Sound Level Changes the Auditory Cortical Activation Detected with Functional Near-Infrared Spectroscopy

被引:2
作者
Sheffield, Sterling W. [1 ]
Larson, Eric [2 ]
Butera, Iliza M. [3 ]
DeFreese, Andrea [4 ]
Rogers, Baxter P. [5 ]
Wallace, Mark T. [6 ]
Stecker, G. Christopher [7 ]
Lee, Adrian K. C. [2 ,8 ]
Gifford, Rene H. [4 ]
机构
[1] Univ Florida, Dept Speech Language & Hearing Sci, 1225 Ctr Dr,Room 2130, Gainesville, FL 32160 USA
[2] Univ Washington, Inst Learning & Brain Sci, Seattle, WA USA
[3] Vanderbilt Univ, Vanderbilt Brain Inst, Nashville, TN USA
[4] Vanderbilt Univ, Dept Hearing & Speech Sci, Sch Med, Nashville, TN USA
[5] Vanderbilt Univ, Dept Radiol & Radiol Sci, Nashville, TN USA
[6] Vanderbilt Univ, Dept Psychol, Nashville, TN USA
[7] Boys Town Natl Res Hosp, Omaha, NE USA
[8] Univ Washington, Dept Speech & Hearing Sci, Seattle, WA USA
关键词
Functional near-infrared spectroscopy; Cochlear implants; Stimulus level; Loudness ratings; HEMODYNAMIC-RESPONSES; LOUDNESS GROWTH; FMRI ACTIVATION; SPEECH; INTENSITY; CORTEX; NOISE; EEG;
D O I
10.1007/s10548-023-00981-w
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BackgroundFunctional near-infrared spectroscopy (fNIRS) is a viable non-invasive technique for functional neuroimaging in the cochlear implant (CI) population; however, the effects of acoustic stimulus features on the fNIRS signal have not been thoroughly examined. This study examined the effect of stimulus level on fNIRS responses in adults with normal hearing or bilateral CIs. We hypothesized that fNIRS responses would correlate with both stimulus level and subjective loudness ratings, but that the correlation would be weaker with CIs due to the compression of acoustic input to electric output.MethodsThirteen adults with bilateral CIs and 16 with normal hearing (NH) completed the study. Signal-correlated noise, a speech-shaped noise modulated by the temporal envelope of speech stimuli, was used to determine the effect of stimulus level in an unintelligible speech-like stimulus between the range of soft to loud speech. Cortical activity in the left hemisphere was recorded.ResultsResults indicated a positive correlation of cortical activation in the left superior temporal gyrus with stimulus level in both NH and CI listeners with an additional correlation between cortical activity and perceived loudness for the CI group. The results are consistent with the literature and our hypothesis.ConclusionsThese results support the potential of fNIRS to examine auditory stimulus level effects at a group level and the importance of controlling for stimulus level and loudness in speech recognition studies. Further research is needed to better understand cortical activation patterns for speech recognition as a function of both stimulus presentation level and perceived loudness.
引用
收藏
页码:686 / 697
页数:12
相关论文
共 56 条
[1]   Pre-operative Brain Imaging Using Functional Near-Infrared Spectroscopy Helps Predict Cochlear Implant Outcome in Deaf Adults [J].
Anderson, Carly A. ;
Wiggins, Ian M. ;
Kitterick, Padraig T. ;
Hartley, Douglas E. H. .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2019, 20 (05) :511-528
[2]   Functional hemispheric specialization in processing phonemic and prosodic auditory changes in neonates [J].
Arimitsu, Takeshi ;
Uchida-Ota, Mariko ;
Yagihashi, Tatsuhiko ;
Kojima, Shozo ;
Watanabe, Shigeru ;
Hokuto, Isamu ;
Ikeda, Kazushige ;
Takahashi, Takao ;
Minagawa-Kawai, Yasuyo .
FRONTIERS IN PSYCHOLOGY, 2011, 2
[3]   CONTROLLING THE FALSE DISCOVERY RATE - A PRACTICAL AND POWERFUL APPROACH TO MULTIPLE TESTING [J].
BENJAMINI, Y ;
HOCHBERG, Y .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1995, 57 (01) :289-300
[4]   Functional localization of audiovisual speech using near infrared spectroscopy [J].
Butera, Iliza M. ;
Larson, Eric D. ;
DeFreese, Andrea J. ;
Lee, Adrian Kc ;
Gifford, Rene H. ;
Wallace, Mark T. .
BRAIN TOPOGRAPHY, 2022, 35 (04) :416-430
[5]   Increased cross-modal functional connectivity in cochlear implant users [J].
Chen, Ling-Chia ;
Puschmann, Sebastian ;
Debener, Stefan .
SCIENTIFIC REPORTS, 2017, 7
[6]   Efficient Data Extraction Method for Near-Infrared Spectroscopy (NIRS) Systems With High Spatial and Temporal Resolution [J].
Choi, Jong-Kwan ;
Choi, Min-Gyu ;
Kim, Jae-Myoung ;
Bae, Hyeon-Min .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2013, 7 (02) :169-177
[7]   Intensity Coding in Electric Hearing: Effects of Electrode Configurations and Stimulation Waveforms [J].
Chua, Tiffany Elise H. ;
Bachman, Mark ;
Zeng, Fan-Gang .
EAR AND HEARING, 2011, 32 (06) :679-689
[8]   NIRS-SPM: Statistical parametric mapping for near-infrared spectroscopy [J].
Chul, Jong ;
Tak, Sungho ;
Jang, Kwang Eun ;
Jung, Jinwook ;
Jang, Jaeduck .
NEUROIMAGE, 2009, 44 (02) :428-447
[9]   SYSTEM FOR LONG-TERM MEASUREMENT OF CEREBRAL BLOOD AND TISSUE OXYGENATION ON NEWBORN-INFANTS BY NEAR-INFRARED TRANS-ILLUMINATION [J].
COPE, M ;
DELPY, DT .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (03) :289-294
[10]   The contour test of loudness perception [J].
Cox, RM ;
Alexander, GC ;
Taylor, IM ;
Gray, GA .
EAR AND HEARING, 1997, 18 (05) :388-400