Uncertainty quantification in DenseNet model using myocardial infarction ECG signals

被引:32
作者
Jahmunah, V. [1 ]
Ng, E. Y. K. [1 ]
Tan, Ru-San [2 ]
Oh, Shu Lih [3 ]
Acharya, U. Rajendra [3 ,4 ,5 ,6 ,7 ,8 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore, Singapore
[2] Natl Heart Ctr, Singapore, Singapore
[3] Ngee Ann Polytech, Sch Engn, Singapore, Singapore
[4] Singapore Univ Social Sci, Sch Social Sci & Technol, Biomed Engn, Singapore, Singapore
[5] Kumamoto Univ, Int Res Org Adv Sci & Technol IROAST, Kumamotov, Japan
[6] Asia Univ, Dept Bioinformat & Med Engn, Taichung, Taiwan
[7] Univ Southern Queensland, Sch Management & Enterprise, Darling Ht, QLD, Australia
[8] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
关键词
Uncertainty quantification; Myocardial infarction; DenseNet model; Deep learning; Predictive entropy; Reverse KL divergence; MORTALITY; FUSION;
D O I
10.1016/j.cmpb.2022.107308
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: Myocardial infarction (MI) is a life-threatening condition diagnosed acutely on the electrocardiogram (ECG). Several errors, such as noise, can impair the prediction of automated ECG diagnosis. Therefore, quantification and communication of model uncertainty are essential for reliable MI diagnosis.Methods: A Dirichlet DenseNet model that could analyze out-of-distribution data and detect misclassi-fication of MI and normal ECG signals was developed. The DenseNet model was first trained with the pre-processed MI ECG signals (from the best lead V6) acquired from the Physikalisch-Technische Bun-desanstalt (PTB) database, using the reverse Kullback-Leibler (KL) divergence loss. The model was then tested with newly synthesized ECG signals with added em and ma noise samples. Predictive entropy was used as an uncertainty measure to determine the misclassification of normal and MI signals. Model per-formance was evaluated using four uncertainty metrics: uncertainty sensitivity (UNSE), uncertainty speci-ficity (UNSP), uncertainty accuracy (UNAC), and uncertainty precision (UNPR); the classification threshold was set at 0.3.Results: The UNSE of the DenseNet model was low but increased over the studied decremental noise range (-6 to 24 dB), indicating that the model grew more confident in classifying the signals as they got less noisy. The model became more certain in its predictions from SNR values of 12 dB and 18 dB onwards, yielding UNAC values of 80% and 82.4% for em and ma noise signals, respectively. UNSP and UNPR values were close to 100% for em and ma noise signals, indicating that the model was self-aware of what it knew and didn't. Conclusion: Through this work, it has been established that the model is reliable as it was able to convey when it was not confident in the diagnostic information it was presenting. Thus, the model is trustworthy and can be used in healthcare applications, such as the emergency diagnosis of MI on ECGs.(c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Automated characterization and classification of coronary artery disease and myocardial infarction by decomposition of ECG signals: A comparative study
    Acharya, U. Rajendra
    Fujita, Hamido
    Adam, Muhammad
    Lih, Oh Shu
    Sudarshan, Vidya K.
    Hong, Tan Jen
    Koh, Joel E. W.
    Hagiwara, Yuki
    Chua, Chua K.
    Poo, Chua Kok
    San, Tan Ru
    INFORMATION SCIENCES, 2017, 377 : 17 - 29
  • [22] Detection of myocardial infarction in 12 lead ECG using support vector machine
    Dohare, Ashok Kumar
    Kumar, Vinod
    Kumar, Ritesh
    APPLIED SOFT COMPUTING, 2018, 64 : 138 - 147
  • [23] Takotsubo cardiomyopathy in India and its electrocardiography (ECG) comparison to myocardial infarction
    Mishra, Tanisha
    Saha, Rijushree
    Paramasivam, Ganesh
    EGYPTIAN HEART JOURNAL, 2024, 76 (01)
  • [24] A Novel Approach Using Voting from ECG Leads to Detect Myocardial Infarction
    Lodhi, Awais M.
    Qureshi, Adnan N.
    Sharif, Usman
    Ashiq, Zahid
    INTELLIGENT SYSTEMS AND APPLICATIONS, INTELLISYS, VOL 2, 2019, 869 : 337 - 352
  • [25] Detection of Myocardial Infarction Using ECG and Multi-Scale Feature Concatenate
    Jian, Jia-Zheng
    Ger, Tzong-Rong
    Lai, Han-Hua
    Ku, Chi-Ming
    Chen, Chiung-An
    Abu, Patricia Angela R.
    Chen, Shih-Lun
    SENSORS, 2021, 21 (05) : 1 - 17
  • [26] Differential urinary proteomics analysis of myocardial infarction using iTRAQ quantification
    Zou, Lili
    Wang, Xubo
    Guo, Zhengguang
    Sun, Haidan
    Shao, Chen
    Yang, Yehong
    Sun, Wei
    MOLECULAR MEDICINE REPORTS, 2019, 19 (05) : 3972 - 3988
  • [27] Uncertainty quantification of the pressure waveform using a Windkessel model
    Keramat, Alireza
    Flores-Geronimo, Joaquin
    Alastruey, Jordi
    Zhang, Yuanting
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024, 40 (12)
  • [28] Intelligent System based on Genetic Algorithm and Support Vector Machine for Detection of Myocardial Infarction from ECG signals
    Diker, Aykut
    Comert, Zafer
    Avci, Engin
    Velappan, Subha
    2018 26TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2018,
  • [29] Epileptic Seizure Prediction from EEG Signals Using DenseNet
    Jana, Ranjan
    Bhattacharyya, Siddhartha
    Das, Swagatam
    2019 IEEE SYMPOSIUM SERIES ON COMPUTATIONAL INTELLIGENCE (IEEE SSCI 2019), 2019, : 604 - 609
  • [30] ECG sonification to support the diagnosis and monitoring of myocardial infarction
    Andrea Lorena Aldana Blanco
    Steffen Grautoff
    Thomas Hermann