Substantiating and Adopting Lung Ultrasound Scores to Predict Surfactant Need in Preterm Neonates with Respiratory Distress Syndrome within an Institution

被引:0
|
作者
Chan, Belinda [1 ,2 ]
Torsitano, Christopher
Gordon, Sasha
Konana, Olive
Singh, Yogen
机构
[1] Univ Utah, Dept Pediat, Neonatol Div, 295 Chipeta Way, Salt Lake City, UT 84108 USA
[2] Univ Utah, Dept Radiol & Imaging Sci, Salt Lake City, UT 84108 USA
关键词
point of care ultrasound; lung ultrasound; lung ultrasound scores; preterm neonates; respiratory distress syndrome; surfactant;
D O I
10.1055/s-0044-1779500
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective Administering surfactant timely and appropriately is important to minimize lung injury but remains challenging in preterm neonates with respiratory distress syndrome. The published literature supports that lung ultrasound (LUS) score can predict surfactant need. Neonatal LUS scanning specification and parameter setting guidelines have been recently published for standardization. However, variations in scanning protocols and machine settings hinder its clinical implementation widely. This observational study aims to internally validate the suggested LUS protocol in a neonatal intensive care unit to establish a correlation between LUS scores and surfactant need as the first step of integrating LUS in the clinical practice. Study Design LUS was performed on 40 eligible preterm neonates within 3 hours after birth or before surfactant administration between May 2020 and March 2021. The neonates were between 27 and 32 weeks' gestational age, and all had respiratory distress. Neonates with known congenital anomalies were excluded. A high-frequency linear probe was used to obtain LUS images from six lung zones which were scored using a 0 to 3 system, yielding a maximum of 18 points. Treating physicians were blinded to the LUS score. Receiver operating characteristic analysis determined the optimal LUS score cutoff for predicting surfactant need. Results Fifteen of the 40 neonates (38%) required higher oxygen fraction and received surfactant. In our cohort, an LUS score >= 10 was identified as the optimal cutoff for predicting surfactant need, with a sensitivity of 80% and specificity of 84%. The area under the curve was 0.8 ( p = 0.0003). LUS predicted surfactant need at a median of 3.5 hours earlier than traditional clinical decision ( p < 0.0037). Conclusion LUS is a helpful adjunct for predicting surfactant need in preterm neonates. This study describes an approach to implement the LUS protocol and score for clinical decision-making in the clinical practice. Key Points LUS is a helpful adjunct for predicting surfactant need in preterm neonates. Machine setting variation and probe selection may affect LUS image and score. LUS score should be validated at the local unit before clinical implementation.
引用
收藏
页码:1652 / 1659
页数:8
相关论文
共 37 条
  • [1] The Role of Lung Ultrasound as an Early Diagnostic Tool for Need of Surfactant Therapy in Preterm Infants with Respiratory Distress Syndrome
    Vardar, Gonca
    Karadag, Nilgun
    Karatekin, Guner
    AMERICAN JOURNAL OF PERINATOLOGY, 2021, 38 (14) : 1547 - 1556
  • [2] Does lung ultrasound score predict the need for surfactant in extremely preterm neonates?
    Shafer, Grant J.
    Suresh, Gautham K.
    ACTA PAEDIATRICA, 2019, 108 (05) : 973 - 973
  • [3] Surfactant administration in preterm neonates with Respiratory Distress Syndrome: LISA versus INSURE
    Aldeia Da Silva, Rita
    Araujo, Veronica
    Pereira, Mariana
    Machado, Clara
    Raposo, Filipa
    CRITICAL PUBLIC HEALTH, 2024, 34 (01) : 15 - 16
  • [4] The Role of Lung Ultrasonography Scoring in Predicting the Need for Surfactant Therapy in Neonates, With Respiratory Distress Syndrome
    Nosrati, Maryam
    Akhoundi, Neda
    Nanva, Amir Hasan Ahmadzadeh
    Siami, Alireza
    Shariati, Maryam Khoshnoud
    Rezazadeh, Elmira
    Pouya, Ensi Khalili
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2023, 39 (04) : 348 - 354
  • [5] Progress in the Application of Lung Ultrasound for the Evaluation of Neonates with Respiratory Distress Syndrome
    Bao, Ling-Yun
    Dao, Xin-Yue
    Du, Kun
    JOURNAL OF MULTIDISCIPLINARY HEALTHCARE, 2024, 17 : 1 - 9
  • [6] Surfactant status in preterm Neonates recovering from respiratory distress syndrome
    Verlato, Giovanna
    Cogo, Paola Elisa
    Balzani, Marco
    Gucciardi, Antonina
    Burattini, Ilaria
    De Benedictis, Fernando
    Martiri, Giovanna
    Carnielli, Virgilio Paolo
    PEDIATRICS, 2008, 122 (01) : 102 - 108
  • [7] Lung Ultrasound Score to Predict Surfactant Administration in Premature Neonates with Respiratory Distress Syndrome: A Systematic Review and Meta-analysis
    Xie, Mengke
    Deng, Biying
    Li, Song
    IRANIAN JOURNAL OF PEDIATRICS, 2023, 33 (04)
  • [8] A Refined Score, Namely Thoracic Ultrasound Score, to Predict the Need for Surfactant in Preterm Neonates: A Prospective, Multicenter, Observational Study
    Forcellini, Carlo Alberto
    Rossignoli, Sara
    Ficial, Benjamim
    Cenci, Giorgia
    Santoro, Leonardo
    Bonadies, Luca
    Franchetti, Enrico
    Vallortigara, Francesca
    Mardegan, Veronica
    Vecchiato, Luca
    Scollo, Massimo
    Zanetto, Lorenzo
    Vedovato, Stefania
    Tsatsaris, Nicola
    Cattarossi, Luigi
    Beghini, Renzo
    Pietrobelli, Angelo
    PEDIATRIC PULMONOLOGY, 2025, 60 (02)
  • [9] Budesonide and Surfactant Combination for Treatment of Respiratory Distress Syndrome in Preterm Neonates and Evaluation Outcomes
    Safa, Fatemeh Baghal
    Noorishadkam, Mahmood
    Lookzadeh, Mohamad Hosein
    Mirjalili, Seyed Reza
    Ekraminasab, Sedigheh
    JOURNAL OF CLINICAL NEONATOLOGY, 2023, 12 (04) : 135 - 141
  • [10] Lung recruitment improves the efficacy of intubation-surfactant-extubation treatment for respiratory distress syndrome in preterm neonates, a randomized controlled trial
    Yong Yang
    Wenkang Yan
    Minyi Ruan
    Lan Zhang
    Jinzhen Su
    Haohui Deng
    Minxu Li
    BMC Pediatrics, 22