Lanthanum Sulfide Nanorods Modified Glassy Carbon Electrode as Non-Enzymatic Biosensor for Xanthine

被引:1
|
作者
Javeed, Zainab [1 ]
Ibrahim, Muhammad [1 ]
Iqbal, Muhammad Faisal [2 ]
Nawaz, Rahat [3 ]
Hussain, Dilshad [4 ]
Ayub, Muhammad [5 ]
Ashiq, Muhammad Naeem [3 ]
Majeed, Saadat [3 ]
Najam-ul-Haq, Muahmmad [3 ]
Fatima, Batool [1 ]
机构
[1] Bahauddin Zakariya Univ, Dept Biochem, Multan 60800, Pakistan
[2] Zhejiang Normal Univ, Coll Chem & Mat Sci, Jinhua 321004, Peoples R China
[3] Bahauddin Zakariya Univ, Inst Chem Sci, Multan 60800, Pakistan
[4] Univ Karachi, HEJ Res Inst Chem, Int Ctr Chem & Biol Sci, Karachi 75270, Pakistan
[5] Univ Balochistan, Inst Biochem, Quetta, Pakistan
关键词
REDUCED GRAPHENE OXIDE; URIC-ACID; MONITORING XANTHINE; NANOCOMPOSITE; HYPOXANTHINE; SENSOR; HETEROPOLYACIDS; NANOPARTICLES; SERUM;
D O I
10.1149/1945-7111/ad0c69
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Xanthine detection is crucial for the diagnosis of metabolic disorders like xanthinuria and gout. Xanthinuria is due to xanthine stones in the urinary tract. Earlier detection of xanthine levels in human blood can minimize the risks. In this research, a non-enzymatic xanthine sensor is fabricated by depositing different concentrations of lanthanum sulfide nanoparticles on a glassy carbon electrode (GCE). Lanthanum sulfide (La2S3) nanorods are synthesized by a simple hydrothermal method and characterized by X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDS). The effect of pH, scan rates, and xanthine concentration on the peak current is examined. La2S3-modified GCE shows good conductivity, a large surface area, fast electron transfer, and promising sensing capability for xanthine detection. The highest anodic peak for xanthine is observed at a 1 mV s-1 scan rate. The la2S3-based sensor exhibits a limit of detection (LOD) of 1.2 mu M and xanthine recovery of up to 99.3%. The designed sensing system demonstrates the potential for xanthine detection in blood serum samples. The proposed sensor exhibits excellent efficiency due to fast electron transfer and good stability of La2S3 nanorods.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] A non-enzymatic urea sensor based on the nickel sulfide/graphene oxide modified glassy carbon electrode
    Naik, T. S. Sunil Kumar
    Saravanan, S.
    Saravana, K. N. Sri
    Pratiush, Utkarsh
    Ramamurthy, Praveen C.
    MATERIALS CHEMISTRY AND PHYSICS, 2020, 245
  • [2] Non-enzymatic determination of purine nucleotides using a carbon dot modified glassy carbon electrode
    Karthikeyan, R.
    Nelson, D. James
    John, S. Abraham
    ANALYTICAL METHODS, 2019, 11 (30) : 3866 - 3873
  • [3] Gold nanoparticles directly modified glassy carbon electrode for non-enzymatic detection of glucose
    Chang, Gang
    Shu, Honghui
    Ji, Kai
    Oyama, Munetaka
    Liu, Xiong
    He, Yunbin
    APPLIED SURFACE SCIENCE, 2014, 288 : 524 - 529
  • [4] An enzymatic glucose biosensor based on a glassy carbon electrode modified with cylinder-shaped titanium dioxide nanorods
    Yang, Zhanjun
    Xu, Youbao
    Li, Juan
    Jian, Zhiqin
    Yu, Suhua
    Zhang, Yongcai
    Hu, Xiaoya
    Dionysiou, Dionysios D.
    MICROCHIMICA ACTA, 2015, 182 (9-10) : 1841 - 1848
  • [5] An enzymatic glucose biosensor based on a glassy carbon electrode modified with cylinder-shaped titanium dioxide nanorods
    Zhanjun Yang
    Youbao Xu
    Juan Li
    Zhiqin Jian
    Suhua Yu
    Yongcai Zhang
    Xiaoya Hu
    Dionysios D. Dionysiou
    Microchimica Acta, 2015, 182 : 1841 - 1848
  • [6] Non-enzymatic Sensing of Glucose Using Glassy Carbon Electrode Modified with Organometallic Complex of Nickel
    Ciszewski, Aleksander
    Stepniak, Izabela
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (10): : 8298 - 8307
  • [7] A novel enzymatic glucose biosensor and sensitive non-enzymatic hydrogen peroxide sensor based on graphene and cobalt oxide nanoparticles composite modified glassy carbon electrode
    Karuppiah, Chelladurai
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Veeramani, Vediyappan
    Periakaruppan, Prakash
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 196 : 450 - 456
  • [8] Non-Enzymatic Amperometric Determination of Glucose by CuO Nanobelt Graphene Composite Modified Glassy Carbon Electrode
    Muralikrishna, Sreeramareddygari
    Sureshkumar, Kempahanumakkagari
    Yan, Zhou
    Fernandez, Carlos
    Ramakrishnappa, Thippeswamy
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2015, 26 (08) : 1632 - 1641
  • [9] A novel green synthesized NiO nanoparticles modified glassy carbon electrode for non-enzymatic glucose sensing
    Youcef, Messai
    Hamza, Bezzi
    Nora, Hellal
    Walid, Belbacha
    Salima, Messali
    Ahmed, Belghidoum
    Malika, Foudia
    Marc, Schmutz
    Christian, Blanck
    Wassila, Derafa
    Eddine, Mekki Djamel
    Larbi, Zerroual
    MICROCHEMICAL JOURNAL, 2022, 178
  • [10] Progress of Enzymatic and Non-Enzymatic Electrochemical Glucose Biosensor Based on Nanomaterial-Modified Electrode
    Nor, Noorhashimah Mohamad
    Ridhuan, Nur Syafinaz
    Razak, Khairunisak Abdul
    BIOSENSORS-BASEL, 2022, 12 (12):