Handheld Biosensor System Based on a Gradient Grating Period Guided-Mode Resonance Device

被引:0
作者
Chiang, Chien Chieh [1 ]
Tseng, Wen-Chun [1 ,2 ]
Tsai, Wen-Tsung [1 ]
Huang, Cheng-Sheng [1 ]
机构
[1] Natl Yang Ming Chiao Tung Univ, Dept Mech Engn, Hsinchu 30010, Taiwan
[2] InnoLux Co, 12 Kezhong Rd, Zhunan Township 350401, Miaoli County, Taiwan
来源
BIOSENSORS-BASEL | 2024年 / 14卷 / 01期
关键词
handheld biosensor device; optical biosensor; guided-mode resonance; albumin; creatinine; OPTICAL BIOSENSORS; SENSORS;
D O I
10.3390/bios14010021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Handheld biosensors have attracted substantial attention for numerous applications, including disease diagnosis, drug dosage monitoring, and environmental sensing. This study presents a novel handheld biosensor based on a gradient grating period guided-mode resonance (GGP-GMR) sensor. Unlike conventional GMR sensors, the proposed sensor's grating period varies along the device length; hence, the resonant wavelength varies linearly along the device length. If a GGP-GMR sensor is illuminated with a narrow band of light at normal incidence, the light resonates and reflects at a specific period but transmits at other periods; this can be observed as a dark band by using a complementary metal oxide semiconductor (CMOS) underneath the sensor. The concentration of a target analyte can be determined by monitoring the shift of this dark band. We designed and fabricated a handheld device incorporating a light-emitting diode (LED) light source, the necessary optics, an optofluidic chip with an embedded GGP-GMR sensor, and a CMOS. LEDs with different beam angles and bandpass filters with different full width at half maximum values were investigated to optimize the dark band quality and improve the accuracy of the subsequent image analysis. Substrate materials with different refractive indices and waveguide thicknesses were also investigated to maximize the GGP-GMR sensor's figure of merit. Experiments were performed to validate the proposed handheld biosensor, which achieved a limit of detection (LOD) of 1.09 x 10-3 RIU for bulk solution measurement. The sensor's performance in the multiplexed detection of albumin and creatinine solutions at concentrations of 0-500 mu g/mL and 0-10 mg/mL, respectively, was investigated; the corresponding LODs were 0.66 and 0.61 mu g/mL.
引用
收藏
页数:12
相关论文
共 38 条
  • [1] REFLECTION OF A BEAM OF FINITE SIZE FROM A CORRUGATED WAVE-GUIDE
    AVRUTSKY, IA
    SYCHUGOV, VA
    [J]. JOURNAL OF MODERN OPTICS, 1989, 36 (11) : 1527 - 1539
  • [2] Sensitivity model for predicting photonic crystal biosensor performance
    Block, Ian D.
    Ganesh, Nikhil
    Lu, Meng
    Cunningham, Brian T.
    [J]. IEEE SENSORS JOURNAL, 2008, 8 (3-4) : 274 - 280
  • [3] Review of Integrated Optical Biosensors for Point-of-Care Applications
    Chen, Yung-Tsan
    Lee, Ya-Chu
    Lai, Yao-Hsuan
    Lim, Jin-Chun
    Huang, Nien-Tsu
    Lin, Chih-Ting
    Huang, Jian-Jang
    [J]. BIOSENSORS-BASEL, 2020, 10 (12):
  • [4] Label-free optical resonant sensors for biochemical applications
    Ciminelli, Caterina
    Campanella, Clarissa Martina
    Dell'Olio, Francesco
    Campanella, Carlo Edoardo
    Armenise, Mario Nicola
    [J]. PROGRESS IN QUANTUM ELECTRONICS, 2013, 37 (02) : 51 - 107
  • [5] Optical biosensors: where next and how soon?
    Cooper, Matthew A.
    [J]. DRUG DISCOVERY TODAY, 2006, 11 (23-24) : 1061 - 1067
  • [6] Recent Advances in Biosensing With Photonic Crystal Surfaces: A Review
    Cunningham, Brian T.
    Zhang, Meng
    Zhuo, Yue
    Kwon, Lydia
    Race, Caitlin
    [J]. IEEE SENSORS JOURNAL, 2016, 16 (10) : 3349 - 3366
  • [7] Cunningham BT, 2009, LABEL-FREE BIOSENSORS: TECHNIQUES AND APPLICATIONS, P1, DOI 10.1017/CBO9780511626531.003
  • [8] Sensitive optical biosensors for unlabeled targets: A review
    Fan, Xudong
    White, Ian M.
    Shopova, Siyka I.
    Zhu, Hongying
    Suter, Jonathan D.
    Sun, Yuze
    [J]. ANALYTICA CHIMICA ACTA, 2008, 620 (1-2) : 8 - 26
  • [9] A Compact Detection Platform Based on Gradient Guided-Mode Resonance for Colorimetric and Fluorescence Liquid Assay Detection
    Gao, Jing-Jhong
    Chiu, Ching-Wei
    Wen, Kuo-Hsing
    Huang, Cheng-Sheng
    [J]. SENSORS, 2021, 21 (08)
  • [10] Direct optical detection in bioanalysis: an update
    Gauglitz, Guenter
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (06) : 2363 - 2372