
|
作者
Jungbauer, Rebecca [1 ,2 ]
Liebermann, Anja [3 ]
Hammer, Christian M. M. [4 ,5 ]
Edelhoff, Daniel [2 ]
Proff, Peter [1 ]
Stawarczyk, Bogna [2 ]
机构
[1] Univ Med Ctr Regensburg, Dept Orthodont, Franz Josef Strauss Allee 11, D-93053 Regensburg, Germany
[2] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Prosthet Dent, Munich, Germany
[3] Univ Cologne, Univ Hosp Cologne, Fac Med, Dept Prosthet Dent, Cologne, Germany
[4] Friedrich Alexander Univ Erlangen Nurnberg, Inst Funct & Clin Anat, Erlangen, Germany
[5] Univ Fribourg, Fac Sci & Med, Anat Unit, Fribourg, Switzerland
关键词
Surface roughness; Pretreatment; Bracket debonding; Polishing; Ceramics; TENSILE BOND STRENGTH; GLOSS;
D O I
10.1007/s00784-023-05058-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveEvaluating various polishing methods after bracket debonding and excessive attachment material removal for different ceramics and pretreatments.Material and methodsZirconia (ZrO2), leucite (LEU) and lithium disilicate (LiSi) specimens were pretreated with a) silica coated alumina particles (CoJet); LEU and LiSi additionally with b) hydrofluoric acid (HF), c) Monobond Etch&Prime (MEP), d) silicium carbide grinder (SiC) before bracket bonding, shearing off, ARI evaluation, excessive attachment material removal and polishing with i) Sof-Lex Discs (Soflex), ii) polishing paste (Paste), iii) polishing set (Set). Before/after polishing surface roughness (Ra) was measured with a profilometer. Martens hardness parameter were also assessed.ResultsIrrespective of pretreatment Ra of LEU increased the most, followed by LiSi and ZrO2 (p < 0.001, SiC: p = 0.012), in accordance with the measured Martens hardness parameter. CoJet/SiC caused greater roughness as HF/MEP (p < 0.001). The ZrO2 surface was rougher after polishing with Paste/Set (p < 0.001; p = 0.047). Ra improved in the LEU/CoJet, LEU/SiC and LiSi/SiC groups with Soflex/Set (p < 0.001), in the LiSi/CoJet and LEU/HF groups by Soflex (p = 0.003, p < 0.001) and worsened by Paste (p = 0.017, p < 0.001). Polishing of HF or MEP pretreated LiSi with Set increased Ra (p = 0.001, p < 0.001), so did Paste in the LEU/MEP group (p < 0.001).ConclusionsPaste couldn't improve the surfaces. Soflex was the only method decreasing Ra on rough surfaces and not causing roughness worsening. Polishing of LEU/LiSi after MEP, LEU after HF pretreatment doesn ' t seem to have any benefit.
引用
收藏
页码:4389 / 4399
页数:11
相关论文
共 40 条
  • [1] Impact of polishing system on surface roughness of different ceramic surfaces after various pretreatments and bracket debonding
    Rebecca Jungbauer
    Anja Liebermann
    Christian M. Hammer
    Daniel Edelhoff
    Peter Proff
    Bogna Stawarczyk
    Clinical Oral Investigations, 2023, 27 : 4389 - 4399
  • [2] Comparison of feldspathic veneer surface treatments on ceramic bracket SBS, ARI and surface roughness after different debonding/polishing methods: An in vitro study
    Leao, Cecilia Sued
    Regal de Castro, Amanda Cunha
    Copello, Flavio Mendonca
    Elias, Carlos Nelson
    Junior, Terumitsu Sekito
    Sant'Anna, Eduardo Franzotti
    INTERNATIONAL ORTHODONTICS, 2021, 19 (04) : 679 - 684
  • [3] Bond Strength and Surface Roughness of Two Ceramics After Metal Bracket Debonding
    Arcas, Luciana P. B.
    Baroudi, Kusai
    de Matos, Caroline A. B.
    Ribeiro, Fabiana C.
    Silva-Concilio, Lais R.
    Amaral, Marina
    TURKISH JOURNAL OF ORTHODONTICS, 2023, 36 (03) : 194 - 198
  • [4] The Effect of Finishing and Polishing with Proprietary Vs Interchanged Polishing Kits on the Surface Roughness of Different Ceramic Materials
    Irusa, Karina F.
    Albouy, Jean-Pierre
    Cook, Ryan
    Amaya-Pajares, Silvia
    Donovan, Terence
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (03): : 267 - 272
  • [5] Effectiveness of Porcelain Polishing Methods on the Roughness and Color Stability of CAD-CAM Ceramics after Orthodontic Bracket Debonding
    Haralur, Satheesh B.
    Shiban, Abdullah Saeed
    Alqahtani, Nasser Mohammed
    MATERIALS, 2023, 16 (14)
  • [6] Surface Roughness of a Glazed Ceramic and Subjected to Different Polishing systems
    Bini, Nathalye
    Vasconcellos, Fernanda de Jesus
    Depes de Gouvea, Cresus Vinicius
    Carvalho, Waldimir
    Ferreira, Vinicius Faria
    de Oliveira, Henrique
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2011, 11 (04): : 481 - 484
  • [7] Evaluation of enamel surface integrity after orthodontic bracket debonding: comparison of three different system
    Ghaleb, Labib
    Al-Worafi, Naseem Ali
    Thawaba, Ahmed
    Abdulqader, Abbas Ahmed
    Alkamel, Aqlan
    Abdo, Yaser
    Yang, Zhao
    Noman, Nashwan
    Al-Aroomi, Maged Ali
    Yulou, Tian
    BMC ORAL HEALTH, 2024, 24 (01)
  • [8] Evaluation of enamel surface integrity after orthodontic bracket debonding: comparison of three different system
    Labib Ghaleb
    Naseem Ali Al-Worafi
    Ahmed Thawaba
    Abbas Ahmed Abdulqader
    Aqlan Alkamel
    Yaser Abdo
    Zhao Yang
    Nashwan Noman
    Maged Ali Al-Aroomi
    Tian Yulou
    BMC Oral Health, 24
  • [9] Comparative effect of three polishing systems on porcelain surface roughness after orthodontic bracket debonding and composite resin removal: An atomic force microscopy
    Qabel, Faeze
    Talaei, Riehane
    Saeedi, Saeedeh
    Ghorbani, Raheb
    Ameli, Nazila
    APOS TRENDS IN ORTHODONTICS, 2019, 9 (04) : 223 - 229
  • [10] Surface roughness of a novel "ceramic restorative cement" after treatment with different polishing techniques in vitro
    Karin Sunnegårdh-Grönberg
    J. W. V. van Dijken
    Clinical Oral Investigations, 2003, 7 (1) : 27 - 31