Comparative Study Between Non-Diffractive Extended Depth of Focus and Monofocal Intraocular Lenses

被引:3
作者
Kandavel, Rom [1 ,3 ]
Colvard, Michael [1 ]
Dredge, Justin [1 ]
Bayle, Michael [1 ]
Alam, Tamanna [1 ]
Snyder, James [1 ]
Hall, Brad [2 ]
机构
[1] Colvard Kandavel Eye Ctr, Encino, CA 91316 USA
[2] Sengi, Penniac, NB E3A 8X8, Canada
[3] Colvard Kandavel Eye Ctr, 5363 Balboa Blvd,Suite 540, Encino, CA 91316 USA
关键词
EDOF IOL; cataract surgery; Vivity; monofocal; OUTCOMES; RANGE;
D O I
10.2147/OPTH.S402069
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the visual acuity and quality of vision in bilaterally implanted ZCBOO/ZCTx monofocal (Johnson & Johnson Vision) intraocular lens (IOL) and bilaterally implanted DATx15 extended depth of focus (EDOF) IOL (Alcon Vision, LLC). Methods: A single site, non-interventional study comparing ZCBOO/ZCTx monofocal IOL patients implanted with DATx15 IOL toric or non-toric versions in both eyes. A total of 30 patients (60 eyes) completed the study in the monofocal group, 32 (64 eyes) in the EDOF group, and all were targeted for emmetropia. Binocular uncorrected distance, intermediate (66cm), and near (40cm) visual acuities and distance corrected distance, intermediate (66cm) and near (40cm) visual acuities were assessed. Binocular distance corrected defocus curve testing was from -3.5 D to +3 D. Patient reported visual disturbances (QUVID) and IOL satisfaction (IOLSAT) questionnaires were administered. Results: The DATx15 group mean uncorrected visual acuity was 0.15 +/- 0.10 logMAR at 66cm and 0.36 +/- 0.14 logMAR at 40cm, compared to 0.24 +/- 0.15 logMAR and 0.59 +/- 0.17 logMAR respectively for the ZCBOO/ZCTx group. The DATx15 group (23 respondents, 74%) also reported significantly more spectacle independence at near with the IOLSAT (p < 0.01), compared to the ZCBOO/ZCTx group (13 respondents, 43%). Glare, halos, starbursts, and blur reported on the QUVID questionnaire were similar in the two groups. Conclusion: The DATx15 group had improved near and intermediate vision and increased spectacle independence compared to the ZCBOO/ZCTx group.
引用
收藏
页码:1161 / 1168
页数:8
相关论文
共 50 条
[31]   Extended depth-of-focus technology in intraocular lenses [J].
Kohnen, Thomas ;
Suryakumar, Rajaraman .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (02) :298-304
[32]   Difference in Quality of Vision Outcome among Extended Depth of Focus, Bifocal, and Monofocal Intraocular Lens Implantation [J].
Chao, Chen-Cheng ;
Lin, Hung-Yuan ;
Lee, Chia-Yi ;
Mai, Elsa Lin-Chin ;
Lian, Ie-Bin ;
Chang, Chao-Kai .
HEALTHCARE, 2022, 10 (06)
[33]   Clinical Results of Diffractive, Refractive, Hybrid Multifocal, and Monofocal Intraocular Lenses [J].
Dyrda, Agnieszka ;
Martinez-Palmer, Ana ;
Martin-Moral, Daniel ;
Rey, Amanda ;
Morilla, Antonio ;
Castilla-Marti, Miguel ;
Arones-Santivanez, Janny .
JOURNAL OF OPHTHALMOLOGY, 2018, 2018
[34]   A comparative study of the visual outcomes between a new trifocal and an extended depth of focus intraocular lens [J].
Ruiz-Mesa, Ramon ;
Abengozar-Vela, Antonio ;
Ruiz-Santos, Maria .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (02) :182-187
[35]   Comparative Evaluation of Visual Performance and Patient Satisfaction following Cataract Surgery: A Retrospective Analysis of an Extended Depth-of-Focus Intraocular Lens and a Diffractive Multifocal Lens with Extended Depth of Focus [J].
Han, Kwang Eon ;
Lee, Ji Eun ;
Mizota, Atsushi .
JOURNAL OF CLINICAL MEDICINE, 2023, 12 (23)
[36]   Visual outcomes following bilateral implantation of a non-diffractive extended depth of focus toric intraocular lens using a mini-monovision approach [J].
Lee, Mun Wai .
INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
[37]   Clinical Performance and Optical Quality of a Non-Diffractive Extended-Depth-of-Focus Intraocular Lens in Patients Undergoing Cataract Surgery or Refractive Lensectomy [J].
Cano-Ortiz, Antonio ;
Sanchez-Ventosa, Alvaro ;
Gonzalez-Cruces, Timoteo ;
Villalba-Gonzalez, Marta ;
Aguilar-Salazar, Francisco Javier ;
Prados-Carmona, Juan J. ;
Diaz-Mesa, Vanesa ;
Villarrubia, Alberto .
JOURNAL OF CLINICAL MEDICINE, 2025, 14 (11)
[38]   Influence of extended depth of focus intraocular lenses on visual field sensitivity [J].
Takahashi, Makiko ;
Yamashiro, Chiemi ;
Yoshimoto, Takuya ;
Kobayashi, Yuka ;
Higashijima, Fumiaki ;
Kobayashi, Masaaki ;
Hatano, Makoto ;
Ohta, Manami ;
Nagai, Tomohiko ;
Teranishi, Shinichiro ;
Suzuki, Katsuyoshi ;
Takabatake, Ryu ;
Kimura, Kazuhiro .
PLOS ONE, 2020, 15 (09)
[39]   Extended depth-of-focus intraocular lenses: power calculation and outcomes [J].
Coassin, Marco ;
Di Zazzo, Antonio ;
Antonini, Marco ;
Gaudenzi, Daniele ;
Gallo Afflitto, Gabriele ;
Kohnen, Thomas .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (11) :1554-1560
[40]   Measuring Defocus Curves of Monofocal, Multifocal and Extended Depth-of-focus Intraocular Lenses Using Optical Bench Test [J].
Koo, Yong Ho ;
Lee, Chang Su ;
Kim, Jin Soo ;
Shin, Min Chul ;
Kim, Eun Chul ;
Kim, Man Soo ;
Hwang, Ho Sik .
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (02) :153-158