Robot-assisted S2 screw fixation for posterior pelvic ring injury

被引:8
作者
Wang, Junqiang [1 ]
Zhang, Teng [2 ,3 ]
Han, Wei [1 ]
Hua, Kehan [1 ]
Wu, Xinbao [1 ]
机构
[1] Beijing Jishuitan Hosp, Dept Orthoped Trauma, Beijing 100035, Peoples R China
[2] TINAVI Med Technol Co Ltd, Beijing 100192, Peoples R China
[3] Tsinghua Univ, Sch Med, Beijing 100085, Peoples R China
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2023年 / 54卷
关键词
Pelvic injuries; Robotics; Sacroiliac screw; SACROILIAC SCREWS; ILIOSACRAL SCREWS; QUANTIFICATION; PLACEMENT; KINDS;
D O I
10.1016/j.injury.2020.11.044
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Percutaneous sacroiliac screw is one of the main methods to treat unstable posterior pelvic ring injury. However, complexity of pelvic anatomical structure increases the difficulty and risk with freehand operation. Besides, S2 screw fixation began to receive attention. The purpose of the current study was to evaluate the safety, accuracy, efficiency and clinical outcome of robot-assisted S2 screw fixation for posterior pelvic ring injury. Methods: We reviewed 128 cases of unstable posterior pelvic ring injury treated by percutaneous sacroiliac screw fixation in our hospital from January 2016 to January 2020. All cases were divided into robotassisted S1 group (RAS1), robot-assisted S2 group (RAS2), freehand group S1 group (FHS1) and freehand group S2 group (FHS2). The mean times of fluoroscopy per screw and adjustment per guide wire were used to evaluate radiation exposure and the efficiency of screw placement, respectively. The final position of the screw was evaluated with postoperative CT to illustrate security and accuracy. 108 patients (84.38%) were followed up for 5 similar to 24 months and the Majeed scores were compared among groups. Results: A total of 180 screws were inserted. In comparison of the mean times of fluoroscopy per screw and adjustment per guide wire, RA group was significant less than FH group, further comparison revealed that freehand S2 placement need more fluoroscopy and adjustment times compared with freehand S1 placement, but for robot-assisted procedure, there was no difference between placing S1 and S2. Screw penetration was found in the FHS1(3/48) and FHS2(2/14) and none in RAS1 or RAS2, which means robotassisted groups were more safety and accurate (P<0.001). The mean Majeed score in RAS1 (83.33 +/- 13.47) and RAS2 (82.32 +/- 11.42) was higher than in FHS1 (80.43 +/- 12.25) and FHS2 (75.08 +/- 18.47), but this difference failed to reach significant. Conclusion: Compared with the freehand operation, TiRobot increased the safety and accuracy, reduced radiation exposure, and improved the efficiency. TiRobot could reduce the risk of S2 placement and provide a safe and feasible way for clinical practice. (c) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S3 / S7
页数:5
相关论文
共 18 条
[1]   Safe placement of S1 and S2 iliosacral screws:: The "vestibule" concept [J].
Carlson, DA ;
Scheid, DK ;
Maar, DC ;
Baele, JR ;
Kaehr, DM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (04) :264-269
[2]   Radiographic Quantification and Analysis of Dysmorphic Upper Sacral Osseous Anatomy and Associated Iliosacral Screw Insertions [J].
Conflitti, Joseph M. ;
Graves, Matt L. ;
Routt, M. L. Chip, Jr. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (10) :630-636
[3]   Comparison of the risk of breakage of two kinds of sacroiliac screws in the treatment of bilateral sacral fractures [J].
Fu, Shengqiang ;
Zhao, Yong ;
Lian, Wei ;
Zou, Dexin ;
Sun, Tao ;
Zhao, Yuchi ;
Tan, Jiangwei ;
Zhang, Shudong ;
Wang, Dan .
EUROPEAN SPINE JOURNAL, 2014, 23 (07) :1558-1567
[4]   Transiliac-Transsacral Screws for Posterior Pelvic Stabilization [J].
Gardner, Michael J. ;
Routt, M. L. Chip, Jr. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (06) :378-384
[5]   Quantification of the Upper and Second Sacral Segment Safe Zones in Normal and Dysmorphic Sacra [J].
Gardner, Michael J. ;
Morshed, Saam ;
Nork, Sean E. ;
Ricci, William M. ;
Routt, Milton L. Chip, Jr. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (10) :622-629
[6]   2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series [J].
Gras, Florian ;
Marintschev, Ivan ;
Wilharm, Arne ;
Klos, Kajetan ;
Mueckley, Thomas ;
Hofmann, Gunther O. .
BMC MUSCULOSKELETAL DISORDERS, 2010, 11
[7]   Evaluation of a Bi-Planar Robot Navigation System for Insertion of Cannulated Screws in Femoral Neck Fractures [J].
He, Meng ;
Han, Wei ;
Zhao, Chun-peng ;
Su, Yong-gang ;
Zhou, Li ;
Wu, Xin-bao ;
Wang, Jun-qiang .
ORTHOPAEDIC SURGERY, 2019, 11 (03) :373-379
[8]  
Hinsche AF, 2002, CLIN ORTHOP RELAT R, P135
[9]   Variations in Sacral Morphology and Implications for Iliosacral Screw Fixation [J].
Miller, Anna N. ;
Routt, Milton L. Chip, Jr. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2012, 20 (01) :8-16
[10]   Posterior screw fixation in rotationally unstable pelvic ring injuries [J].
Osterhoff, Georg ;
Ossendorf, Christian ;
Wanner, Guido A. ;
Simmen, Hans-Peter ;
Werner, Clement M. L. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (10) :992-996