Lanthanum Sulfide Nanorods Modified Glassy Carbon Electrode as Non-Enzymatic Biosensor for Xanthine

被引:1
|
作者
Javeed, Zainab [1 ]
Ibrahim, Muhammad [1 ]
Iqbal, Muhammad Faisal [2 ]
Nawaz, Rahat [3 ]
Hussain, Dilshad [4 ]
Ayub, Muhammad [5 ]
Ashiq, Muhammad Naeem [3 ]
Majeed, Saadat [3 ]
Najam-ul-Haq, Muahmmad [3 ]
Fatima, Batool [1 ]
机构
[1] Bahauddin Zakariya Univ, Dept Biochem, Multan 60800, Pakistan
[2] Zhejiang Normal Univ, Coll Chem & Mat Sci, Jinhua 321004, Peoples R China
[3] Bahauddin Zakariya Univ, Inst Chem Sci, Multan 60800, Pakistan
[4] Univ Karachi, HEJ Res Inst Chem, Int Ctr Chem & Biol Sci, Karachi 75270, Pakistan
[5] Univ Balochistan, Inst Biochem, Quetta, Pakistan
关键词
REDUCED GRAPHENE OXIDE; URIC-ACID; MONITORING XANTHINE; NANOCOMPOSITE; HYPOXANTHINE; SENSOR; HETEROPOLYACIDS; NANOPARTICLES; SERUM;
D O I
10.1149/1945-7111/ad0c69
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Xanthine detection is crucial for the diagnosis of metabolic disorders like xanthinuria and gout. Xanthinuria is due to xanthine stones in the urinary tract. Earlier detection of xanthine levels in human blood can minimize the risks. In this research, a non-enzymatic xanthine sensor is fabricated by depositing different concentrations of lanthanum sulfide nanoparticles on a glassy carbon electrode (GCE). Lanthanum sulfide (La2S3) nanorods are synthesized by a simple hydrothermal method and characterized by X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDS). The effect of pH, scan rates, and xanthine concentration on the peak current is examined. La2S3-modified GCE shows good conductivity, a large surface area, fast electron transfer, and promising sensing capability for xanthine detection. The highest anodic peak for xanthine is observed at a 1 mV s-1 scan rate. The la2S3-based sensor exhibits a limit of detection (LOD) of 1.2 mu M and xanthine recovery of up to 99.3%. The designed sensing system demonstrates the potential for xanthine detection in blood serum samples. The proposed sensor exhibits excellent efficiency due to fast electron transfer and good stability of La2S3 nanorods.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Electrochemical Characterization of Modified Glassy Carbon Electrodes for Non-Enzymatic Glucose Sensors
    Mazurkow, Julia Maria
    Kusior, Anna
    Radecka, Marta
    SENSORS, 2021, 21 (23)
  • [22] Flow Injection Non-Enzymatic Amperometric Detection of Hydrogen Peroxide Based on a Glassy Carbon Electrode Modified with Silver Particles on Glassy Carbon Spherical Powder
    Sirisaeng, Thanaporn
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Limbut, Warakorn
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (03) : B74 - B82
  • [25] Non-enzymatic hydrogen peroxide sensor based on palladium-decorated poly(thionine) modified glassy carbon electrode
    Celebi, Mutlu Sonmez
    Kara, Songul Kirlak
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2024, 71 (05) : 482 - 492
  • [26] A glassy carbon electrode modified with ordered nanoporous Co3O4 for non-enzymatic sensing of glucose
    Zheng, Mingbo
    Li, Lulu
    Gu, Peng
    Lin, Zixia
    Xue, Huaiguo
    Pang, Huan
    MICROCHIMICA ACTA, 2017, 184 (03) : 943 - 949
  • [27] A glassy carbon electrode modified with ordered nanoporous Co3O4 for non-enzymatic sensing of glucose
    Mingbo Zheng
    Lulu Li
    Peng Gu
    Zixia Lin
    Huaiguo Xue
    Huan Pang
    Microchimica Acta, 2017, 184 : 943 - 949
  • [28] Electrochemical evaluation of sulfide mineral modified glassy carbon electrode as novel mediated glucose biosensor
    Wang, Yue
    Zhao, Jifan
    Yang, Tian
    Zhang, Yan
    Tao, Dongping
    Hasebe, Yasushi
    Zhang, Zhiqiang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 894
  • [29] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a nanocomposite made from carbon nanotubes and molybdenum disulfide
    Lin, Yuping
    Chen, Xian
    Lin, Youxiu
    Zhou, Qian
    Tang, Dianping
    MICROCHIMICA ACTA, 2015, 182 (9-10) : 1803 - 1809
  • [30] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a nanocomposite made from carbon nanotubes and molybdenum disulfide
    Yuping Lin
    Xian Chen
    Youxiu Lin
    Qian Zhou
    Dianping Tang
    Microchimica Acta, 2015, 182 : 1803 - 1809