Operation diagnosis for centrifugal pumps using stator current-based indicators

被引:3
|
作者
Han, Yuejiang [1 ]
Yuan, Jianping [1 ]
Luo, Yin [1 ]
Zou, Jiamin [1 ]
机构
[1] Jiangsu Univ, Natl Res Ctr Pumps, 301 Xuefu Rd, Zhenjiang 212013, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
MCSA; centrifugal pumps; operation evaluation; indicators; harmonic; noise; MOTOR CURRENT SIGNATURE; VIBRATION; CAVITATION;
D O I
10.1177/09544062221126637
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Motor current signature analysis (MCSA) used in the diagnosis of centrifugal pumps has become a hot topic due to its non-intrusive and cost-effective nature. Yet, traditional current-based diagnosis methods show limitations as massive computation and power frequency interference. Moreover, most of them focus on the fault detection, fewer discuss the applications in operation evaluation. Therefore in this article, the hydro-mechanical-electric coupling effect that exists in the induction motor-centrifugal pump system is analyzed systematically. On this foundation, novel indicators that can reflect the harmonic distortion and noise proportion of stator current signals, and further indicate the hydraulic stability and operation status are proposed. Theoretical and experimental analysis support this paper, and results have demonstrated that our proposed indicators can indicate the operation change, identify the optimal operation region, and reflect the development of cavitation for centrifugal pumps. These indicators have the advantages of easy calculation and identification, therefore can be conveniently compared with accepted standards and enable immediate remedial actions to be implemented to ensure the stable operation.
引用
收藏
页码:1075 / 1087
页数:13
相关论文
共 50 条
  • [1] Off-Design Operation and Cavitation Detection in Centrifugal Pumps Using Vibration and Motor Stator Current Analyses
    Han, Yuejiang
    Zou, Jiamin
    Presas, Alexandre
    Luo, Yin
    Yuan, Jianping
    SENSORS, 2024, 24 (11)
  • [2] Unsteady characteristics analysis of centrifugal pump operation based on motor stator current
    Sun, Hui
    Yuan, Shouqi
    Luo, Yin
    Guo, Yihang
    Yin, Jiangnan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2017, 231 (08) : 689 - 705
  • [3] Stator current-based sensorless vibration monitoring of induction motors
    Riley, CM
    Lin, BK
    Habetler, TG
    Kilman, GB
    APEC '97 - TWELFTH ANNUAL APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 2, 1997, : 142 - 147
  • [4] Diagnosis of Centrifugal Pumps using Vibration Analysis
    Minescu, M.
    Pana, I.
    Stan, M.
    OIL GAS-EUROPEAN MAGAZINE, 2015, 41 (04): : 215 - 218
  • [5] Research on stator current characteristics of centrifugal pumps under different mechanical seal failures
    Zou, Jiamin
    Luo, Yin
    Han, Yuejiang
    Fan, Yakun
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2022, 236 (10) : 5748 - 5762
  • [6] Stator current-based bearing fault detection techniques: A general review
    Zhou, Wei
    Habetler, Thomas G.
    Harley, Ronald G.
    2007 IEEE INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS & DRIVES, 2007, : 1 - 4
  • [7] Current-Based Bearing Fault Diagnosis Using Deep Learning Algorithms
    Barcelos, Andre S.
    Cardoso, Antonio J. Marques
    ENERGIES, 2021, 14 (09)
  • [8] Stator current-based locomotive traction motor bearing fault detection
    Yang, Jiang-Tian
    Zhao, Wen-Yu
    Lee, Jay
    Advanced Materials Research, 2013, 819 : 186 - 191
  • [9] Diagnosis of Submersible Centrifugal Pumps: A Motor Current and Power Signature Approaches
    Hernandez-Solis, Augusto
    Carlsson, Fredrik
    EPE JOURNAL, 2010, 20 (01) : 58 - 64
  • [10] Complete current-based induction motor condition monitoring: Stator, rotor, bearings, and load
    Habetler, TG
    Harley, RG
    Tallam, RM
    Lee, SB
    Obaid, R
    Stack, J
    IEEE INTERNATIONAL POWER ELECTRONICS CONGRESS, TECHNICAL PROCEEDINGS, 2002, : 3 - 8