Impact of cardiac size on diagnostic performance of single-photon emission computed tomography myocardial perfusion imaging: insights from the REgistry of Fast Myocardial Perfusion Imaging with NExt generation single-photon emission computed tomography

被引:0
|
作者
Randazzo, Michael [1 ]
Elias, Pierre [2 ]
Poterucha, Timothy [2 ]
Sharir, Tali [3 ]
Fish, Matthews [4 ]
Ruddy, Terrence [5 ]
Kaufmann, Philipp [6 ]
Sinusas, Albert [7 ]
Miller, Edward [7 ]
Bateman, Timothy [8 ]
Dorbala, Sharmila [9 ]
Di Carli, Marcelo [9 ]
Castillo, Michelle [2 ]
Liang, Joanna [10 ]
Miller, Robert [10 ,11 ]
Dey, Damini [10 ]
Berman, Daniel [10 ]
Slomka, Piotr [10 ]
Einstein, Andrew [2 ,12 ]
机构
[1] Univ Chicago, Med Ctr, Dept Med, Sect Cardiol, Chicago, IL USA
[2] Columbia Univ, NewYork Presbyterian Hosp, Irving Med Ctr, Dept Med,Seymour Paul & Gloria Milstein Div Cardio, 622 West 168th St,PH 10-203, New York, NY 10032 USA
[3] Assuta Med Ctr, Dept Nucl Cardiol, Tel Aviv, Israel
[4] Oregon Heart & Vasc Inst, Sacred Heart Med Ctr, Springfield, OR USA
[5] Univ Ottawa Heart Inst, Div Cardiol, Ottawa, ON, Canada
[6] Univ Hosp Zurich, Dept Nucl Med, Cardiac Imaging, Zurich, Switzerland
[7] Yale Univ, Sch Med, Dept Internal Med, Sect Cardiovasc Med, New Haven, CT USA
[8] Cardiovasc Imaging Technol LLC, Kansas City, MO USA
[9] Brigham & Womens Hosp, Dept Radiol, Div Nucl Med & Mol Imaging, Boston, MA USA
[10] Cedars Sinai Med Ctr, Dept Imaging Med & Biomed Sci, Los Angeles, CA USA
[11] Univ Calgary, Libin Cardiovasc Inst, Dept Cardiac Sci, Calgary, AB, Canada
[12] Columbia Univ, NewYork Presbyterian Hosp, Irving Med Ctr, Dept Radiol, 622 West 168th St,PH 10-203, New York, NY 10032 USA
基金
美国国家卫生研究院;
关键词
SPECT MPI; left ventricular size; diagnostic performance; CORONARY-ARTERY-DISEASE; CARDIOVASCULAR MAGNETIC-RESONANCE; ISCHEMIC-HEART-DISEASE; RISK STRATIFICATION; NUCLEAR CARDIOLOGY; EJECTION FRACTION; SPECT; ACCURACY; WOMEN; ECHOCARDIOGRAPHY;
D O I
10.1093/ehjci/jeae055
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Variation in diagnostic performance of single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) has been observed, yet the impact of cardiac size has not been well characterized. We assessed whether low left ventricular volume influences SPECT MPI's ability to detect obstructive coronary artery disease (CAD) and its interaction with age and sex. Methods and results A total of 2066 patients without known CAD (67% male, 64.7 +/- 11.2 years) across nine institutions underwent SPECT MPI with solid-state scanners followed by coronary angiography as part of the REgistry of Fast Myocardial Perfusion Imaging with NExt Generation SPECT. Area under receiver-operating characteristic curve (AUC) analyses evaluated the performance of quantitative and visual assessments according to cardiac size [end-diastolic volume (EDV); <20th vs. >= 20th population or sex-specific percentiles], age (<75 vs. >= 75 years), and sex. Significantly decreased performance was observed in patients with low EDV compared with those without (AUC: population 0.72 vs. 0.78, P = 0.03; sex-specific 0.72 vs. 0.79, P = 0.01) and elderly patients compared with younger patients (AUC 0.72 vs. 0.78, P = 0.03), whereas males and females demonstrated similar AUC (0.77 vs. 0.76, P = 0.67). The reduction in accuracy attributed to lower volumes was primarily observed in males (sex-specific threshold: EDV 0.69 vs. 0.79, P = 0.01). Accordingly, a significant decrease in AUC, sensitivity, specificity, and negative predictive value for quantitative and visual assessments was noted in patients with at least two characteristics of low EDV, elderly age, or male sex. Conclusion Detection of CAD with SPECT MPI is negatively impacted by small cardiac size, most notably in elderly and male patients.
