Assessment of the 4-meter walk test test-retest reliability and concurrent validity and its correlation with the five sit-to-stand test in chronic ambulatory stroke survivors

被引:8
|
作者
Cabanas-Valdes, Rosa [1 ]
Garcia-Rueda, Laura [2 ]
Salgueiro, Carina [1 ,5 ]
Perez-Bellmunt, Albert [3 ]
Rodriguez-Sanz, Jacobo [3 ]
Lopez-de-Cells, Carlos [4 ]
机构
[1] Univ Int Catalunya, Fac Med & Hlth Sci, Physiotherapy Dept, Sant Cugat Del Valles, Barcelona, Spain
[2] Univ Int Catalunya, PhD Program, Sant Cugat Del Valles, Barcelona, Spain
[3] Univ Int Catalunya, Basic Sci Dept, Actium Funct Anat Res Grp, Campus St Cugat, Sant Cugat Del Valles, Barcelona, Spain
[4] Fundacio Inst Univ recerca Atencio Primaria Salut, Barcelona, Spain
[5] Clin Neurorehabil, Sant Cugat Del Valles, Barcelona, Spain
关键词
4-meter walking test; 10-meter walking test; Sit to stand; Stroke; Gait speed; 5 times sit to stand; 4-MWT; 10-MWT; Reliability; Concurrent validity; GAIT SPEED; PERFORMANCE; DISTANCE; PREDICTOR; MOBILITY; HEALTHY; PEOPLE;
D O I
10.1016/j.gaitpost.2023.01.014
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: The 4-meter walk test (4-MWT) is a widely used measure to assess gait speed in the elderly but has not been validated for stroke survivors to date. Objectives: To assess the test-retest reliability and concurrent validity of the 4-MWT compared to the 10-meter walk test (10-MWT) as a measure of gait speed in chronic post-stroke. Secondary outcome measure: to assess the correlation of both gait measures with the 5 times sit-to-stand test (5TSTS).Methods: A cross-sectional observational study was conducted. Reliability was assessed by intraclass correlation coefficient (ICC2,1), standard error of measurement (SEM) and minimal detectable change (MDC-95%). Bland & Altman analysis was used to quantify agreement between the 4-MWT and the 10-MWT. Two consecutive walking trials of the 4-MWT and 10-MWT followed by 5TSTS were performed all on the same day. A single researcher made all measurements.Results: Thirty-six chronic ambulatory post-stroke (average age 58.56 +/- 11.28 years) were analyzed at their self-selected walking speed with a dynamic start. The 4-MWT showed excellent concurrent validity and test-retest reliability: ICC2.1 = 0.991 (95% CI: 0.983, 0.996); SEM= 0.032 and MDC-95% = 0.090 m/second) with a strong positive correlation with the 10-MWT (r = 0.957, p < 0.001). The Bland & Altman analysis showed a concordance of-0.05 m/second bias (p = 0.039) (95% limits of agreement: 0.20 to-0.29 m/second). The paired t-test showed no statistically significant difference in the mean of both walking tests (p < 0.091). How-ever, there was only moderate correlation between the two gait assessments and the 5TSTS.Conclusions: This study indicates excellent test-retest reliability concurrent validity and strong correlation be-tween 4-MWT and 10-MWT with a dynamic start at comfortable speed. The 4-MWT could be used as a measure of gait speed in both outpatients and home settings in chronic ambulatory stroke survivors.
引用
收藏
页码:8 / 13
页数:6
相关论文
共 50 条
  • [1] Concurrent Validity and Test-Retest Reliability of the 3-Meter Backward Walk Test in Stroke Survivors
    Kapan, Ali
    Ristic, Milos
    Yang, Lin
    Kranz, Gottfried
    Waldhoer, Thomas
    HEALTHCARE, 2023, 11 (23)
  • [2] Test-Retest Reliability and Concurrent Validity of the 30 second Sit to Stand Test in Adolescents
    Robinson, Katie J.
    Lubans, David R.
    Mavilidi, Myrto F.
    Ortega, Francisco B.
    Riley, Nicholas
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2024, 28 (01) : 109 - 118
  • [3] Test-Retest Reliability and Validity of 1-Minute Sit-to-Stand Test in Patients With Chronic Heart Failure
    Tanriverdi, Aylin
    Kahraman, Buse Ozcan
    Ozpelit, Ebru
    Savci, Sema
    HEART LUNG AND CIRCULATION, 2023, 32 (04): : 518 - 524
  • [4] The test-retest reliability and concurrent validity of the five times sit to stand test and step test in older adults with total hip arthroplasty
    Ozden, Fatih
    Coskun, Gokhan
    Bakirhan, Serkan
    EXPERIMENTAL GERONTOLOGY, 2020, 142
  • [5] TEST-RETEST RELIABILITY OF THE FIVE-REPETITION SIT-TO-STAND TEST: A SYSTEMATIC REVIEW OF THE LITERATURE INVOLVING ADULTS
    Bohannon, Richard W.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2011, 25 (11) : 3205 - 3207
  • [6] Reliability and validity of the 4-meter walk test in patients with multiple sclerosis
    Ozkan, Taskin
    Unluer, Nezehat Ozgul
    Ates-Sari, Yasemin
    Hangun, Suleyman Furkan
    Vural, Gonul
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2024, 87
  • [7] Test-Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adults
    Jerez-Mayorga, Daniel
    Huerta-Ojeda, Alvaro
    Javier Chirosa-Rios, Luis
    Guede-Rojas, Francisco
    Guzman-Guzman, Iris Paola
    Intelangelo, Leonardo
    Miranda-Fuentes, Claudia
    Delgado-Floody, Pedro
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (13)
  • [8] 5-Repetition Sit-to-Stand Test in Subjects With Chronic Stroke: Reliability and Validity
    Mong, Yiqin
    Teo, Tilda W.
    Ng, Shamay S.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 91 (03): : 407 - 413
  • [9] TEST-RETEST RELIABILITY OF SIT-TO-STAND PERFORMANCE MEASURES WITH A PENDANT-WORN ACCELEROMETER
    Zhang Wei
    Regterschot, G. Ruben H.
    Zijlstra, Wiebren
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2012, 20 : S180 - S181
  • [10] Test-retest reliability, concurrent validity and correlates of the two-minute walk test in outpatients with psychosis
    Vancampfort, Davy
    Kimbowa, Samuel
    Basangwa, David
    Smith, Lee
    Stubbs, Brendon
    Van Damme, Tine
    De Hert, Marc
    Mugisha, James
    PSYCHIATRY RESEARCH, 2019, 282