A comprehensive set of ultrashort echo time magnetic resonance imaging biomarkers to assess cortical bone health: A feasibility study at clinical field strength

被引:2
作者
Jacobson, Andrea M. [1 ,2 ]
Zhao, Xuandong [3 ]
Sommer, Stefan [4 ,5 ]
Sadik, Farhan [1 ]
Warden, Stuart J. [6 ]
Newman, Christopher [3 ]
Siegmund, Thomas [7 ]
Allen, Matthew R. [8 ]
Surowiec, Rachel K. [1 ,3 ,9 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI USA
[3] Indiana Univ, Sch Med, Dept Radiol & Imaging Sci, Indianapolis, IN USA
[4] Swiss Ctr Musculoskeletal Imaging SCMI, Balgrist Campus, Zurich, Switzerland
[5] Siemens Healthineers Int AG, Adv Clin Imaging Technol ACIT, Zurich, Switzerland
[6] Indiana Univ Indianapolis, Sch Hlth & Human Sci, Dept Phys Therapy, Indianapolis, IN USA
[7] Purdue Univ, Sch Mech Engn, W Lafayette, IN USA
[8] Indiana Univ, Sch Med, Dept Anat Physiol & Cell Biol, Indianapolis, IN USA
[9] Purdue Univ, Weldon Sch Biomed Engn Radiol & Imaging Sci, 723 W Michigan St SL 220N, Indianapolis, IN 46202 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
Bone; Ultrashort echo time magnetic resonance; imaging; Bone water; Bone mineral density; High resolution peripheral quantitative; computed tomography; Porosity; MINERAL DENSITY; WATER; MRI; UTE; TOUGHNESS; FRACTURE;
D O I
10.1016/j.bone.2024.117031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Conventional bone imaging methods primarily use X-ray techniques to assess bone mineral density (BMD), focusing exclusively on the mineral phase. This approach lacks information about the organic phase and bone water content, resulting in an incomplete evaluation of bone health. Recent research highlights the potential of ultrashort echo time magnetic resonance imaging (UTE MRI) to measure cortical porosity and estimate BMD based on signal intensity. UTE MRI also provides insights into bone water distribution and matrix organization, enabling a comprehensive bone assessment with a single imaging technique. Our study aimed to establish quantifiable UTE MRI-based biomarkers at clinical field strength to estimate BMD and microarchitecture while quantifying bound water content and matrix organization. Methods: Femoral bones from 11 cadaveric specimens (n = 4 males 67-92 yrs of age, n = 7 females 70-95 yrs of age) underwent dual -echo UTE MRI (3.0 T, 0.45 mm resolution) with different echo times and high resolution peripheral quantitative computed tomography (HR-pQCT) imaging (60.7 mu m voxel size). Following registration, a 4.5 mm HR-pQCT region of interest was divided into four quadrants and used across the multi -modal images. Statistical analysis involved Pearson correlation between UTE MRI porosity index and a signal -intensity technique used to estimate BMD with corresponding HR-pQCT measures. UTE MRI was used to calculate T1 relaxation time and a novel bound water index (BWI), compared across subregions using repeated measures ANOVA. Results: The UTE MRI-derived porosity index and signal -intensity -based estimated BMD correlated with the HRpQCT variables (porosity: r = 0.73, p = 0.006; BMD: r = 0.79, p = 0.002). However, these correlations varied in strength when we examined each of the four quadrants (subregions, r = 0.11-0.71). T1 relaxometry and the BWI exhibited variations across the four subregions, though these differences were not statistically significant. Notably, we observed a strong negative correlation between T1 relaxation time and the BWI (r = -0.87, p = 0.0006). Conclusion: UTE MRI shows promise for being an innocuous method for estimating cortical porosity and BMD parameters while also giving insight into bone hydration and matrix organization. This method offers the potential to equip clinicians with a more comprehensive array of imaging biomarkers to assess bone health without the need for invasive or ionizing procedures.
