A Novel Muscle Innervation Zone Estimation Method Using Monopolar High Density Surface Electromyography

被引:1
|
作者
Huang, Chengjun [1 ]
Chen, Maoqi [2 ]
Zhang, Yingchun [3 ]
Li, Sheng [4 ]
Klein, Cliff S. [5 ]
Zhou, Ping [2 ]
机构
[1] Baylor Coll Med, Dept Neurosci, Houston, TX 77030 USA
[2] Univ Hlth & Rehabil Sci, Sch Rehabil Sci & Engn, Qingdao 200027, Shandong, Peoples R China
[3] Univ Houston, Dept Biomed Engn, Houston, TX 77024 USA
[4] Univ Texas Hlth Sci Ctr Houston, TIRR Mem Hermann Hosp, Dept Phys Med & Rehabil, Houston, TX 77030 USA
[5] Guangdong Work Injury Rehabil Ctr, Guangzhou 510645, Guangdong, Peoples R China
关键词
High density surface electromyography (EMG); innervation zone (IZ); principal component analysis (PCA); the 2nd principal component; PRINCIPAL COMPONENT ANALYSIS; FIBER CONDUCTION-VELOCITY; MOTOR UNITS; EMG; POSITION; LOCALIZATION; ORGANIZATION; ACTIVATION; SIGNALS; MATRIX;
D O I
10.1109/TNSRE.2022.3215612
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study presents a novel method to estimate a muscle's innervation zone (IZ) location from monopolar high density surface electromyography (EMG) signals. Based on the fact that 2nd principal component coefficients derived from principal component analysis (PCA) are linearly related with the time delay of different channels, the channels located near the IZ should have the shortest time delays. Accordingly, we applied a novel method to estimate a muscle's IZ based on PCA. The performance of the developed method was evaluated by both simulation and experimental approaches. The method based on 2nd principal component of monopolar high density surface EMG achieved a comparable performance to cross-correlation analysis of bipolar signals when noise was simulated to be independently distributed across all channels. However, in simulated conditions of specific channel contamination, the PCA based method achieved superior performance than the cross-correlation method. Experimental high density surface EMG was recorded from the bicepsbrachii of 9 healthysubjects during maximum voluntary contractions. The PCA and cross-correlation based methods achieved high agreement, with a difference in IZ location of 0.47 +/- 0.4 IED (inter-electrode distance = 8 mm). The results indicate that analysis of 2nd principal component coefficients provides a useful approach for IZ estimation using monopolar high density surface EMG.
引用
收藏
页码:22 / 30
页数:9
相关论文
共 50 条
  • [1] Muscle innervation zone estimation from monopolar high-density M-waves using principal component analysis and radon transform
    Huang, Chengjun
    Lu, Zhiyuan
    Chen, Maoqi
    Klein, Cliff S. S.
    Zhang, Yingchun
    Li, Sheng
    Zhou, Ping
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [2] Biceps Brachii Muscle Innervation Zone Location in Healthy Subjects Using High-Density Surface Electromyography
    Guzman, Rodrigo A.
    Silvestre, Rony A.
    Arriagada, David A.
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2011, 29 (02): : 347 - 352
  • [3] Global Innervation Zone Identification With High-Density Surface Electromyography
    Zhang, Chuan
    Dias, Nicholas
    He, Jinbao
    Zhou, Ping
    Li, Sheng
    Zhang, Yingchun
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (03) : 718 - 725
  • [4] Neurophysiological Factors Affecting Muscle Innervation Zone Estimation Using Surface EMG: A Simulation Study
    Huang, Chengjun
    Chen, Maoqi
    Li, Xiaoyan
    Zhang, Yingchun
    Li, Sheng
    Zhou, Ping
    BIOSENSORS-BASEL, 2021, 11 (10):
  • [5] Transcutaneous innervation zone imaging from high-density surface electromyography recordings
    Liu, Yang
    Zhang, Chuan
    Dias, Nicholas
    Chen, Yen-Ting
    Li, Sheng
    Zhou, Ping
    Zhang, Yingchun
    JOURNAL OF NEURAL ENGINEERING, 2020, 17 (01)
  • [6] High-density surface electromyography: A visualization method of laryngeal muscle activity
    Bracken, David J.
    Ornelas, Gladys
    Coleman, Todd P.
    Weissbrod, Philip A.
    LARYNGOSCOPE, 2019, 129 (10) : 2347 - 2353
  • [7] A new method for the localization of the innervation zone based on monopolar surface-detected potentials
    Rodriguez-Falces, Javier
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2017, 35 : 47 - 60
  • [8] High-density Surface Electromyography as Biomarker of Muscle Aging
    Imrani, Loubna
    Boudaoud, Sofiane
    Lahaye, Clement
    Moreau, Caroline
    Ghezal, Myriam
    Ben Manaa, Safa
    Doulazmi, Mohamed
    Laforet, Jeremy
    Marin, Frederic
    Kinugawa, Kiyoka
    JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2023, 78 (01): : 25 - 33
  • [9] An investigation into thumb rotation using high density surface electromyography of extrinsic hand muscles
    Aranceta-Garza, A.
    Lakany, H.
    Conway, B. A.
    2013 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC 2013), 2013, : 3751 - 3755
  • [10] Normalised Mutual Information of High-Density Surface Electromyography during Muscle Fatigue
    Bingham, Adrian
    Arjunan, Sridhar P.
    Jelfs, Beth