A hybrid FDTD/MoM algorithm with a non-uniform grid for MRI RF coil design

被引:3
作者
Liu, Yang [1 ,2 ]
Wang, Qiuliang [1 ,2 ]
Liu, Feng [3 ]
机构
[1] Chinese Acad Sci, Inst Elect Engn, Key Lab Appl Superconduct, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Sch Elect Elect & Commun Engn, Beijing 100049, Peoples R China
[3] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld 4072, Australia
基金
中国国家自然科学基金;
关键词
RF coil; Hybrid method; FDTD; MoM; Numerical analysis; ELECTROMAGNETIC SCATTERING; HUMAN HEAD; FIELD;
D O I
10.1016/j.mri.2022.10.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In ultra-high-field (UHF) magnetic resonance imaging (MRI) applications, the design and analysis of highfrequency radio frequency (RF) coils requires full-wave electromagnetic (EM) methods that can handle complex field-tissue interactions. Using a Huygens' equivalent surface, the Method of Moments (MoM) and the FiniteDifference Time-Domain (FDTD) algorithm can be combined to accurately model the high-frequency RF coils. In previous research, a uniform FDTD mesh structure was considered, providing a compromised solution for coiltissue interactions. This paper proposes a hybrid FDTD/MoM algorithm with non-uniform meshes. The fine mesh domain is set at the Huygens' surface, and the other domain uses coarse meshes. The proposed algorithms are strictly validated, and their computational performance is compared against conventional methods. Results show that the new algorithm can improve the calculation efficiency without losing accuracy. Specifically, compared with the uniform FDTD method, the numerical difference between both hybrid methods remains at 3.2%. Still, the calculation time of the non-uniform grid algorithm is reduced by 64.2%, demonstrating the effectiveness of the new algorithm for modeling RF coils for UHF-MRI applications.
引用
收藏
页码:75 / 84
页数:10
相关论文
共 41 条
[21]   Microstrip RF surface coil design for extremely high-field MRI and spectroscopy [J].
Zhang, XL ;
Ugurbil, K ;
Chen, W .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :443-450
[22]   Flow uniformizing distribution panel design based on a non-uniform porosity distribution [J].
Choi, M. K. ;
Lim, Y. B. ;
Lee, H. W. ;
Jung, H. ;
Lee, J. W. .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2014, 130 :41-47
[23]   An inverse methodology for high-frequency RF coil design for MRI with de-emphasized B1 fields [J].
Xu, B ;
Wei, Q ;
Liu, F ;
Crozier, S .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (09) :1582-1587
[24]   RF Head Coil Design With Improved RF Magnetic Near-Fields Uniformity for Magnetic Resonance Imaging (MRI) Systems [J].
Sohn, Sung-Min ;
DelaBarre, Lance ;
Gopinath, Anand ;
Vaughan, John Thomas .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2014, 62 (08) :1784-1789
[25]   Reduction of turbine tip clearance losses at design and off-design incidences by non-uniform tip injection [J].
Gao, Jie ;
Zheng, Qun ;
Liu, Yunning ;
Zhao, Zhan .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2014, 228 (08) :889-902
[26]   A novel hybrid design algorithm for spiral coil energy piles that considers groundwater advection [J].
Go, Gyu-Hyun ;
Lee, Seung-Rae ;
Kang, Han-Byul ;
Yoon, Seok ;
Kim, Min-Jun .
APPLIED THERMAL ENGINEERING, 2015, 78 :196-208
[27]   Stability and Accuracy of Power-series Method for One-dimensional Heat Conduction with Non-uniform Grid Systems [J].
Fukuyo, Kazuhiro .
HEAT TRANSFER-ASIAN RESEARCH, 2005, 34 (07) :470-480
[28]   Design Decoupling Methods of Multichannel Phased Array Receive Only RF Coil for Different Structures of 1.5T MRI [J].
Dapkar, Radhika ;
Ugle, Niket ;
Bagchi, Soumendu ;
Bhuiya, Tapas ;
Kulkarni, A. M. ;
Gaikwad, Sandeep .
2018 INTERNATIONAL CONFERENCE ON ADVANCES IN COMMUNICATION AND COMPUTING TECHNOLOGY (ICACCT), 2018, :606-610
[29]   Versatile coil design and positioning of transverse-field RF surface coils for clinical 1.5-T MRI applications [J].
M. Alfonsetti ;
V. Clementi ;
S. Iotti ;
G. Placidi ;
R. Lodi ;
B. Barbiroli ;
A. Sotgiu ;
M. Alecci .
Magnetic Resonance Materials in Physics, Biology and Medicine, 2005, 18 :69-75
[30]   An inverse methodology for high frequency RF head coil design with pre-emphasized B1 field in MRI [J].
Xu, B ;
Crozier, S ;
Li, BK ;
Wei, Q ;
Liu, F .
PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 :1128-1131