A novel TMR sensor based on digital lock-in amplifier technology for portable oil multipollutant detection system

被引:2
作者
He, Xiaoxi [1 ]
Li, Yuying [1 ]
Meng, Zhiqiang [1 ]
Lin, Liuyu [1 ]
Chen, Dihu [1 ]
Zhang, Mu-Shui [1 ]
Wang, Zixin [1 ]
机构
[1] Sun Yat Sen Univ, Sch Elect & Informat Technol, Guangzhou 510006, Peoples R China
关键词
Metal particles identification; Weak signal detection; Tunnel magnetoresistance (TMR) sensor; Digital lock-in amplifier (DLIA); INDUCTIVE DEBRIS SENSOR; SENSITIVITY; DIAGNOSIS; SIZE;
D O I
10.1016/j.sna.2024.115177
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Metal particles identification in lubrication oil has become a popular technology to perform the fault diagnosis and health monitoring of machinery equipment. Unfortunately, the magnetic signals induced by particles are generally weak or even submerged in heavy noise. The sensitivity of conventional inductive sensors for detecting non-ferrous particles can still be improved to better distinguish between different non-ferrous particles. Based on the above issues, this paper proposed a novel tunnel magnetoresistance (TMR) sensor based on digital lock -in amplifier (DLIA) technology to detect ferrous and multiple nonferrous metallic particles in oil under noisy conditions. Moreover, compared to conventional inductive sensor structures, the proposed method can effectively reduce the sensor volume, which is particularly necessary when considering the design of portable oil multipollutant detection system. Owing to the high resolution of TMR and outstanding versatility of DLIA for extracting weak signal overwhelmed in noise, the detection sensitivity can be improved tremendously. Extensive simulation and experimental results validated that the proposed approach was practical and effective. Based on the experimental results, the minimum values of detectable diameter could be computed as 24.76 mu m for iron particles, 81.34 mu m and 82.32 mu m for copper and aluminium particles respectively.
引用
收藏
页数:13
相关论文
共 39 条
  • [1] Ametek scientific instruments, 2024, model 7265 dsp lock-in amplifier instruction manual, product datasheet
  • [2] [Anonymous], 2023, Mdt-linear-sensors-tmr2103-datasheet-cn-v1.0
  • [3] [Anonymous], 2024, LSP02-1Y
  • [4] Inductive-Capacitive Dual-Mode Oil Detection Sensor Based on Magnetic Nanoparticle Material
    Bai, Chenzhao
    Zhang, Hongpeng
    Wang, Wenqi
    Zhao, Xupeng
    Chen, Haiquan
    Zeng, Naibin
    [J]. IEEE SENSORS JOURNAL, 2020, 20 (20) : 12274 - 12281
  • [5] Development of an online-wear-measurement for elastomer materials in a tribologically equivalent system for radial shaft seals
    Burkhart, Christoph
    Schollmayer, Tim
    van der Vorst, Bas
    Sansalone, Mickael
    Thielen, Stefan
    Sauer, Bernd
    [J]. WEAR, 2021, 476
  • [6] Cao N., 2023, Meas. Control, Patent No. 00202940231159117
  • [7] Ferrographic analysis of pivot jewel bearing in oil-bath lubrication
    Dai, Xingjian
    Wang, Yong
    Yu, Shiqiang
    [J]. WEAR, 2017, 376 : 843 - 850
  • [8] A Ferromagnetic Wear Particle Sensor Based on a Rotational Symmetry High-Gradient Magnetostatic Field
    Feng, Song
    Yang, Leilei
    Fan, Bin
    Li, Rui
    Luo, Jiufei
    Mao, Junhong
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [9] AN INDUCTIVE METHOD FOR ESTIMATING THE COMPOSITION AND SIZE OF METAL PARTICLES
    FLANAGAN, IM
    JORDAN, JR
    WHITTINGTON, HW
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1990, 1 (05) : 381 - 384
  • [10] An overview of acoustic emission inspection and monitoring technology in the key components of renewable energy systems
    He, Yunze
    Li, Mengchuan
    Meng, Zhiqiang
    Chen, Sheng
    Huang, Shoudao
    Hu, Yi
    Zou, Xiang
    [J]. MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2021, 148