Interaction among Multiple Electric Vehicle Chargers: Measurements on Harmonics and Power Quality Issues

被引:6
作者
Mazza, Andrea [1 ]
Benedetto, Giorgio [1 ]
Bompard, Ettore [1 ]
Nobile, Claudia [1 ]
Pons, Enrico [1 ]
Tosco, Paolo [2 ]
Zampolli, Marco [2 ]
Jaboeuf, Remi [2 ]
机构
[1] Politecn Torino, Dipartimento Energia Galileo Ferraris, I-10129 Turin, Italy
[2] Edison SpA, I-20121 Milan, Italy
关键词
electric vehicles (EVs); vehicle-to-grid (V2G); EV charging stations (EVCSs); harmonics; power quality; IMPACT;
D O I
10.3390/en16207051
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The electric vehicle (EV) market is growing rapidly due to the necessity of shifting from fossil fuel-based mobility to a more sustainable one. Smart charging paradigms (such as vehicle-to-grid (V2G), vehicle-to-building (V2B), and vehicle-to-home (V2H)) are currently under development, and the existing implementations already enable a bidirectional energy flow between the vehicles and the other systems (grid, buildings, or home appliances, respectively). With regard to grid connection, the increasingly higher penetration of electric vehicles must be carefully analyzed in terms of negative impacts on the power quality; and hence, the effects of electric vehicle charging stations (EVCSs) must be considered. In this work, the interactions of multiple electric vehicle charging stations have been studied through laboratory experiments. Two identical bidirectional DC chargers, with a rated power of 11 kW each, have been supplied by the same voltage source, and the summation phenomenon of the current harmonics of the two chargers (which leads to an amplification of their values) has been analyzed. The experiment consisted of 100 trials, which considered four different combinations of power set-points in order to identify the distribution of values and to find suitable indicators for understanding the trend of the harmonic interaction. By studying the statistical distribution of the Harmonic Summation Index, defined in the paper, the impact of the harmonic distortion caused by the simultaneous charging of multiple electric vehicles has been explored. Based on this study, it can be concluded that the harmonic contributions of the electric vehicle charging stations tend to add up with increasing degrees of similarity of the power set-points, while they tend to cancel out the more the power set-points differ among the chargers.
引用
收藏
页数:17
相关论文
共 27 条
  • [1] Alghsoon E, 2017, INT RENEW ENERG CONG
  • [2] [Anonymous], 2022, IEEE Std 519-2022 (Revision of IEEE Std 519-2014), P1, DOI DOI 10.1109/IEEESTD.2022.9848440
  • [3] [Anonymous], 2014, 5192014 IEEE, P1
  • [4] [Anonymous], 2022, EN Standard 50160
  • [5] [Anonymous], 2015, Electromagnetic compatibility (EMC) part 4-30, testing and measurement techniques-power quality measurement methods
  • [6] [Anonymous], 2019, 4Q POWER AMPLIFIER PCU-3x7000-AC/DC-400V-54A-4G with Different Options-User Manual
  • [7] [Anonymous], 2017, Fast Charging Diversity Impact on Total Harmonic Distortion Due to Phase Cancellation Effect: Fast Charger's Testing Experimental Results
  • [8] [Anonymous], 2023, TR 61000-1-1
  • [9] Impact of EV Charger Load on Distribution Network Capacity: A Case Study in Toronto
    Awadallah, Mohamed A.
    Singh, Birendra N.
    Venkatesh, Bala
    [J]. CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2016, 39 (04): : 268 - 273
  • [10] Electric Mobility: An Overview of the Main Aspects Related to the Smart Grid
    Barreto, Ruben
    Faria, Pedro
    Vale, Zita
    [J]. ELECTRONICS, 2022, 11 (09)