Evaluation of Virtual Reality Perimetry and Standard Automated Perimetry in Normal Children

被引:20
作者
Groth, Sylvia L. [1 ,4 ]
Linton, Edward F. [1 ,2 ]
Brown, Eric N. [1 ]
Makadia, Frini [1 ,3 ]
Donahue, Sean P. [1 ]
机构
[1] Vanderbilt Univ, Dept Ophthalmol & Visual Sci, Med Ctr, Nashville, TN USA
[2] Univ Iowa, Dept Ophthalmol & Visual Sci, Iowa City, IA USA
[3] Wheaton Eye Clin, Wheaton, IL USA
[4] 2311 Pierce Ave, Nashville, TN 37232 USA
关键词
automated perimetry; pediatrics; virtual reality perimetry; visual field; RELIABILITY; FEASIBILITY; STRATEGY; TESTS; SITA;
D O I
10.1167/tvst.12.1.6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The Olleyes VisuALL-K is a pediatric videogame-based static threshold perime-ter using a virtual reality headset. We determined normal threshold sensitivities for the 24-2 test locations using the virtual reality perimetry (VRP) and also tested patients on the Humphrey Field Analyzer (HFA). Patient satisfaction for the two instruments was compared.Methods: This exploratory study tested 50 normal pediatric participants aged 8 to 17 years on the HFA and VRP. The main outcome measure was threshold sensitivity at the 24-2 test locations for the two instruments.Results: The mean participant age was 13.0 & PLUSMN;2.6 years; 50% were female. The threshold values for VRP are reported as measured on the device and after conversion to an HFA-equivalent scale. Age-adjusted thresholds showed a mean sensitivity of 31.8 & PLUSMN; 1.1 dB (46.1 & PLUSMN; dB HFA equivalent) diminution from the maximum light intensity in the VRP and 31.0 & PLUSMN; 1.5 dB diminution from the maximum light intensity in the HFA; interparticipant variability in mean threshold sensitivity was 2.7 & PLUSMN; 0.4 dB for the VRP and 2.7 & PLUSMN; 0.6 dB for the HFA. The HFA demonstrated decreased threshold sensitivity with increasing eccen-tricity, whereas the VRP threshold did not seem to vary with eccentricity. Mild age effects on threshold sensitivity were seen in the VRP and the HFA (R2 = 0.11, P < 0.001 and R2 = 0.05, P < 0.05, respectively). The mean time to completion for VRP and HFA was 7.6 & PLUSMN; 1.5 and 5.3 & PLUSMN; 0.9 min/eye, respectively (P < 0.0001). Patient satisfaction scores favored VRP (P < 0.01) despite the longer test duration.Conclusions: The Olleyes game-based VRP and HFA can be used to map out the periph-eral vision in normal children. The VRP has a higher patient satisfaction when used in children than the HFA. The portability of the test allows it to be performed in a myriad of environments, lending a flexibility that can benefit this population. Translational Relevance: This virtual reality perimetry device provides an alternative to the Humphrey Field Analyzer for children.
引用
收藏
页数:10
相关论文
共 26 条
[1]   Assessment of an effective visual field testing strategy for a normal pediatric population [J].
Akar, Yusuf ;
Yilmaz, Aygen ;
Yucel, Iclal .
OPHTHALMOLOGICA, 2008, 222 (05) :329-333
[2]  
Anderson D.R., 1999, Automated static perimetry, V2nd
[3]  
Bengtsson B, 1997, ACTA OPHTHALMOL SCAN, V75, P368
[4]   Evaluation of a new threshold visual field strategy, SITA, in normal subjects [J].
Bengtsson, B ;
Heijl, A ;
Olsson, J .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 (02) :165-169
[5]   Retinal NFL thinning on OCT correlates with visual field loss in pediatric craniopharyngioma [J].
Bialer, Omer Y. ;
Goldenberg-Cohen, Nitza ;
Toledano, Helen ;
Snir, Moshe ;
Michowiz, Shalom .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2013, 48 (06) :494-499
[6]   The reliability of frequency-doubling perimetry in young children [J].
Blumenthal, EZ ;
Haddad, A ;
Horani, A ;
Anteby, I .
OPHTHALMOLOGY, 2004, 111 (03) :435-439
[7]   Quantification of gaze reaction time in infants with Pediatric Perimeter [J].
Datta, Sourav ;
Chilakala, Koteswararao ;
Vempati, Sandeep ;
Oleti, Tejopratap ;
Kulkarni, Jaishree ;
Murki, Srinivas ;
Gaddam, Pramod ;
Satgunam, PremNandhini .
PLOS ONE, 2021, 16 (09)
[8]   SITA visual field testing in children [J].
Donahue, SP ;
Porter, A .
JOURNAL OF AAPOS, 2001, 5 (02) :114-117
[9]   Findings from an opt-in eye examination service in English special schools. Is vision screening effective for this population? [J].
Donaldson, Lisa A. ;
Karas, Marek ;
O'Brien, Donna ;
Woodhouse, J. Margaret .
PLOS ONE, 2019, 14 (03)
[10]   Assessment of Patient Opinions of Different Clinical Tests Used in the Management of Glaucoma [J].
Gardiner, Stuart K. ;
Demirel, Shaban .
OPHTHALMOLOGY, 2008, 115 (12) :2127-2131