引用
收藏
页码:996 / 1006
页数:11
相关论文
共 50 条
  • [41] Myocardial perfusion imaging using single-photon emission computed tomography with cadmium-zinc-telluride technology
    Konsek-Komorowska, Sonia J.
    Peczkowska, Mariola
    Cwikla, Jaroslaw B.
    NUCLEAR MEDICINE REVIEW, 2022, 25 (02) : 119 - 126
  • [42] Appropriateness of referrals for single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) in Iran
    Gholamrezanezhad, Ali
    Shirafkan, Ahmadali
    Mirpour, Sahar
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2011, 19 (01): : 1 - 5
  • [43] Accuracy of single-photon emission computed tomography myocardial perfusion imaging in patients with stents in native coronary arteries
    Milavetz, JJ
    Miller, TD
    Hodge, DO
    Holmes, DR
    Gibbons, RJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (07): : 857 - 861
  • [44] Predictive Value of Myocardial Perfusion Single-Photon Emission Computed Tomography and the Impact of Renal Function on Cardiac Death
    Hakeem, Abdul
    Bhatti, Sabha
    Dillie, Kathryn Sullivan
    Cook, Jeffrey R.
    Samad, Zainab
    Roth-Cline, Michelle D.
    Chang, Su Min
    CIRCULATION, 2008, 118 (24) : 2540 - 2549
  • [45] Quality of myocardial perfusion single-photon emission tomography imaging: multicentre evaluation with a cardiac phantom
    Heikkinen, J
    Ahonen, A
    Kuikka, JT
    Rautio, P
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (10) : 1289 - 1297
  • [46] Differentiation of myocardial ischemia and infarction assessed by dynamic computed tomography perfusion imaging and comparison with cardiac magnetic resonance and single-photon emission computed tomography
    Yuki Tanabe
    Teruhito Kido
    Teruyoshi Uetani
    Akira Kurata
    Tamami Kono
    Akiyoshi Ogimoto
    Masao Miyagawa
    Tsutomu Soma
    Kenya Murase
    Hirotaka Iwaki
    Teruhito Mochizuki
    European Radiology, 2016, 26 : 3790 - 3801
  • [47] Quality of myocardial perfusion single-photon emission tomography imaging: Multicentre evaluation with a cardiac phantom
    Heikkinen, Jari
    Ahonen, Aapo
    Kuikka, Jyrki T.
    Rautio, Pentti
    European Journal of Nuclear Medicine and Molecular Imaging, 1999, 26 (10): : 1289 - 1297
  • [48] Differentiation of myocardial ischemia and infarction assessed by dynamic computed tomography perfusion imaging and comparison with cardiac magnetic resonance and single-photon emission computed tomography
    Tanabe, Yuki
    Kido, Teruhito
    Uetani, Teruyoshi
    Kurata, Akira
    Kono, Tamami
    Ogimoto, Akiyoshi
    Miyagawa, Masao
    Soma, Tsutomu
    Murase, Kenya
    Iwaki, Hirotaka
    Mochizuki, Teruhito
    EUROPEAN RADIOLOGY, 2016, 26 (11) : 3790 - 3801
  • [49] Quality of myocardial perfusion single-photon emission tomography imaging: multicentre evaluation with a cardiac phantom
    Jari Heikkinen
    Aapo Ahonen
    Jyrki T. Kuikka
    Pentti Rautio
    European Journal of Nuclear Medicine, 1999, 26 : 1289 - 1297
  • [50] Single-Photon Emission Computed Tomography Perfusion Imaging Is Using a "Warranty Period" Warranted?
    Kottam, Anupama
    Williams, Kim Allan, Sr.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2010, 3 (05) : 505 - 506