Air Pressure Impact on the Avalanche Size for Turn-to-Turn Insulation of Inverter-Fed Motors

被引:7
|
作者
Naderiallaf, Hadi [1 ]
Ji, Yatai [2 ]
Giangrande, Paolo [3 ]
Galea, Michael [4 ]
机构
[1] Univ Nottingham, Power Elect Machine & Control Grp PEMC, Nottingham NG7 2GT, England
[2] Univ Nottingham Ningbo China, Key Lab More Elect Aircraft Technol Zhejiang Prov, Ningbo 315100, Peoples R China
[3] Univ Bergamo, Dept Engn & Appl Sci, I-24044 Dalmine, Italy
[4] Univ Malta, Dept Ind Elect Power Convers, Msida 2080, Malta
关键词
Insulation; Partial discharges; Discharges (electric); Electric fields; Ionization; Atmospheric modeling; Wires; Air pressure; avalanche breakdown; electric machines; finite element analysis; insulation; partial discharges (PDs); reliability; ELECTRICAL MACHINES; PARTIAL DISCHARGES;
D O I
10.1109/TDEI.2023.3324287
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article endeavors to illuminate the variations of various streamer inception parameters (SIPs) with respect to air pressure based on Schumann's streamer inception criterion (SCSIC). The results based on measured partial discharge inception voltage (PDIV) values and using electric field distribution obtained via electrostatic simulations and ionization swarm parameters reveal that the Schumann constant, K , which is the natural logarithm of the threshold number of electrons determining the transition from Townsend to streamer discharge, and consequently, the critical avalanche size ( N-c ) increase with air pressure reduction. Different SIPs such as critical field line length (CFLL), effective ionization coefficient of air ( alpha(eff) ), PD inception field ( E-inc ), firing voltage ( V-firing ) across the critical field line (CFL), and K and N-c are analyzed extensively as a function of air pressure. In light of the findings of this contribution, it is demonstrated that the derived K functions as a function of air pressure can improve drastically the accuracy of PDIV prediction in particular for low air pressures rather than a single K parameter value obtained at ground level. The study's findings represent a guideline for electrical machine designers to improve the insulation design of electrical machines employed in the more electric aircraft (MEA) applications.
引用
收藏
页码:85 / 94
页数:10
相关论文
共 23 条
  • [1] Temperature Impact on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors: From Ground Level to Cruising Altitude
    Naderiallaf, Hadi
    Ji, Yatai
    Giangrande, Paolo
    Galea, Michael
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (02) : 1044 - 1053
  • [2] Modeling Humidity Impact on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors at Different Temperatures
    Naderiallaf, H.
    Ji, Y.
    Giangrande, P.
    Galea, M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (03) : 1573 - 1582
  • [3] Modeling Air Pressure Impact on PDIV for Rectangular Wire Turn-to-Turn Insulation of Inverter-Fed Motors Under Different Voltage Waveform Excitations
    Naderiallaf, Hadi
    Degano, Michele
    Gerada, Christopher
    IEEE ACCESS, 2024, 12 : 176232 - 176246
  • [4] Fillet Radius Impact of Rectangular Insulated Wires on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors
    Naderiallaf, Hadi
    Degano, Michele
    Gerada, Chris
    Gerada, David
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (04) : 2084 - 2093
  • [5] PDIV Modeling for Rectangular Wire Turn-to-Turn Insulation of Inverter Fed Motors Through Thermal Aging
    Naderiallaf, Hadi
    Degano, Michele
    Gerada, Chris
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (01) : 550 - 559
  • [6] PD Electromagnetic Emission of Turn-to-Turn Insulation in Inverter-Fed Motor
    Ma, Shijin
    Wang, Peng
    Cavallini, Andrea
    Zhu, Yingwei
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (06) : 3049 - 3056
  • [7] Voltage rise rate-related generalised probabilistic lifetime model of turn-to-turn insulation in inverter-fed motors
    Yang, Yan
    Bai, Xueyang
    Lei, Yuxing
    Liu, Kai
    Wu, Guangning
    HIGH VOLTAGE, 2024, 9 (01) : 46 - 55
  • [8] Methods to decrease turn-to-turn voltage of motors fed by inverter drives
    Obata, Koji
    Takeuchi, Ryozo
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 1590 - 1593
  • [9] Assessment of Edgewise Insulated Wire Bend Radius Impact on Dielectric Properties of Turn-to-Turn Insulation Through Thermal Aging
    Naderiallaf, H.
    Degano, M.
    Gerada, C.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (01) : 419 - 428
  • [10] The impact of test voltage waveform in determining the repetitive partial discharge inception voltage of Type I turn/turn insulation used in inverter-fed induction motors
    Lusuardi, Luca
    Cavallini, Andrea
    Caprara, Andrea
    Bardelli, Fabrizio
    Cattazzo, Andrea
    2018 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2018, : 478 - 481