引用
收藏
页数:11
相关论文
共 63 条
  • [1] Quantification of Human Cortical Bone Bound and Free Water in Vivo with Ultrashort Echo Time MR Imaging: A Model-based Approach
    Abbasi-Rad, Shahrokh
    Rad, Hamidreza Saligheh
    [J]. RADIOLOGY, 2017, 283 (03) : 861 - 871
  • [2] Erosion Identification in Metacarpophalangeal Joints in Rheumatoid Arthritis using High-Resolution Peripheral Quantitative Computed Tomography
    Al-Khoury, Yousif
    Finzel, Stephanie
    Figueiredo, Camille
    Burghardt, Andrew J.
    Stok, Kathryn S.
    Tam, Lai-Shan
    Cheng, Isaac
    Tse, Justin J.
    Manske, Sarah L.
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (200):
  • [3] Variable Flip Angle 3D Ultrashort Echo Time (UTE) T1 Mapping of Mouse Lung: A Repeatability Assessment
    Alamidi, Daniel F.
    Smailagic, Amir
    Bidar, Abdel W.
    Parker, Nicole S.
    Olsson, Marita
    Hockings, Paul D.
    Lagerstrand, Kerstin M.
    Olsson, Lars E.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (03) : 846 - 852
  • [4] In Vivo UTE-MRI Reveals Positive Effects of Raloxifene on Skeletal-Bound Water in Skeletally Mature Beagle Dogs
    Allen, Matthew R.
    Territo, Paul R.
    Lin, Chen
    Persohn, Scott
    Jiang, Lei
    Riley, Amanda A.
    McCarthy, Brian P.
    Newman, Christopher L.
    Burr, David B.
    Hutchins, Gary D.
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2015, 30 (08) : 1441 - 1444
  • [5] Ultrashort echo time (UTE) imaging with bi-component analysis: Bound and free water evaluation of bovine cortical bone subject to sequential drying
    Biswas, Reni
    Bae, Won
    Diaz, Eric
    Masuda, Koichi
    Chung, Christine B.
    Bydder, Graeme M.
    Du, Jiang
    [J]. BONE, 2012, 50 (03) : 749 - 755
  • [6] Structural features underlying raloxifene's biophysical interaction with bone matrix
    Bivi, Nicoletta
    Hu, Haitao
    Chavali, Balagopalakrishna
    Chalmers, Michael J.
    Reutter, Christopher T.
    Durst, Gregory L.
    Riley, Anna
    Sato, Masahiko
    Allen, Matthew R.
    Burr, David D.
    Dodge, Jeffrey A.
    [J]. BIOORGANIC & MEDICINAL CHEMISTRY, 2016, 24 (04) : 759 - 767
  • [7] Boskey A.L., 2013, Primer on the Metabolic Bone Diseases and Disorders of Mineral Metabolism, P49, DOI [DOI 10.1002/9781119266594.CH11, 10.1002/9781119266594.ch11]
  • [8] The utility of multi-stack alignment and 3D longitudinal image registration to assess bone remodeling in rheumatoid arthritis patients from second generation HR-pQCT scans
    Brunet, Scott C.
    Kuczynski, Michael T.
    Bhatla, Jennifer L.
    Lemay, Sophie
    Pauchard, Yves
    Salat, Peter
    Barnabe, Cheryl
    Manske, Sarah L.
    [J]. BMC MEDICAL IMAGING, 2020, 20 (01)
  • [9] AGING OF BONE TISSUE - MECHANICAL-PROPERTIES
    BURSTEIN, AH
    REILLY, DT
    MARTENS, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (01) : 82 - 86
  • [10] Ultrashort echo time magnetization transfer (UTE-MT) imaging of cortical bone
    Chang, Eric Y.
    Bae, Won C.
    Shao, Hongda
    Biswas, Reni
    Li, Shihong
    Chen, Jun
    Patil, Shantanu
    Healey, Robert
    D'Lima, Darryl D.
    Chung, Christine B.
    Du, Jiang
    [J]. NMR IN BIOMEDICINE, 2015, 28 (07) : 873 - 880